Solórzano, A., Rodríguez-Pérez, R., Padilla, M., Graunke, T., Fernandez, L., Marco, S., Fonollosa, J., (2018). Multi-unit calibration rejects inherent device variability of chemical sensor arrays Sensors and Actuators B: Chemical 265, 142-154

Inherent sensor variability limits mass-production applications for metal oxide (MOX) gas sensor arrays because calibration for replicas of a sensor array needs to be performed individually. Recently, calibration transfer strategies have been proposed to alleviate calibration costs of new replicas, but they still require the acquisition of transfer samples. In this work, we present calibration models that can be extended to uncalibrated replicas of sensor arrays without acquiring new samples, i.e., general or global calibration models. The developed methodology consists in including multiple replicas of a sensor array in the calibration process such that sensor variability is rejected by the general model. Our approach was tested using replicas of a MOX sensor array in the classification task of six gases and synthetic air, presented at different background humidity and concentration levels. Results showed that direct transfer of individual calibration models provides poor classification accuracy. However, we also found that general calibration models kept predictive performance when were applied directly to new copies of the sensor array. Moreover, we explored, through feature selection, whether particular combinations of sensors and operating temperatures can provide predictive performances equivalent to the calibration model with the complete array, favoring thereby the existence of more robust calibration models.

JTD Keywords: Gas sensor array, MOX sensor, Robust calibration, Calibration transfer, Machine olfaction


Fernandez, L., Martin-Gomez, A., Mar Contreras, M., Padilla, M., Marco, S., Arce, L., (2017). Ham quality evaluation assisted by gas chromatography ion mobility spectrometry IEEE Conference Publications ISOCS/IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) , IEEE (Montreal, Canada) , 1-3

In recent years, Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) has been successfully employed in food science as a control technique for the prevention of fraud according to food and labeling regulations. In this work, we propose the use of GC-IMS technique to assess the quality of Iberian ham with regard to the Iberian Pig's diet (either nourished with feed or with acorns). For this purpose, we have acquired a dataset composed of 53 samples of Iberian ham from different food providers using a commercial GC-IMS (FlavourSpec, from G.A.S. Dortmund, Germany). Intensive signal pre-processing for GC-IMS was applied to the raw data. This dataset was employed to create four Partial Least Squares Discriminant Analysis (PLSDA) models corresponding to different train/test partitions of the dataset. Nearly perfect classification rates (above 91 %) were obtained for each partition of the dataset, denoting the high power of GC-IMS to characterize food samples.

JTD Keywords: Classification, Food Science, GC-IMS, Ham quality, PLSDA


Montoliu, I., Tauler, R., Padilla, M., Pardo, A., Marco, S., (2010). Multivariate curve resolution applied to temperature modulated metal oxide gas sensors Sensors and Actuators B: Chemical 145, (1), 464-473

Metal oxide (MOX) gas sensors have been widely used for years. Temperature modulation of gas sensors is as an alternative to increase their sensitivity and selectivity to different gas species. In order to enhance the extraction of useful information from this kind of signals, data processing techniques are needed. In this work, the use of self-modelling curve resolution techniques, in particular multivariate curve resolution-alternating least squares (MCR-ALS), is presented for the analysis of these signals. First, the performance of MCR in a synthetic dataset generated from temperature-modulated gas sensor response models has been evaluated, showing good results both in the resolution of gas mixtures and in the determination of concentration/sensitivity profiles. Secondly, experimental confirmation of previously obtained conclusions is attempted using temperature-modulated MOX sensors together with MCR-ALS for the analysis of carbon monoxide (CO) and methane (CH4) gas mixtures in dry air. Results allow confirming the possibility of using the proposed approach as a quantitative technique for gas mixtures analysis, and also reveal some limitations.

JTD Keywords: Temperature modulation, Multivariate curve resolution, MCR-ALS, Metal oxide sensors


Padilla, M., Perera, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2010). Drift compensation of gas sensor array data by orthogonal signal correction Chemometrics and Intelligent Laboratory Systems , 100, (1), 28-35

Drift is an important issue that impairs the reliability of gas sensing systems. Sensor aging, memory effects and environmental disturbances produce shifts in sensor responses that make initial statistical models for gas or odor recognition useless after a relatively short period (typically few weeks). Frequent recalibrations are needed to preserve system accuracy. However, when recalibrations involve numerous samples they become expensive and laborious. An interesting and lower cost alternative is drift counteraction by signal processing techniques. Orthogonal Signal Correction (OSC) is proposed for drift compensation in chemical sensor arrays. The performance of OSC is also compared with Component Correction (CC). A simple classification algorithm has been employed for assessing the performance of the algorithms on a dataset composed by measurements of three analytes using an array of seventeen conductive polymer gas sensors over a ten month period.

JTD Keywords: Gas sensor array, Drift, Orthogonal signal correction, Component correction, Cross-validation, Electronic nose, Data shift


Padilla, M., Perera, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2010). Fault detection, identification, and reconstruction of faulty chemical gas sensors under drift conditions, using Principal Component Analysis and Multiscale-PCA Theoretical or Mathematical; Experimental The 2010 International Joint Conference on Neural Networks (IJCNN 2010) , IEEE, Piscataway, NJ, USA (Barcelona, Spain) , 7 pp.

Statistical methods like Principal Components Analysis (PCA) or Partial Least Squares (PLS) and multiscale approaches, have been reported to be very useful in the task of fault diagnosis of malfunctioning sensors for several types of faults. In this work, we compare the performance of PCA and Multiscale-PCA on a fault based on a change of sensor sensitivity. This type of fault affects chemical gas sensors and it is one of the effects of the sensor poisoning. These two methods will be applied on a dataset composed by the signals of 17 conductive polymer gas sensors, measuring three analytes at several concentration levels during 10 months. Therefore, additionally to performance's comparison, both method's stability along the time will be tested. The comparison between both techniques will be made regarding three aspects; detection, identification of the faulty sensors and correction of faulty sensors response.

JTD Keywords: Fault diagnosis, Gas sensors, Principal component analysis


Padilla, M., Pereral, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2009). Improving drift correction by double projection preprocessing in gas sensor arrays Olfaction Electronic Nose: Proceedings of the 13th International Symposium on Olfaction and Electronic Nose 13th International Symposium on Olfaction and the Electronic Nose (ed. Pardo, M., Sberveglieri, G.), Amer Inst Physics (Brescia, Italy) 1137, 101-104

It is well known that gas chemical sensors are strongly affected by drift. Drift consist on changes in sensors responses along the time, which make that initial statistical models for gas or odor recognition become useless after a period of time of about weeks. Gas sensor arrays based instruments periodically need calibrations that are expensive and laborious. Many different statistical methods have been proposed to extend time between recalibrations. In this work, a simple preprocessing technique based on a double projection is proposed as a prior step to a posterior drift correction algorithm (in this particular case, Direct Orthogonal Signal Correction). This method highly improves the time stability of data in relation with the one obtained by using only such drift correction method. The performance of this technique will be evaluated on a dataset composed by measurements of three analytes by a polymer sensor array along ten months.

JTD Keywords: Drift, Direct orthogonal signal correction