by Keyword: hemocompatibility
Witzdam, Lena, White, Tom, Rodriguez-Emmenegger, Cesar, (2024). Steps Toward Recapitulating Endothelium: A Perspective on the Next Generation of Hemocompatible Coatings Macromolecular Bioscience 24, 2400152
Endothelium, the lining in this blood vessel, orchestrates three main critical functions such as protecting blood components, modulating of hemostasis by secreting various inhibitors, and directing clot digestion (fibrinolysis) by activating tissue plasminogen activator. No other surface can perform these tasks; thus, the contact of blood and blood-contacting medical devices inevitably leads to the activation of coagulation, often causing device failure, and thromboembolic complications. This perspective, first, discusses the biological mechanisms of activation of coagulation and highlights the efforts of advanced coatings to recapitulate one characteristic of endothelium, hereafter single functions of endothelium and noting necessity of the synergistic integration of its three main functions. Subsequently, it is emphasized that to overcome the challenges of blood compatibility an endothelium-mimicking system is needed, proposing a synergy of bottom-up synthetic biology, particularly synthetic cells, with passive- and bioactive surface coatings. Such integration holds promise for developing advanced biomaterials capable of recapitulating endothelial functions, thereby enhancing the hemocompatibility and performance of blood-contacting medical devices. The activation of coagulation on the surface of blood-contacting medical devices often leads to thromboembolic complications. A concept for the next generation of hemocompatbile surfaces inspired by endothelium is proposed. This concept not only contribute to the fundamental understanding of hemocompatibility but also offer practical implications for the design and development of biomedical devices with enhanced biocompatibility and functionality. image
JTD Keywords: Antifouling coatings, Antifouling polymer brushes, Coagulation-factor-xii, Endothelium-inspired, Hemocompatibility, Hemocompatible surface coatings, Heparin-induced thrombocytopenia, Nitric-oxide release, Of-the-art, Peptide macrocycle inhibitor, Plasma contact system, Protein-adsorption, Self-assembled monolayers, Surface modificatio, Synthetic endotheliu
Witzdam, L, Vosberg, B, Grosse-Berkenbusch, K, Stoppelkamp, S, Wendel, HP, Rodriguez-Emmenegger, C, (2024). Tackling the Root Cause of Surface-Induced Coagulation: Inhibition of FXII Activation to Mitigate Coagulation Propagation and Prevent Clotting Macromolecular Bioscience 24, e2300321
Factor XII (FXII) is a zymogen present in blood that tends to adsorb onto the surfaces of blood-contacting medical devices. Once adsorbed, it becomes activated, initiating a cascade of enzymatic reactions that lead to surface-induced coagulation. This process is characterized by multiple redundancies, making it extremely challenging to prevent clot formation and preserve the properties of the surface. In this study, a novel modulatory coating system based on C1-esterase inhibitor (C1INH) functionalized polymer brushes, which effectively regulates the activation of FXII is proposed. Using surface plasmon resonance it is demonstrated that this coating system effectively repels blood plasma proteins, including FXII, while exhibiting high activity against activated FXII and plasma kallikrein under physiological conditions. This unique property enables the modulation of FXII activation without interfering with the overall hemostasis process. Furthermore, through dynamic Chandler loop studies, it is shown that this coating significantly improves the hemocompatibility of polymeric surfaces commonly used in medical devices. By addressing the root cause of contact activation, the synergistic interplay between the antifouling polymer brushes and the modulatory C1INH is expected to lay the foundation to enhance the hemocompatibility of medical device surfaces.© 2023 The Authors. Macromolecular Bioscience published by Wiley-VCH GmbH.
JTD Keywords: adsorption, binding, c1-esterase-inhibitor, coatings, contact activation, factor-xii, fxii activation, hemocompatibility, hemocompatible surface modification, heparin, polymer brushes, system, thrombosis, Adsorption, Anticoagulation, Antifouling agent, Article, Beta-fxiia, Biocompatibility, Blood, Blood clotting, Blood clotting factor 12, Blood clotting factor 12a, Blood clotting factor 12a inhibitor, Blood coagulation, C1-esterase-inhibitor, Cell activation, Chemical activation, Coagulation, Coating (procedure), Complement component c1s inhibitor, Complement system, Controlled study, Dendrimers, Enzyme immobilization, Enzymes, Erythrocyte, Esters, Factor xii, Factor xii activation, Factor xiia, Fibrin deposition, Functional polymers, Fxii activation, Haemocompatibility, Hemocompatibility, Hemocompatible surface modification, Hemostasis, Heparin, Human, Hydrogel, Medical devices, Metabolism, Plasma kallikrein, Plasma protein, Plastic coatings, Platelet count, Polymer, Polymer brushes, Polymerization, Polymers, Property, Root cause, Surface plasmon resonance, Surface property, Surface reactions, Surface-modification, Thrombocyte adhesion, Β-fxiia
Chausse, V, Mas-Moruno, C, Martin-Gómez, H, Pino, M, Díaz-Ricart, M, Escolar, G, Ginebra, MP, Pegueroles, M, (2023). Functionalization of 3D printed polymeric bioresorbable stents with a dual cell-adhesive peptidic platform combining RGDS and YIGSR sequences Biomaterials Science 11, 4602-4615
The functionalization of 3D-printed poly-l-lactic acid (PLLA) and poly(l-lactic-co-ε-caprolactone) (PLCL) bioresorbable stents has been successfully achieved with linear RGDS and YIGSR peptides, as well as a dual platform containing both motifs within a single biomolecule.
JTD Keywords: adsorbed fibrinogen, chemistry, endothelialization, immobilization, platelets, plla, selectivity, surface, titanium, Absorbable implants, Cell adhesion, Endothelial cells, In-vitro hemocompatibility, Peptides, Polymers, Printing, three-dimensional, Stents, Tyrosyl-isoleucyl-glycyl-seryl-arginine
Quandt, J, Garay-Sarmiento, M, Witzdam, L, Englert, J, Rutsch, Y, Stöcker, C, Obstals, F, Grottke, O, Rodriguez-Emmenegger, C, (2022). Interactive Hemocompatible Nanocoating to Prevent SurfaceInduced Coagulation in Medical Devices Advanced Materials Interfaces 9, 2201055
JTD Keywords: anti-fxiia antibody, artificial surfaces, blood compatibility, complement activation, factor xii, fibrinolytic system, hemocompatible coatings, interactive hemocompatibility, poly(2-methacryloyloxyethyl phosphorylcholine), polyethylene oxide, polymer brushes, radical polymerization, sequential coimmobilization, Antifouling polymer brushes, Protein adsorption
Riedelová, Z, Pereira, AD, Svoboda, J, Pop-Georgievski, O, Májek, P, Pecánková, K, Dycka, F, Rodriguez-Emmenegger, C, Riedel, T, (2022). The Relation Between Protein Adsorption and Hemocompatibility of Antifouling Polymer Brushes Macromolecular Bioscience 22, 2200247
Whenever an artificial surface comes into contact with blood, proteins are rapidly adsorbed onto its surface. This phenomenon, termed fouling, is then followed by a series of undesired reactions involving activation of complement or the coagulation cascade and adhesion of leukocytes and platelets leading to thrombus formation. Thus, considerable efforts are directed towards the preparation of fouling-resistant surfaces with the best possible hemocompatibility. Herein, a comprehensive hemocompatibility study after heparinized blood contact with seven polymer brushes prepared by surface-initiated atom transfer radical polymerization is reported. The resistance to fouling is quantified and thrombus formation and deposition of blood cellular components on the coatings are analyzed. Moreover, identification of the remaining adsorbed proteins is performed via mass spectroscopy to elucidate their influence on the surface hemocompatibility. Compared with an unmodified glass surface, the grafting of polymer brushes minimizes the adhesion of platelets and leukocytes and prevents the thrombus formation. The fouling from undiluted blood plasma is reduced by up to 99%. Most of the identified proteins are connected with the initial events of foreign body reaction towards biomaterial (coagulation cascade proteins, complement component, and inflammatory proteins). In addition, several proteins that are not previously linked with blood-biomaterial interaction are presented and discussed.
JTD Keywords: antifouling surfaces, biosensor, blood-plasma, coagulation, coatings, compatibility, glycoprotein, hemocompatibility, identification, methacrylate), ms identification, polymer brushes, protein adsorption, surface-chemistry, Antifouling surfaces, High-density-lipoprotein, Protein adsorption