DONATE

Publications

by Keyword: Gas ensor arrays

Fernandez, L., Gutierrez-Galvez, A., Marco, S., (2014). Robustness to sensor damage of a highly redundant gas sensor array Procedia Engineering 28th European Conference on Solid-State Transducers (EUROSENSORS 2014) , Eurosensors (Brescia, Italy) 87, 851-854

Abstract In this paper we study the role of redundant sensory information to prevent the performance degradation of a chemical sensor array as the number of faulty sensors increases. The large amount of sensing conditions with two different types of redundancy provided by our sensor array makes possible a comprehensive experimental study. Particularly, our sensor array is composed of 8 different types of commercial MOX sensors modulated in temperature with two redundancy levels: 1) 12 replicates of each sensor type for a total of 96 sensors, and 2) measurements using 16 load resistors per sensors for a total of 1536 redundant measures per second. The system is trained to identify ethanol, acetone and butanone using a PCA-LDA model. Test set samples are corrupted by means of three different simulated types of faults. To evaluate the tolerance of the array against sensor failure, the Fisher Score is used as a figure of merit for the corrupted test set samples projected on the PCA-LDA model.

JTD Keywords: Gas ensor arrays, sensor redundancy, MOX sensors, large sensor arrays.