Gul, Merve, Fontana-Escartin, Adrian, Arnau, Marc, Sans, Jordi, Lanzalaco, Sonia, Armelin, Elaine, Chiesa, Enrica, Genta, Ida, Perez-Madrigal, Maria M, Aleman, Carlos, (2024). From Dielectric to Electro-Responsive Thermoplastics: An Approach Based on Electro-Thermal Reorientation and Charged Gas Activation Acs Applied Polymer Materials 6, 15070-15081

The transition from insulator to electro-responsive has been successfully achieved by earlier studies for some inorganic materials by applying external stimuli that modify their 3D and/or electronic structures. In the case of insulating polymers, this transition is frequently accomplished by mixing them with other electroactive materials, even though a few physical treatments that induce suitable chemical modifications have also been reported. In this work, a smart approach based on the application of an electro-thermal reorientation process followed by a charged gas activation treatment has been developed for transforming insulating 3D printed polymers into electro-responsive materials. First, the developed procedure has been exhaustively investigated for 3D printed poly(lactic acid) (PLA) and subsequently has been extended to 3D printed polypropylene (PP) and poly(ethylene terephthalate glycol) (PETG) specimens. FTIR and Raman spectroscopies, X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurements confirmed that, while the electro-thermal reorientation mainly promotes the crystallinity of the samples, the charged gas activation oxidizes the C-O bonds at the surface and consequently modifies the surface morphology and wettability. Furthermore, cyclic voltammetry assays demonstrated that treated PLA, PP, and PETG are electro-responsive, even though the electrochemical activity was much higher for oxygen-containing polymers (PLA and PETG) than for the oxygen-free one (PP). Finally, as a proof of concept, treated 3D printed PLA specimens have been used as electrochemical sensors to detect dopamine (DA), an important neurotransmitter, in a concentration interval ranging from 50 to 1000 mu M. The peak associated with the oxidation from DA to dopaminoquinone and the linearity of the calibration plot, which was constructed using the anodic peak current, proved that treated PLA is not only electro-responsive but also able to electrocatalyze the oxidation of DA.

JTD Keywords: 3d printin, Blends, Dopamine, Electrochemical detection, Electrochemical sensors, Electroresponsive polymers, Films, Hydrogels, Pl, Plasma treatment, Release, Thermoelectric treatment, Thermoplastic polymers


Mingot, J, Benejam, N, Víllora, G, Alemán, C, Armelin, E, Lanzalaco, S, (2023). Multimodal Biomedical Implant with Plasmonic and Simulated Body Temperature Responses Macromolecular Bioscience 23, e2300118

This work presents a novel nanoparticle-based thermosensor implant able to reveal the precise temperature variations along the polymer filaments, as it contracts and expands due to changes in the macroscale local temperature. The multimodal device is able to trace the position and the temperature of a polypropylene mesh, employed in abdominal hernia repair, by combining plasmon resonance and Raman spectroscopy with hydrogel responsive system. The novelty relies on the attachment of the biocompatible nanoparticles, based on gold stabilized by a chitosan-shell, already charged with the Raman reporter (RaR) molecules, to the robust prosthesis, without the need of chemical linkers. The SERS enhanced effect observed is potentiated by the presence of a quite thick layer of the copolymer (poly(N-isopropylacrylamide)-co-poly(acrylamide)) hydrogel. At temperatures above the LCST of PNIPAAm-co-PAAm, the water molecules are expulsed and the hydrogel layer contracts, leaving the RaR molecules more accessible to the Raman source. In vitro studies with fibroblast cells reveal that the functionalized surgical mesh is biocompatible and no toxic substances are leached in the medium. The mesh sensor opens new frontiers to semi-invasive diagnosis and infection prevention in hernia repair by using SERS spectroscopy. It also offers new possibilities to the functionalization of other healthcare products.© 2023 Wiley-VCH GmbH.

JTD Keywords: adhesion, blends, chitosan, gold nanoparticles, poly(n-isopropylacrylamide), polypropylene mesh, polypropylene meshes, repair, scattering, silver, surgical implants, thermosensitive hydrogels, toxicity, Chitosan, Gold nanoparticles, Polypropylene meshes, Surgical implants, Thermosensitive hydrogels


Fontana-Escartín, A, Lanzalaco, S, Pérez-Madrigal, MM, Bertran, O, Alemán, C, (2022). Electrochemical activation for sensing of three‐dimensional‐printed poly(lactic acid) using low‐pressure plasma Plasma Processes And Polymers 19, e2200101

Yazici, N, Opar, E, Kodal, M, Tanören, B, Sezen, M, Özkoc, G, (2022). A novel practical approach for monitoring the crosslink density of an ethylene propylene diene monomer compound: Complementary scanning acoustic microscopy and FIB-SEM-EDS analyses Polymers & Polymer Composites 30, 9673911221074192

Tuning of the crosslink density (CLD) in the rubber compounds is very crucial for optimizing the physical and mechanical properties of the ultimate rubber products. Conventionally, CLD can be measured via rheological methods such as moving die rheometer (MDR), via mechanical tests such as temperature scanning stress relaxation analysis (TSSR), or via direct swelling experiments using Flory–Rehner approach. In the current study, two novel techniques, focused ion beam - scanning electron microscopy (FIB-SEM) processing, with simultaneous energy dispersive X-ray spectrometry (EDS) mapping analysis and scanning acoustic microscopy (SAM) were combined and correlated to conventional methods on a model recipe of ethylene propylene diene monomer (EPDM) compound having different sulphur contents. Depending on the applied technique, the increase in the crosslink density with sulphur content was found to be 1.7 fold for the Flory–Rehner approach and 1.2 fold for both TSSR and MDR. It is directly monitored from the FIB-SEM-EDS analysis that the sulphur distribution and agglomeration behavior increased in line with ZnO content, which is an indirect indication of the rise in crosslink density. The impedance maps of the crosslinked samples obtained through SAM analysis revealed that the impedance of the samples increased with the increasing sulphur content, which can be attributed to higher level of crosslink density. A quantified correlation was obtained between SAM images and the crosslink density of the samples. It was shown that SAM is a promising tool for practical and non-destructive analysis for determining the formation of crosslink density of the rubbers. © The Author(s) 2022.

JTD Keywords: blends, compressibility, crosslink density, cure characteristics, ethylene propylene diene monomer, focused ion beam, mechanical-properties, morphology, natural-rubber, particles, scanning acoustic microscopy, scanning electron microscopy, sulfur, thermal-stability, vulcanization, Composite soft materials, Cross-link densities, Crosslink density, Crosslinking, Density (specific gravity), Ethylene, Ethylene propylene diene monomer, Flory-rehner, Focused ion beam - scanning electron microscopy, Focused ion beam-scanning electron microscopies, Ii-vi semiconductors, Monomers, Moving die rheometers, Physical and mechanical properties, Propylene, Relaxation analysis, Rubber, Scanning acoustic microscopy, Scanning electron microscopy, Stress relaxation, Sulfur contents, Temperature scanning stress relaxations, Zinc oxide


Serra, T., Navarro, M., Planell, J. A., (2012). Fabrication and characterization of biodegradable composite scaffolds for tissue engineering Innovative Developments in Virtual and Physical Prototyping 5th International Conference on Advanced Research and Rapid Prototyping (ed. Margarida, T., Ferreira, D.), Taylor & Francis (Leiria, Portugal) VR@P, 67-72

In this study, polylactic acid (PLA) and polyethylene glycol (PEG) were combined with soluble CaP glass particles and processed by rapid prototyping to obtain fully biodegradable structures for Tissue Engineering applications. The obtained 3D biodegradable structures were characterized in terms of their architecture and mechanical properties. The scaffold morphology, internal micro-architecture and mechanical properties were evaluated using Scanning Electron Microscopy (SEM), micro-computed tomography (micro-CT) and mechanical testing, respectively. Well defined structures with pore size of 350-400μm (in the axial view), struts width of approximately 70-80μm, and a porosity ranging between 60-65% were obtained. The combination RP and PLA/PEG/CaP glass turned into promising fully degradable, mechanically stable, bioactive and biocompatible composite scaffolds for TE.

JTD Keywords: Axial view, Biodegradable composites, Composite scaffolds, Glass particles, Mechanically stable, Micro architectures, Micro computed tomography (micro-CT), Poly lactic acid, Scaffold morphology, Tissue engineering applications, Well-defined structures, Bioactive glass, Mechanical properties, Mechanical testing, Polyethylene glycols, Polymer blends, Rapid prototyping, Scaffolds (biology), Scanning electron microscopy, Computerized tomography