DONATE

Publications

by Keyword: Magnetic-resonance

Madrid-Gambin, F, Oller, S, Marco, S, Pozo, OJ, Andres-Lacueva, C, Llorach, R, (2023). Quantitative plasma profiling by 1H NMR-based metabolomics: impact of sample treatment Frontiers In Molecular Biosciences 10, 1125582

Introduction: There is evidence that sample treatment of blood-based biosamples may affect integral signals in nuclear magnetic resonance-based metabolomics. The presence of macromolecules in plasma/serum samples makes investigating low-molecular-weight metabolites challenging. It is particularly relevant in the targeted approach, in which absolute concentrations of selected metabolites are often quantified based on the area of integral signals. Since there are a few treatments of plasma/serum samples for quantitative analysis without a universally accepted method, this topic remains of interest for future research. Methods: In this work, targeted metabolomic profiling of 43 metabolites was performed on pooled plasma to compare four methodologies consisting of Carr-Purcell-Meiboom-Gill (CPMG) editing, ultrafiltration, protein precipitation with methanol, and glycerophospholipid solid-phase extraction (g-SPE) for phospholipid removal; prior to NMR metabolomics analysis. The effect of the sample treatments on the metabolite concentrations was evaluated using a permutation test of multiclass and pairwise Fisher scores. Results: Results showed that methanol precipitation and ultrafiltration had a higher number of metabolites with coefficient of variation (CV) values above 20%. G-SPE and CPMG editing demonstrated better precision for most of the metabolites analyzed. However, differential quantification performance between procedures were metabolite-dependent. For example, pairwise comparisons showed that methanol precipitation and CPMG editing were suitable for quantifying citrate, while g-SPE showed better results for 2-hydroxybutyrate and tryptophan. Discussion: There are alterations in the absolute concentration of various metabolites that are dependent on the procedure. Considering these alterations is essential before proceeding with the quantification of treatment-sensitive metabolites in biological samples for improving biomarker discovery and biological interpretations. The study demonstrated that g-SPE and CPMG editing are effective methods for removing proteins and phospholipids from plasma samples for quantitative NMR analysis of metabolites. However, careful consideration should be given to the specific metabolites of interest and their susceptibility to the sample treatment procedures. These findings contribute to the development of optimized sample preparation protocols for metabolomics studies using NMR spectroscopy.Copyright © 2023 Madrid-Gambin, Oller, Marco, Pozo, Andres-Lacueva and Llorach.

JTD Keywords: binding, h-1-nmr spectroscopy, human serum, lactate, metabolites, nuclear magnetic resonance, plasma, protein, quantification, quantitative analysis, sample treatment, Metabolomics, Nuclear magnetic resonance, Nuclear-magnetic-resonance, Plasma, Quantification, Quantitative analysis, Sample treatment


Oerther, C, Marco-Rius, I, (2023). Chapter 14: Fast Multi-dimensional NMR for In Vivo Spectroscopy New Developments In Nmr 27, 415-440

Eills, J, Budker, D, Cavagnero, S, Chekmenev, EY, Elliott, SJ, Jannin, S, Lesage, A, Matysik, J, Meersmann, T, Prisner, T, Reimer, JA, Yang, HM, Koptyug, IV, (2023). Spin Hyperpolarization in Modern Magnetic Resonance Chemical Reviews 123, 1417-1551

Magnetic resonance techniques are successfully utilized in a broad range of scientific disciplines and in various practical applications, with medical magnetic resonance imaging being the most widely known example. Currently, both fundamental and applied magnetic resonance are enjoying a major boost owing to the rapidly developing field of spin hyperpolarization. Hyperpolarization techniques are able to enhance signal intensities in magnetic resonance by several orders of magnitude, and thus to largely overcome its major disadvantage of relatively low sensitivity. This provides new impetus for existing applications of magnetic resonance and opens the gates to exciting new possibilities. In this review, we provide a unified picture of the many methods and techniques that fall under the umbrella term "hyperpolarization" but are currently seldom perceived as integral parts of the same field. Specifically, before delving into the individual techniques, we provide a detailed analysis of the underlying principles of spin hyperpolarization. We attempt to uncover and classify the origins of hyperpolarization, to establish its sources and the specific mechanisms that enable the flow of polarization from a source to the target spins. We then give a more detailed analysis of individual hyperpolarization techniques: the mechanisms by which they work, fundamental and technical requirements, characteristic applications, unresolved issues, and possible future directions. We are seeing a continuous growth of activity in the field of spin hyperpolarization, and we expect the field to flourish as new and improved hyperpolarization techniques are implemented. Some key areas for development are in prolonging polarization lifetimes, making hyperpolarization techniques more generally applicable to chemical/biological systems, reducing the technical and equipment requirements, and creating more efficient excitation and detection schemes. We hope this review will facilitate the sharing of knowledge between subfields within the broad topic of hyperpolarization, to help overcome existing challenges in magnetic resonance and enable novel applications.

JTD Keywords: electron-paramagnetic-resonance, high-resolution nmr, hydrogen-induced polarization, level anti-crossings, long-lived states, parahydrogen-induced polarization, photosynthetic reaction-center, reversible exchange catalysis, solid-state nmr, Dynamic-nuclear-polarization


Kostas Mouloudakis, Sven Bodenstedt, Marc Azagra, Morgan W. Mitchell, Irene Marco-Rius, and Michael C. D. Tayler, (2023). Real-Time Polarimetry of Hyperpolarized 13C Nuclear Spins Using an Atomic Magnetometer Journal Of Physical Chemistry Letters 14, 1192-1197

We introduce a method for nondestructive quantification of nuclear spin polarization, of relevance to hyperpolarized spin tracers widely used in magnetic resonance from spectroscopy to in vivo imaging. In a bias field of around 30 nT we use a high-sensitivity miniaturized 87Rb-vapor magnetometer to measure the field generated by the sample, as it is driven by a windowed dynamical decoupling pulse sequence that both maximizes the nuclear spin lifetime and modulates the polarization for easy detection. We demonstrate the procedure applied to a 0.08 M hyperpolarized [1-13C]-pyruvate solution produced by dissolution dynamic nuclear polarization, measuring polarization repeatedly during natural decay at Earth's field. Application to real-time and continuous quality monitoring of hyperpolarized substances is discussed.

JTD Keywords: performance, polarization, Atomic magnetometers, Bias field, High sensitivity, Hyperpolarized, In-vivo imaging, Magnetic resonance, Magnetic-resonance, Magnetic-resonance,polarizatio, Magnetic-resonance,polarization,performanc, Magnetometers, Non destructive, Nuclear spins, Nuclear-spin polarization, Performance, Polarization, Rb vapors, Real- time, Spin dynamics, Spin polarization