Access IBEC scientific production portal (IBEC CRIS), for more detailed information and advanced search features.
Find here the list of all IBEC's publications by year.
by Keyword: Alloys
Celles, Cicero Andrade Sigiliao, Aparicio, Conrado, Barao, Valentim Adelino Ricardo, Dini, Caroline, (2025). Magnesium-Doped Coatings as a Suitable Approach to Improve Osseointegration of Titanium-Based Implants: A Systematic Review and Meta-Analyses of Animal Studies JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS 113, e35681
This review evaluates the effect of magnesium (Mg)-doped coatings on the osseointegration of titanium (Ti)-based implants. The recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and the PRISMA 2020 Statement were followed, with registration in PROSPERO (CRD42024572571). The PICOS strategy was based on population: dental implants; intervention: Mg coatings; control: surfaces without Mg; outcomes: bone-implant contact (BIC), bone area (BA), implant stability coefficient (ISQ), and removal torque (RTQ); and study Design: in vivo studies. The SYRCLE tool was used to assess the risk of bias of animal studies. Meta-analyses were performed, using a random-effect model and 95% confidence interval. Twenty-three records were included, and 21 were enrolled in the meta-analyses. The most commonly used Mg doping method was microarc oxidation. The Mg-doped coatings, significantly favored pooled BIC values in animals [-6.09 (-8.35, -3.82), I-2: 50%, p < 0.00001], especially up to 3, 4, 6, and 8 weeks compared to surfaces without Mg. Interestingly, Mg-doped coatings favored BA up to 6 weeks [-8.20 (-14.31, -2.09), I-2: 0%, p = 0.008], and RTQ up to 3 [-8.44 (-12.33, -4.56), I-2: 63%, p < 0.0001]. Conversely, it did not influence ISQ [-0.24 (-2.05, 1.58), I-2: 88%, p = 0.80]. Mg-doped coatings significantly enhanced osseointegration in dental implants by improving BIC, BA, and RTQ, while showing no impact on ISQ. Supported by studies across various animal species, these results confirm that such coatings represent an effective and safe approach for promoting bone integration.
JTD Keywords: Alloys, Bone, Bone-implant interface, Dental implant, Dental implants, Expression, Incorporated oxidized implants, Ion-implantation, Magnesium, Mg, Osseointegration, Resonance frequency measurements, Strength, Surface-chemistry
García-Mintegui, C, Chausse, V, Labay, C, Mas-Moruno, C, Ginebra, MP, Cortina, JL, Pegueroles, M, (2024). Dual peptide functionalization of Zn alloys to enhance endothelialization for cardiovascular applications APPLIED SURFACE SCIENCE 645, 158900
A new generation of fully bioresorbable metallic Zn-based alloys could be used for stenting applications; however, the initial surface degradation delays stent re-endothelialization. Thus, this work proposes a dual strategy to control the corrosion and accelerate the endothelialization of ZnMg and ZnAg biodegradable alloys. First, a stable polycaprolactone (PCL) coating is obtained and followed by its functionalization with either linear RGD (Arg-Gly-Asp) or REDV (Arg-Glu-Asp-Val) peptides or a dual peptide-based platform combining both sequences (RGD-REDV). Scratching tests showed neither delamination nor detachment of the polymeric coating. Potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) measurements confirmed the corrosion resistance after PCL coating by revealing lower current density and higher absolute impedance values. X-ray photoelectron spectroscopy (XPS) and fluorescent microscopy confirmed the correct peptide immobilization onto PCL coated Zn alloys. The functionalized samples exhibited enhanced human umbilical vein endothelial cells (HUVEC) adhesion. The higher number of adhered cells to the functionalized surfaces with the RGD-REDV platform demonstrates the synergistic effect of combining both RGD and REDV sequences. Higher corrosion resistance together with enhanced endothelialization indicates that the dual functionalization of Zn alloys with PCL and peptide-based RGD-REDV platform holds great potential to overcome the clinical limitations of current biodegradable metal stents.
JTD Keywords: Binary alloys, Biodegradable metals, Bioresorbable, Cardiovascular applications, Cell adhesive peptides, Corrosion, Corrosion resistance, Corrosion resistant alloys, Corrosion resistant coatings, Degradation, Dual peptide-based platform, Electrochemical corrosion, Electrochemical impedance spectroscopy, Endothelial cells, Endothelialization, Functionalization, Functionalizations, In-vitro, Magnesium alloys, Metallics, Mg alloy, Peptides, Polycaprolactone coating, Polymer-coatings, Rgd-functionalization, Silver alloys, Stents, Surface, X ray photoelectron spectroscopy, Zinc, Zinc alloys, Zn alloys, Zn-based alloys
Claudia, GM, Ivan, G, Laia, OM, Emilio, JP, Maria-Pau, G, Maurizio, V, Luis, CJ, Marta, P, (2023). Influence of ECAP process on mechanical, corrosion and bacterial properties of Zn-2Ag alloy for wound closure devices MATERIALS & DESIGN 228, 111817
Actual polymeric wound closure devices are not optimal for load-bearing applications due to the low mechanical properties and the risk of inflammation and bacterial infection mainly produced by multifil-ament and braided configurations. Biodegradable metallic Zn alloys are promising materials candidates; however, mechanical performance, corrosion behaviour, and biological response should be controlled in order to inhibit the risk of inflammation and bacterial infection. To this end, a Zn-2Ag (2 wt% Ag) alloy was processed by ECAP to evaluate the concurrent combined effect of grain refinement and Ag alloying on biodegradation and antibacterial activity. Two ECAP cycles were successfully applied to a Zn-2Ag alloy obtaining a homogeneous ultra-fine-grained structure in which nanoindentation maps suggested isotro-pic mechanical properties. Lower UTS and YS with higher elongation was reported after ECAP with similar corrosion rates as before processing. ECAP processed samples showed a homogeneous Ag+ release below the minimum inhibitory concentration for S. Aureus and no antibacterial effect was observed by diffusion. As expected, the presence of Ag in Zn-Ag alloys reduced bacterial attachment. Nevertheless, ECAP processed Zn-2Ag provided an excellent antibacterial activity after 3 h probably caused by the uniformly degraded and thus, non- stable, surface observed after bacterial adhesion.(c) 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
JTD Keywords: Behavior, Binary alloys, Biodegradable zinc-alloys, Biomaterials, Equal channel angular pressing, Grain-refinement, In-vitro degradation, Mg, Microstructure, Nanoindentation, Progress, Staphylococcus-aureus, Temperature superplasticity, Ultrafine-grained materials, Zinc alloys, Zn alloys
García-Mintegui, C, Córdoba, LC, Buxadera-Palomero, J, Marquina, A, Jiménez-Piqué, E, Ginebra, MP, Cortina, JL, Pegueroles, M, (2021). Zn-Mg and Zn-Cu alloys for stenting applications: From nanoscale mechanical characterization to in vitro degradation and biocompatibility Bioactive Materials 6, 4430-4446
In the recent decades, zinc (Zn) and its alloys have been drawing attention as promising candidates for bioresorbable cardiovascular stents due to its degradation rate more suitable than magnesium (Mg) and iron (Fe) alloys. However, its mechanical properties need to be improved in order to meet the criteria for vascular stents. This work investigates the mechanical properties, biodegradability and biocompatibility of Zn-Mg and Zn-Cu alloys in order to determine a proper alloy composition for optimal stent performance. Nanoindentation measurements are performed to characterize the mechanical properties at the nanoscale as a function of the Zn microstructure variations induced by alloying. The biodegradation mechanisms are discussed and correlated to microstructure, mechanical performance and bacterial/cell response. Addition of Mg or Cu alloying elements refined the microstructure of Zn and enhanced yield strength (YS) and ultimate tensile strength (UTS) proportional to the volume fraction of secondary phases. Zn-1Mg showed the higher YS and UTS and better performance in terms of degradation stability in Hanks’ solution. Zn-Cu alloys presented an antibacterial effect for S. aureus controlled by diffusion mechanisms and by contact. Biocompatibility was dependent on the degradation rate and the nature of the corrosion products.
JTD Keywords: behavior, biocompatibility, biodegradable metals, bioresorbable metals, bioresorbable scaffold, copper, corrosion properties, elastic-modulus, galvanic corrosion, microstructure, nanoindentation, redox homeostasis, zinc, Biocompatibility, Bioresorbable metals, Galvanic corrosion, Nanoindentation, Room-temperature superplasticity, Zinc alloys
Moreira, VB, Puiggalí-Jou, A, Jiménez-Piqué, E, Alemán, C, Meneguzzi, A, Armelin, E, (2021). Green nanocoatings based on the deposition of zirconium oxide: The role of the substrate Materials 14, 1043
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. Herein, the influence of the substrate in the formation of zirconium oxide monolayer, from an aqueous hexafluorozirconic acid solution, by chemical conversion and by electro-assisted deposi-tion, has been approached. The nanoscale dimensions of the ZrO2 film is affected by the substrate nature and roughness. This study evidenced that the mechanism of Zr-EAD is dependent on the potential applied and on the substrate composition, whereas conversion coating is uniquely dependent on the adsorption reaction time. The zirconium oxide based nanofilms were more homogenous in AA2024 substrates if compared to pure Al grade (AA1100). It was justified by the high content of Cu alloying element present in the grain boundaries of the latter. Such intermetallic active sites favor the obtaining of ZrO2 films, as demonstrated by XPS and AFM results. From a mechanistic point of view, the electrochemical reactions take place simultaneously with the conventional chemical conversion process driven by ions diffusion. Such findings will bring new perspectives for the generation of controlled oxide coatings in modified electrodes used, as for example, in the construction of battery cells; in automotive and in aerospace industries, to replace micrometric layers of zinc phosphate by light-weight zirconium oxide nanometric ones. This study is particularly addressed for the reduction of industrial waste by applying green bath solutions without the need of auxiliary compounds and using lightweight ceramic materials.
JTD Keywords: aluminum alloys, conversion coating, electro-assisted deposition, metal-oxide interface, nanocoating, zirconium oxide, Aluminum alloys, Conversion coating, Electro-assisted deposition, Metal-oxide interface, Nanocoating, Zirconium oxide