DONATE

Publications

by Keyword: dls

Boda, SK, Willkomm, N, Barrera, MS, Mansky, L, Aparicio, C, (2023). Electrostatic capture of viruses on cationic biopolymer membranes for intra-oral disease sampling Colloids And Surfaces B-Biointerfaces 232, 113602

Naso- and oropharyngeal swabs are the Center for Disease Control and Prevention (CDC) -recommended disease sampling methods for respiratory viruses. The short swabbing time for sampling by these methods may lead to variability in test results. Further, these methods are mildly invasive and can cause discomfort, tearing or gag reflexes in tested individuals. If longer sampling time is coupled with lesser patient discomfort, test reliability and patient compliance can be improved. Towards this end, we developed cationic biopolymer membranes for the electrostatic capturing of viruses in the oral cavity. Here, chemically (EDC-NHS) crosslinked uncharged chitosan (CS) nanofiber membranes were conferred either with negative surface charge by anionic poly-aspartic acid (pAsp) coating or positive charge by cationic poly-L-lysine (PLL). Consistent with our preliminary findings of dynamic light scattering (DLS) size measurements showing large agglomerates of anionic virus-like particles (VLPs) and cationic PLL in solution, a 75% increase in VLP adsorption by PLL coated CS membranes was recorded by enzyme linked immunosorbent assay (ELISA), in comparison to untreated controls. It is envisaged that the electrostatic concentration of respiratory viruses on cationic membranes can be superior alternatives to traditional swabbing in the oral cavity.

JTD Keywords: Cationic biopolymer membranes, Disease sampling, Dynamic light scattering (dls), Electrostatic capture of viruses, Enzyme linked immunosorbent assay (elisa), Magnetic beads, Virus -like particles (vlps)


Tonelli, M, Catto, M, Sabaté, R, Francesconi, V, Laurini, E, Pricl, S, Pisani, L, Miniero, DV, Liuzzi, GM, Gatta, E, Relini, A, Gavín, R, Del Rio, JA, Sparatore, F, Carotti, A, (2023). Thioxanthenone-based derivatives as multitarget therapeutic leads for Alzheimer's disease European Journal Of Medicinal Chemistry 250, 115169

A set of twenty-five thioxanthene-9-one and xanthene-9-one derivatives, that were previously shown to inhibit cholinesterases (ChEs) and amyloid β (Aβ40) aggregation, were evaluated for the inhibition of tau protein aggregation. All compounds exhibited a good activity, and eight of them (5-8, 10, 14, 15 and 20) shared comparable low micromolar inhibitory potency versus Aβ40 aggregation and human acetylcholinesterase (AChE), while inhibiting human butyrylcholinesterase (BChE) even at submicromolar concentration. Compound 20 showed outstanding biological data, inhibiting tau protein and Aβ40 aggregation with IC50 = 1.8 and 1.3 μM, respectively. Moreover, at 0.1-10 μM it also exhibited neuroprotective activity against tau toxicity induced by okadoic acid in human neuroblastoma SH-SY5Y cells, that was comparable to that of estradiol and PD38. In preliminary toxicity studies, these interesting results for compound 20 are somewhat conflicting with a narrow safety window. However, compound 10, although endowed with a little lower potency for tau and Aβ aggregation inhibition additionally demonstrated good inhibition of ChEs and rather low cytotoxicity. Compound 4 is also worth of note for its high potency as hBChE inhibitor (IC50 = 7 nM) and for the three order of magnitude selectivity versus hAChE. Molecular modelling studies were performed to explain the different behavior of compounds 4 and 20 towards hBChE. The observed balance of the inhibitory potencies versus the relevant targets indicates the thioxanthene-9-one derivatives as potential MTDLs for AD therapy, provided that the safety window will be improved by further structural variations, currently under investigation.Copyright © 2023 Elsevier Masson SAS. All rights reserved.

JTD Keywords: a? and tau aggregation inhibition, ache and bche inhibition, aggregation, alzheimer?s disease, butyrylcholinesterase, design, drugs, dual inhibitors, fibrillization, multitarget-directed ligands (mtdls), peptide, polyphenols, potent, rivatives, Ache and bche inhibition, Alzheimer's disease, Amyloid-beta, Aβ and tau aggregation inhibition, Multitarget-directed ligands (mtdls), Thioxanthene-9-one and xanthen-9-one de, Thioxanthene-9-one and xanthen-9-one derivatives


Valles, M, Pujals, S, Albertazzi, L, Sánchez, S, (2022). Enzyme Purification Improves the Enzyme Loading, Self-Propulsion, and Endurance Performance of Micromotors Acs Nano 16, 5615-5626

Enzyme-powered micro- and nanomotors make use of biocatalysis to self-propel in aqueous media and hold immense promise for active and targeted drug delivery. Most (if not all) of these micro- and nanomotors described to date are fabricated using a commercially available enzyme, despite claims that some commercial preparations may not have a sufficiently high degree of purity for downstream applications. In this study, the purity of a commercial urease, an enzyme frequently used to power the motion of micro- and nanomotors, was evaluated and found to be impure. After separating the hexameric urease from the protein impurities by size-exclusion chromatography, the hexameric urease was subsequently characterized and used to functionalize hollow silica microcapsules. Micromotors loaded with purified urease were found to be 2.5 times more motile than the same micromotors loaded with unpurified urease, reaching average speeds of 5.5 ?m/s. After comparing a number of parameters, such as enzyme distribution, protein loading, and motor reusability, between micromotors functionalized with purified vs unpurified urease, it was concluded that protein purification was essential for optimal performance of the enzyme-powered micromotor.

JTD Keywords: canavalin, catalysis, delivery, dls, enhanced diffusion, enzyme, lipase immobilization, micromotors, self-propulsion, super-resolution microscopy, urease, Mesoporous silica nanoparticles, Micromotors, Super-resolution microscopy


Costa, JD, Ballester, BR, Verschure, PFMJ, (2021). A Rehabilitation Wearable Device to Overcome Post-stroke Learned Non-use. Methodology, Design and Usability Communications In Computer And Information Science 1538, 198-205

After a stroke, a great number of patients experience persistent motor impairments such as hemiparesis or weakness in one entire side of the body. As a result, the lack of use of the paretic limb might be one of the main contributors to functional loss after clinical discharge. We aim to reverse this cycle by promoting the use of the paretic limb during activities of daily living (ADLs). To do so, we describe the key components of a system composed of a wearable bracelet (i.e., a smartwatch) and a mobile phone, designed to bring a set of neurorehabilitation principles that promote acquisition, retention and generalization of skills to the home of the patient. A fundamental question is whether the loss in motor function derived from learned–non–use may emerge as a consequence of decision–making processes for motor optimization. Our system is based on well-established rehabilitation strategies that aim to reverse this behaviour by increasing the reward associated with action execution and implicitly reducing the expected cost of using the paretic limb, following the notion of reinforcement–induced movement therapy (RIMT). Here we validate an accelerometer-based measure of arm use and its capacity to discriminate different activities that require increasing movement of the arm. The usability and acceptance of the device as a rehabilitation tool is tested using a battery of self–reported and objective measurements obtained from acute/subacute patients and healthy controls. We believe that an extension of these technologies will allow for the deployment of unsupervised rehabilitation paradigms during and beyond hospitalization time. © 2021, Springer Nature Switzerland AG.

JTD Keywords: adls, hemiparesis, learned non-use, wearables, Activities of daily living, Adls, Functional loss, Generalisation, Hemiparesis, Learned non-use, Motor impairments, Neurorehabilitation [], Patient experiences, Stroke, Wearable devices, Wearable technology, Wearables