DONATE

Publications

by Keyword: Typing

Badiola-Mateos, Maider, Di Giuseppe, Davide, Paoli, Roberto, Lopez-Martinez, Maria Jose, Mencattini, Arianna, Samitier, Josep, Martinelli, Eugenio, (2021). A novel multi-frequency trans-endothelial electrical resistance (MTEER) sensor array to monitor blood-brain barrier integrity Sensors And Actuators B-Chemical 334, 129599

© 2021 Elsevier B.V. The blood-brain barrier (BBB) is a dynamic cellular barrier that regulates brain nutrient supply, waste efflux, and paracellular diffusion through specialized junctional complexes. Finding a system to mimic and monitor BBB integrity (i.e., to be able to assess the effect of certain compounds on opening or closing the barrier) is of vital importance in several pathologies. This work aims to overcome some limitations of current barrier integrity measuring techniques thanks to a multi-layer microfluidic platform with integrated electrodes and Multi-frequency Trans-Endothelial Electrical Resistance (MTEER) in synergy with machine learning algorithms. MTEER measurements are performed across the barrier in a range of frequencies up to 10 MHz highlighting the presence of information on different frequency ranges. Results show that the proposed platform can detect barrier formation, opening, and regeneration afterwards, correlating with the results obtained from immunostaining of junctional complexes. This model presents novel techniques for a future biological barrier in-vitro studies that could potentially help on elucidating barrier opening or sealing on treatments with different drugs.

JTD Keywords: blood-brain barrier, cellular barrier integrity monitoring, impedance sensors, machine learning, microelectrodes, mteer, rapid prototyping, Blood-brain barrier, Cellular barrier integrity monitoring, Electrical impedance spectroscopy, Impedance sensors, Machine learning, Microelectrodes, Mteer, Rapid prototyping


Paoli, R, Badiola-Mateos, M, Lopez-Martinez, MJ, Samitier, J, Di Giuseppe, D, Martinelli, E, (2021). Rapid manufacturing of multilayered microfluidic devices for organ on a chip applications Sensors 21, 1382

© 2021 by the authors. Licensee MDPI, Basel, Switzerland. Microfabrication and Polydimethylsiloxane (PDMS) soft-lithography techniques became popular for microfluidic prototyping at the lab, but even after protocol optimization, fabrication is yet a long, laborious process and partly user-dependent. Furthermore, the time and money required for the master fabrication process, necessary at any design upgrade, is still elevated. Digital Manufacturing (DM) and Rapid-Prototyping (RP) for microfluidics applications arise as a solution to this and other limitations of photo and soft-lithography fabrication techniques. Particularly for this paper, we will focus on the use of subtractive DM techniques for Organ-on-a-Chip (OoC) applications. Main available thermoplastics for microfluidics are suggested as material choices for device fabrication. The aim of this review is to explore DM and RP technologies for fabrication of an OoC with an embedded membrane after the evaluation of the main limitations of PDMS soft-lithography strategy. Different material options are also reviewed, as well as various bonding strategies. Finally, a new functional OoC device is showed, defining protocols for its fabrication in Cyclic Olefin Polymer (COP) using two different RP technologies. Different cells are seeded in both sides of the membrane as a proof of concept to test the optical and fluidic properties of the device.

JTD Keywords: digital manufacturing, microfluidics, organ on a chip, rapid prototyping, Digital manufacturing, Microfluidics, Organ on a chip, Rapid prototyping


López-Carral, Héctor, Santos-Pata, D., Zucca, R., Verschure, P., (2019). How you type is what you type: Keystroke dynamics correlate with affective content ACII 2019 8th International Conference on Affective Computing and Intelligent Interaction , IEEE (Cabride, UK) , 1-5

Estimating the affective state of a user during a computer task traditionally relies on either subjective reports or analysis of physiological signals, facial expressions, and other measures. These methods have known limitations, can be intrusive and may require specialized equipment. An alternative would be employing a ubiquitous device of everyday use such as a standard keyboard. Here we investigate if we can infer the emotional state of a user by analyzing their typing patterns. To test this hypothesis, we asked 400 participants to caption a set of emotionally charged images taken from a standard database with known ratings of arousal and valence. We computed different keystroke pattern dynamics, including keystroke duration (dwell time) and latency (flight time). By computing the mean value of all of these features for each image, we found a statistically significant negative correlation between dwell times and valence, and between flight times and arousal. These results highlight the potential of using keystroke dynamics to estimate the affective state of a user in a non-obtrusive way and without the need for specialized devices.

JTD Keywords: Feature extraction, Correlation, Keyboards, Task analysis, Statistical analysis, Affective computing, Standards, Keystroke, Keyboard, Typing, Arousal, Valence, Affect


Serra, T., Ortiz-Hernandez, M., Engel, E., Planell, J. A., Navarro, M., (2014). Relevance of PEG in PLA-based blends for tissue engineering 3D-printed scaffolds Materials Science and Engineering: C 38, (1), 55-62

Achieving high quality 3D-printed structures requires establishing the right printing conditions. Finding processing conditions that satisfy both the fabrication process and the final required scaffold properties is crucial. This work stresses the importance of studying the outcome of the plasticizing effect of PEG on PLA-based blends used for the fabrication of 3D-direct-printed scaffolds for tissue engineering applications. For this, PLA/PEG blends with 5, 10 and 20% (w/w) of PEG and PLA/PEG/bioactive CaP glass composites were processed in the form of 3D rapid prototyping scaffolds. Surface analysis and differential scanning calorimetry revealed a rearrangement of polymer chains and a topography, wettability and elastic modulus increase of the studied surfaces as PEG was incorporated. Moreover, addition of 10 and 20% PEG led to non-uniform 3D structures with lower mechanical properties. In vitro degradation studies showed that the inclusion of PEG significantly accelerated the degradation rate of the material. Results indicated that the presence of PEG not only improves PLA processing but also leads to relevant surface, geometrical and structural changes including modulation of the degradation rate of PLA-based 3D printed scaffolds.

JTD Keywords: 3D-printing, Polylactic acid, Rapid prototyping, Scaffold, Surface characterization


Serra, T., Planell, J. A., Navarro, M., (2013). High-resolution PLA-based composite scaffolds via 3-D printing technology Acta Biomaterialia 9, (3), 5521-5530

Fabrication of new biodegradable scaffolds that guide and stimulate tissue regeneration is still a major issue in tissue engineering approaches. Scaffolds that possess adequate biodegradability, pore size, interconnectivity, bioactivity and mechanical properties in accordance with the injured tissue are required. This work aimed to develop and characterize three-dimensional (3-D) scaffolds that fulfill the aforementioned requirements. For this, a nozzle-based rapid prototyping system was used to combine polylactic acid and a bioactive CaP glass to fabricate 3-D biodegradable scaffolds with two patterns (orthogonal and displaced double layer). Scanning electron microscopy and micro-computer tomography showed that 3-D scaffolds had completely interconnected porosity, uniform distribution of the glass particles, and a controlled and repetitive architecture. Surface properties were also assessed, showing that the incorporation of glass particles increased both the roughness and the hydrophilicity of the scaffolds. Mechanical tests indicated that compression strength is dependent on the scaffold geometry and the presence of glass. Preliminary cell response was studied with primary mesenchymal stem cells (MSC) and revealed that CaP glass improved cell adhesion. Overall, the results showed the suitability of the technique/materials combination to develop 3-D porous scaffolds and their initial biocompatibility, both being valuable characteristics for tissue engineering applications.

JTD Keywords: Rapid prototyping, Scaffold, Polylactic acid, Biodegradable, Composite


Serra, T., Navarro, M., Planell, J. A., (2012). Fabrication and characterization of biodegradable composite scaffolds for tissue engineering Innovative Developments in Virtual and Physical Prototyping 5th International Conference on Advanced Research and Rapid Prototyping (ed. Margarida, T., Ferreira, D.), Taylor & Francis (Leiria, Portugal) VR@P, 67-72

In this study, polylactic acid (PLA) and polyethylene glycol (PEG) were combined with soluble CaP glass particles and processed by rapid prototyping to obtain fully biodegradable structures for Tissue Engineering applications. The obtained 3D biodegradable structures were characterized in terms of their architecture and mechanical properties. The scaffold morphology, internal micro-architecture and mechanical properties were evaluated using Scanning Electron Microscopy (SEM), micro-computed tomography (micro-CT) and mechanical testing, respectively. Well defined structures with pore size of 350-400μm (in the axial view), struts width of approximately 70-80μm, and a porosity ranging between 60-65% were obtained. The combination RP and PLA/PEG/CaP glass turned into promising fully degradable, mechanically stable, bioactive and biocompatible composite scaffolds for TE.

JTD Keywords: Axial view, Biodegradable composites, Composite scaffolds, Glass particles, Mechanically stable, Micro architectures, Micro computed tomography (micro-CT), Poly lactic acid, Scaffold morphology, Tissue engineering applications, Well-defined structures, Bioactive glass, Mechanical properties, Mechanical testing, Polyethylene glycols, Polymer blends, Rapid prototyping, Scaffolds (biology), Scanning electron microscopy, Computerized tomography


Olivares, A. L., Marshal, E., Planell, J. A., Lacroix, D., (2009). Finite element study of scaffold architecture design and culture conditions for tissue engineering Biomaterials 30, (30), 6142-6149

Tissue engineering scaffolds provide temporary mechanical support for tissue regeneration and transfer global mechanical load to mechanical stimuli to cells through its architecture. In this study the interactions between scaffold pore morphology, mechanical stimuli developed at the cell microscopic level, and culture conditions applied at the macroscopic scale are studied on two regular scaffold structures. Gyroid and hexagonal scaffolds of 55% and 70% porosity were modeled in a finite element analysis and were submitted to an inlet fluid flow or compressive strain. A mechanoregulation theory based on scaffold shear strain and fluid shear stress was applied for determining the influence of each structures on the mechanical stimuli on initial conditions. Results indicate that the distribution of shear stress induced by fluid perfusion is very dependent on pore distribution within the scaffold. Gyroid architectures provide a better accessibility of the fluid than hexagonal structures. Based on the mechanoregulation theory, the differentiation process in these structures was more sensitive to inlet fluid flow than axial strain of the scaffold. This study provides a computational approach to determine the mechanical stimuli at the cellular level when cells are cultured in a bioreactor and to relate mechanical stimuli with cell differentiation.

JTD Keywords: Tissue engineering, Scaffold, Rapid prototyping, Computational fluid dynamics, Finite element