DONATE

Publications

by Keyword: Gas sensor array

Solórzano, A., Rodríguez-Pérez, R., Padilla, M., Graunke, T., Fernandez, L., Marco, S., Fonollosa, J., (2018). Multi-unit calibration rejects inherent device variability of chemical sensor arrays Sensors and Actuators B: Chemical 265, 142-154

Inherent sensor variability limits mass-production applications for metal oxide (MOX) gas sensor arrays because calibration for replicas of a sensor array needs to be performed individually. Recently, calibration transfer strategies have been proposed to alleviate calibration costs of new replicas, but they still require the acquisition of transfer samples. In this work, we present calibration models that can be extended to uncalibrated replicas of sensor arrays without acquiring new samples, i.e., general or global calibration models. The developed methodology consists in including multiple replicas of a sensor array in the calibration process such that sensor variability is rejected by the general model. Our approach was tested using replicas of a MOX sensor array in the classification task of six gases and synthetic air, presented at different background humidity and concentration levels. Results showed that direct transfer of individual calibration models provides poor classification accuracy. However, we also found that general calibration models kept predictive performance when were applied directly to new copies of the sensor array. Moreover, we explored, through feature selection, whether particular combinations of sensors and operating temperatures can provide predictive performances equivalent to the calibration model with the complete array, favoring thereby the existence of more robust calibration models.

JTD Keywords: Gas sensor array, MOX sensor, Robust calibration, Calibration transfer, Machine olfaction


Fernandez, L., Yan, J., Fonollosa, J., Burgués, J., Gutierrez, A., Marco, S., (2018). A practical method to estimate the resolving power of a chemical sensor array: Application to feature selection Frontiers in Chemistry 6, Article 209

A methodology to calculate analytical figures of merit is not well established for detection systems that are based on sensor arrays with low sensor selectivity. In this work, we present a practical approach to estimate the Resolving Power of a sensory system, considering non-linear sensors and heteroscedastic sensor noise. We use the definition introduced by Shannon in the field of communication theory to quantify the number of symbols in a noisy environment, and its version adapted by Gardner and Barlett for chemical sensor systems. Our method combines dimensionality reduction and the use of algorithms to compute the convex hull of the empirical data to estimate the data volume in the sensor response space. We validate our methodology with synthetic data and with actual data captured with temperature-modulated MOX gas sensors. Unlike other methodologies, our method does not require the intrinsic dimensionality of the sensor response to be smaller than the dimensionality of the input space. Moreover, our method circumvents the problem to obtain the sensitivity matrix, which usually is not known. Hence, our method is able to successfully compute the Resolving Power of actual chemical sensor arrays. We provide a relevant figure of merit, and a methodology to calculate it, that was missing in the literature to benchmark broad-response gas sensor arrays.

JTD Keywords: Gas sensor array, MOX sensors, Resolving Power, Sensor resolution, Dimensionality reduction, Machine olfaction


Solorzano, A., Fonollosa, J., Fernandez, L., Eichmann, J., Marco, S., (2017). Fire detection using a gas sensor array with sensor fusion algorithms IEEE Conference Publications ISOCS/IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) , IEEE (Montreal, Canada) , 1-3

Conventional fire alarms are based on smoke detection. Nevertheless, in some fire scenarios volatiles are released before smoke. Fire detectors based only on chemical sensors have already been proposed as they may provide faster response, but they are still prone to false alarms in the presence of nuisances. These systems rely heavily on pattern recognition techniques to discriminate fires from nuisances. In this context, it is important to test the systems according to international standards for fires and testing the system against a diversity of nuisances. In this work, we investigate the behavior of a gas sensor array coupled to sensor fusion algorithms for fire detection when exposed to standardized fires and several nuisances. Results confirmed the ability to detect fires (97% Sensitivity), although the system still produces a significant rate of false alarms (35%) for nuisances not presented in the training set.

JTD Keywords: Fire alarm, Gas sensor array, Machine Olfaction, Multisensor system, Sensor fusion


Fernandez, L., Guney, S., Gutierrez-Galvez, A., Marco, S., (2016). Calibration transfer in temperature modulated gas sensor arrays Sensors and Actuators B: Chemical 231, 276-284

Abstract Shifts in working temperature are an important issue that prevents the successful transfer of calibration models from one chemical instrument to another. This effect is of special relevance when working with gas sensor arrays modulated in temperature. In this paper, we study the use of multivariate techniques to transfer the calibration model from a temperature modulated gas sensor array to another when a global change of temperature occurs. To do so, we built 12 identical master sensor arrays composed of three different types of commercial Figaro sensors and acquired a dataset of sensor responses to three pure substances (ethanol, acetone and butanone) dosed at 7 concentrations. The master arrays are then shifted in temperature (from −50 to 50 °C, ΔT = 10 °C) and considered as slave arrays. Data correction is performed for an increasing number of transfer samples with 4 different calibration transfer techniques: Direct Standardization, Piece-wise Direct Standardization, Orthogonal Signal Correction and Generalized Least Squares Weighting. In order to evaluate the performance of the calibration transfer, we compare the Root Mean Square Error of Prediction (RMSEP) of master and slave arrays, for each instrument correction. Best results are obtained from Piece-wise Direct standardization, which exhibits the lower RMSEP values after correction for the smaller number of transfer samples.

JTD Keywords: Calibration transfer, Gas sensor array, MOX, Temperature modulation


Ziyatdinov, Andrey, Fonollosa, Jordi, Fernández, Luis, Gutiérrez-Gálvez, Agustín, Marco, Santiago, Perera, Alexandre, (2015). Data set from gas sensor array under flow modulation Data in Brief 3, 131-136

Abstract Recent studies in neuroscience suggest that sniffing, namely sampling odors actively, plays an important role in olfactory system, especially in certain scenarios such as novel odorant detection. While the computational advantages of high frequency sampling have not been yet elucidated, here, in order to motivate further investigation in active sampling strategies, we share the data from an artificial olfactory system made of 16 MOX gas sensors under gas flow modulation. The data were acquired on a custom set up featured by an external mechanical ventilator that emulates the biological respiration cycle. 58 samples were recorded in response to a relatively broad set of 12 gas classes, defined from different binary mixtures of acetone and ethanol in air. The acquired time series show two dominant frequency bands: the low-frequency signal corresponds to a conventional response curve of a sensor in response to a gas pulse, and the high-frequency signal has a clear principal harmonic at the respiration frequency. The data are related to the study in [1], and the data analysis results reported there should be considered as a reference point.

JTD Keywords: Gas sensor array, MOX sensor, Flow modulation, Early detection, Biomimetics, Respiration, Sniffing


Ziyatdinov, Andrey, Fonollosa, Jordi, Fernánndez, Luis, Gutierrez-Gálvez, Agustín, Marco, Santiago, Perera, Alexandre, (2015). Bioinspired early detection through gas flow modulation in chemo-sensory systems Sensors and Actuators B: Chemical 206, 538-547

Abstract The design of bioinspired systems for chemical sensing is an engaging line of research in machine olfaction. Developments in this line could increase the lifetime and sensitivity of artificial chemo-sensory systems. Such approach is based on the sensory systems known in live organisms, and the resulting developed artificial systems are targeted to reproduce the biological mechanisms to some extent. Sniffing behaviour, sampling odours actively, has been studied recently in neuroscience, and it has been suggested that the respiration frequency is an important parameter of the olfactory system, since the odour perception, especially in complex scenarios such as novel odourants exploration, depends on both the stimulus identity and the sampling method. In this work we propose a chemical sensing system based on an array of 16 metal-oxide gas sensors that we combined with an external mechanical ventilator to simulate the biological respiration cycle. The tested gas classes formed a relatively broad combination of two analytes, acetone and ethanol, in binary mixtures. Two sets of low-frequency and high-frequency features were extracted from the acquired signals to show that the high-frequency features contain information related to the gas class. In addition, such information is available at early stages of the measurement, which could make the technique suitable in early detection scenarios. The full data set is made publicly available to the community.11 http://archive.ics.uci.edu/ml/datasets/Gas+sensor+array+under+flow+modulation.

JTD Keywords: Gas sensor array, MOX sensor, Flow modulation, Early detection, Biomimetics, Sniffing


Fernandez, L., Marco, S., Gutierrez-Galvez, A., (2015). Robustness to sensor damage of a highly redundant gas sensor array Sensors and Actuators B: Chemical 218, 296-302

Abstract In this paper we study the role of redundant sensory information to prevent the performance degradation of a chemical sensor array for different distributions of sensor failures across sensor types. The large amount of sensing conditions with two different types of redundancy provided by our sensor array makes possible a comprehensive experimental study. Particularly, our sensor array is composed of 8 different types of commercial MOX sensors modulated in temperature with two redundancy levels: (1) 12 replicates of each sensor type for a total of 96 sensors and (2) measurements using 16 load resistors per sensors for a total of 1536 redundant measures per second. We perform two experiments to determine the performance degradation of the array with increasing number of damaged sensors in two different scenarios of sensor faults distributions across sensor types. In the first experiment, we characterize the diversity and redundancy of the array for increasing number of damaged sensors. To measure diversity and redundancy, we proposed a functional definition based on clustering of sensor features. The second experiment is devoted to determine the performance degradation of the array for the effect of faulty sensors. To this end, the system is trained to separate ethanol, acetone and butanone at different concentrations using a PCA–LDA model. Test set samples are corrupted by means of three different simulated types of faults. To evaluate the performance of the array we used the Fisher score as a measure of odour separability. Our results show that to exploit to the utmost the redundancy of the sensor array faulty sensory units have to be distributed uniformly across the different sensor types.

JTD Keywords: Gas sensor arrays, Sensor redundancy, Sensor diversity, Sensor faults aging, Sensor damage, MOX sensors, Large sensor arrays


Ziyatdinov, A., Diaz, E. Fernández, Chaudry, A., Marco, S., Persaud, K., Perera, A., (2013). A software tool for large-scale synthetic experiments based on polymeric sensor arrays Sensors and Actuators B: Chemical 177, 596-604

This manuscript introduces a software tool that allows for the design of synthetic experiments in machine olfaction. The proposed software package includes both, a virtual sensor array that reproduces the diversity and response of a polymer array and tools for data generation. The synthetic array of sensors allows for the generation of chemosensor data with a variety of characteristics: unlimited number of sensors, support of multicomponent gas mixtures and full parametric control of the noise in the system. The artificial sensor array is inspired from a reference database of seventeen polymeric sensors with concentration profiles for three analytes. The main features in the sensor data, like sensitivity, diversity, drift and sensor noise, are captured by a set of models under simplified assumptions. The generator of sensor signals can be used in applications related to test and benchmarking of signal processing methods, neuromorphic simulations in machine olfaction and educational tools. The software is implemented in R language and can be freely accessed.

JTD Keywords: Gas Sensor Array, Conducting Polymers, Electronic Nose, Sensor Simulation, Synthetic Dataset, Benchmark, Educational Tool


Ziyatdinov, A., Marco, S., Chaudry, A., Persaud, K., Caminal, P., Perera, A., (2010). Drift compensation of gas sensor array data by common principal component analysis Sensors and Actuators B: Chemical 146, (2), 460-465

A new drift compensation method based on Common Principal Component Analysis (CPCA) is proposed. The drift variance in data is found as the principal components computed by CPCA. This method finds components that are common for all gasses in feature space. The method is compared in classification task with respect to the other approaches published where the drift direction is estimated through a Principal Component Analysis (PCA) of a reference gas. The proposed new method - employing no specific reference gas, but information from all gases -has shown the same performance as the traditional approach with the best-fitted reference gas. Results are shown with data lasting 7-months including three gases at different concentrations for an array of 17 polymeric sensors.

JTD Keywords: Gas sensor array, Drift, Common principal component, Analysis, Component correction, Electronic nose


Padilla, M., Perera, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2010). Drift compensation of gas sensor array data by orthogonal signal correction Chemometrics and Intelligent Laboratory Systems , 100, (1), 28-35

Drift is an important issue that impairs the reliability of gas sensing systems. Sensor aging, memory effects and environmental disturbances produce shifts in sensor responses that make initial statistical models for gas or odor recognition useless after a relatively short period (typically few weeks). Frequent recalibrations are needed to preserve system accuracy. However, when recalibrations involve numerous samples they become expensive and laborious. An interesting and lower cost alternative is drift counteraction by signal processing techniques. Orthogonal Signal Correction (OSC) is proposed for drift compensation in chemical sensor arrays. The performance of OSC is also compared with Component Correction (CC). A simple classification algorithm has been employed for assessing the performance of the algorithms on a dataset composed by measurements of three analytes using an array of seventeen conductive polymer gas sensors over a ten month period.

JTD Keywords: Gas sensor array, Drift, Orthogonal signal correction, Component correction, Cross-validation, Electronic nose, Data shift


Fernandez, L., Gutierrez-Galvez, A., Marco, S., (2010). Gas sensor array system inspired on the sensory diversity and redundancy of the olfactory epithelium Procedia Engineering Eurosensor XXIV Conference (ed. Jakoby, B., Vellekoop, M.J.), Elsevier Science BV (Linz, Austria) 5, (0), 25-28

This paper presents a chemical sensing system that takes inspiration from the combination of sensory diversity and redundancy at the olfactory epithelium to enhance the chemical information obtained from the odorants. The system is based on commercial MOS sensors and achieves, first, diversity trough different types of MOS along with modulation of their temperatures, and second redundancy including 12 MOS sensors for each type (12×8) combined with a high-speed multiplexing system that allows connecting 16 load resistors with each and every one of the 96 sensors in about two seconds. Exposition of the system to ethanol, ammonia, and acetone at different concentrations shows how the system is able to capture a large amount of information of the identity and the concentration of the odorant.

JTD Keywords: Gas sensor array, Biologically inspired system, Redundancy, Diversity, MOX sensors, Temperature modulation