Inherent sensor variability limits mass-production applications for metal oxide (MOX) gas sensor arrays because calibration for replicas of a sensor array needs to be performed individually. Recently, calibration transfer strategies have been proposed to alleviate calibration costs of new replicas, but they still require the acquisition of transfer samples. In this work, we present calibration models that can be extended to uncalibrated replicas of sensor arrays without acquiring new samples, i.e., general or global calibration models. The developed methodology consists in including multiple replicas of a sensor array in the calibration process such that sensor variability is rejected by the general model. Our approach was tested using replicas of a MOX sensor array in the classification task of six gases and synthetic air, presented at different background humidity and concentration levels. Results showed that direct transfer of individual calibration models provides poor classification accuracy. However, we also found that general calibration models kept predictive performance when were applied directly to new copies of the sensor array. Moreover, we explored, through feature selection, whether particular combinations of sensors and operating temperatures can provide predictive performances equivalent to the calibration model with the complete array, favoring thereby the existence of more robust calibration models.
In recent years, Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) has been successfully employed in food science as a control technique for the prevention of fraud according to food and labeling regulations. In this work, we propose the use of GC-IMS technique to assess the quality of Iberian ham with regard to the Iberian Pig's diet (either nourished with feed or with acorns). For this purpose, we have acquired a dataset composed of 53 samples of Iberian ham from different food providers using a commercial GC-IMS (FlavourSpec, from G.A.S. Dortmund, Germany). Intensive signal pre-processing for GC-IMS was applied to the raw data. This dataset was employed to create four Partial Least Squares Discriminant Analysis (PLSDA) models corresponding to different train/test partitions of the dataset. Nearly perfect classification rates (above 91 %) were obtained for each partition of the dataset, denoting the high power of GC-IMS to characterize food samples.
Metal oxide (MOX) gas sensors have been widely used for years. Temperature modulation of gas sensors is as an alternative to increase their sensitivity and selectivity to different gas species. In order to enhance the extraction of useful information from this kind of signals, data processing techniques are needed. In this work, the use of self-modelling curve resolution techniques, in particular multivariate curve resolution-alternating least squares (MCR-ALS), is presented for the analysis of these signals. First, the performance of MCR in a synthetic dataset generated from temperature-modulated gas sensor response models has been evaluated, showing good results both in the resolution of gas mixtures and in the determination of concentration/sensitivity profiles. Secondly, experimental confirmation of previously obtained conclusions is attempted using temperature-modulated MOX sensors together with MCR-ALS for the analysis of carbon monoxide (CO) and methane (CH4) gas mixtures in dry air. Results allow confirming the possibility of using the proposed approach as a quantitative technique for gas mixtures analysis, and also reveal some limitations.
Drift is an important issue that impairs the reliability of gas sensing systems. Sensor aging, memory effects and environmental disturbances produce shifts in sensor responses that make initial statistical models for gas or odor recognition useless after a relatively short period (typically few weeks). Frequent recalibrations are needed to preserve system accuracy. However, when recalibrations involve numerous samples they become expensive and laborious. An interesting and lower cost alternative is drift counteraction by signal processing techniques. Orthogonal Signal Correction (OSC) is proposed for drift compensation in chemical sensor arrays. The performance of OSC is also compared with Component Correction (CC). A simple classification algorithm has been employed for assessing the performance of the algorithms on a dataset composed by measurements of three analytes using an array of seventeen conductive polymer gas sensors over a ten month period.
Statistical methods like Principal Components Analysis (PCA) or Partial Least Squares (PLS) and multiscale approaches, have been reported to be very useful in the task of fault diagnosis of malfunctioning sensors for several types of faults. In this work, we compare the performance of PCA and Multiscale-PCA on a fault based on a change of sensor sensitivity. This type of fault affects chemical gas sensors and it is one of the effects of the sensor poisoning. These two methods will be applied on a dataset composed by the signals of 17 conductive polymer gas sensors, measuring three analytes at several concentration levels during 10 months. Therefore, additionally to performance's comparison, both method's stability along the time will be tested. The comparison between both techniques will be made regarding three aspects; detection, identification of the faulty sensors and correction of faulty sensors response.
Padilla, M., Pereral, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2009). Improving drift correction by double projection preprocessing in gas sensor arraysOlfaction Electronic Nose: Proceedings of the 13th International Symposium on Olfaction and Electronic Nose 13th International Symposium on Olfaction and the Electronic Nose (ed. Pardo, M., Sberveglieri, G.), Amer Inst Physics (Brescia, Italy) 1137, 101-104
It is well known that gas chemical sensors are strongly affected by drift. Drift consist on changes in sensors responses along the time, which make that initial statistical models for gas or odor recognition become useless after a period of time of about weeks. Gas sensor arrays based instruments periodically need calibrations that are expensive and laborious. Many different statistical methods have been proposed to extend time between recalibrations. In this work, a simple preprocessing technique based on a double projection is proposed as a prior step to a posterior drift correction algorithm (in this particular case, Direct Orthogonal Signal Correction). This method highly improves the time stability of data in relation with the one obtained by using only such drift correction method. The performance of this technique will be evaluated on a dataset composed by measurements of three analytes by a polymer sensor array along ten months.
Les cookies són importants per a tu, influeixen en la teva experiència de navegació, ens ajuden a protegir la teva privacitat i permeten realitzar les sol·licituds que ens facis a través del web. Utilitzem cookies pròpies i de tercers per analitzar els nostres serveis i mostrar-te publicitat relacionada amb les teves preferències, basada en un perfil elaborat a partir dels teus hàbits de navegació. Pots «Acceptar» o «Rebutjar» aquelles cookies que no siguin tècniques, així com configurar les teves preferències prement «Configurar cookies». Per a més informació, consulta la nostra Política de Cookies.
Funcionals
Sempre actiu
l’emmagatzematge o l’accés tècnic és estrictament necessari per a la finalitat legítima de permetre l’ús d’un servei específic sol·licitat explícitament pel subscriptor o l’usuari, o amb l’únic objectiu de dur a terme la transmissió d’una comunicació a través d’una xarxa de comunicacions electròniques.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.L’emmagatzematge o l’accés tècnic que s’utilitza exclusivament amb finalitats estadístiques anònimes. Sense una ordre judicial, el compliment voluntari per part del seu proveïdor de serveis d’Internet, o registres addicionals d’un tercer, la informació emmagatzemada o recuperada amb aquesta única finalitat no es pot utilitzar normalment per identificar-lo.
Marketing
L’emmagatzematge o l’accés tècnic és necessari per crear perfils d’usuari amb la finalitat d’enviar publicitat, o per fer el seguiment de l’usuari en un lloc web o en diversos llocs web amb finalitats de màrqueting similars.