DONATE

Publications

by Keyword: Interaction forces

Obiols-Rabasa, M., Oncins, G., Sanz, F., Tadros, T. F., Solans, C., Levecke, B., Booten, K., Esquena, J., (2017). Investigation of the elastic and adhesion properties of adsorbed hydrophobically modified inulin films on latex particles using Atomic Force Microscopy (AFM) Colloids and Surfaces A: Physicochemical and Engineering Aspects , 524, 185-192

Graft polymer surfactants provide very good colloidal stability because of strong steric repulsions between adsorbed surfactant films. The elastic and adhesion properties of adsorbed hydrophobically modified inulin polymer surfactant (INUTEC NRA) have been directly measured using Atomic Force Microscopy (AFM) measurements. For this purpose, poly(methyl methacrylate/butyl acrylate), P(MMA/BuA), latexes prepared in the presence of the hydrophobically modified inulin (INUTEC NRA) were used. These latexes (diameter 118 nm and polydispersity index of 1.05) showed a very high colloidal stability in water and in the presence of electrolyte (up to 0.2 mol dm−3 KBr). The latexes were deposited on mica, which was silanated to enhance the adhesion of the latex particles to the surface. A silicon nitride tip with approximately 10 nm diameter that also contained an adsorbed layer of surfactant was used in the AFM apparatus. The tip was allowed to approach, contact thereafter the particles with an applied force of 12.5 nN, and finally detach from the film. Both elastic (Young’s) modulus of the film and adhesion force were studied. The results showed that the adsorbed surfactant films are highly elastic and their elastic modulus and adhesion force did not change significantly with the presence of Na2SO4 up to 0.05 mol dm−3. The high elastic contribution to the steric interaction ensures strong repulsion between the latex particles both in water and at high electrolyte concentrations. In addition, the lack of dependence of adhesion force on electrolyte concentration ensures uniform deposition of the latex particles on a flat substrate as for example in coating applications. These results show the advantages of using a graft polymer surfactant for enhancing the stability of particle suspensions, as illustrated in previous investigations.

JTD Keywords: AFM, Colloidal stability, Interaction forces, Steric repulsion


Amigo, L. E., Fernandez, Q., Giralt, X., Casals, A., Amat, J., (2012). Study of patient-orthosis interaction forces in rehabilitation therapies IEEE Conference Publications 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) , IEEE (Roma, Italy) , 1098-1103

The design of mechanical joints that kinematically behave as their biological counterparts is a challenge that if not addressed properly can cause inadequate forces transmission between robot and patient. This paper studies the interaction forces in rehabilitation therapies of the elbow joint. To measure the effect of orthosis-patient misalignments, a force sensor with a novel distributed architecture has been designed and used for this study. A test-bed based on an industrial robot acting as a virtual exoskeleton that emulates the action of a therapist has been developed and the interaction forces analyzed.

JTD Keywords: Force, Force measurement, Force sensors, Joints, Medical treatment, Robot sensing systems, Force sensors, Medical robotics, Patient rehabilitation, Biological counterparts, Distributed architecture, Elbow joint, Force sensor, Inadequate forces transmission, Industrial robot, Mechanical joints design, Orthosis-patient misalignments, Patient-orthosis interaction forces, Rehabilitation therapies, Robot, Test-bed, Virtual exoskeleton