Andrian, T, Pujals, S, Albertazzi, L, (2021). Quantifying the effect of PEG architecture on nanoparticle ligand availability using DNA-PAINT Nanoscale Advances 3, 6876-6881

The importance of PEG architecture on nanoparticle (NP) functionality is known but still difficult to investigate, especially at a single particle level. Here, we apply DNA Point Accumulation for Imaging in Nanoscale Topography (DNA-PAINT), a super-resolution microscopy (SRM) technique, to study the surface functionality in poly(lactide-co-glycolide)-poly(ethylene glycol) (PLGA-PEG) NPs with different PEG structures. We demonstrated how the length of the PEG spacer can influence the accessibility of surface chemical functionality, highlighting the importance of SRM techniques to support the rational design of functionalized NPs.

JTD Keywords: chain-length, density, plga, surface, systems, Chain-length, Density, Dna, Microscopy technique, Nanoparticles, Nanoscale topography, Paint, Peg spacers, Plga, Poly lactide-co-glycolide, Poly-lactide-co-glycolide, Polyethylene glycols, Polylactide-co-glycolide, Single-particle, Super-resolution microscopy, Superresolution microscopy, Surface, Surface chemicals, Surface functionalities, Systems


Redondo-Morata, L., Giannotti, M. I., Sanz, F., (2012). AFM-based force-clamp monitors lipid bilayer failure kinetics Langmuir 28, (15), 6403-6410

The lipid bilayer rupture phenomenon is here explored by means of atomic force microscopy (AFM)-based force clamp, for the first time to our knowledge, to evaluate how lipid membranes respond when compressed under an external constant force, in the range of nanonewtons. Using this method, we were able to directly quantify the kinetics of the membrane rupture event and the associated energy barriers, for both single supported bilayers and multibilayers, in contradistinction to the classic studies performed at constant velocity. Moreover, the affected area of the membrane during the rupture process was calculated using an elastic deformation model. The elucidated information not only contributes to a better understanding of such relevant process, but also proves the suitability of AFM-based force clamp to study model structures as lipid bilayers. These findings on the kinetics of lipid bilayers rupture could be extended and applied to the study of other molecular thin films. Furthermore, systems of higher complexity such as models mimicking cell membranes could be studied by means of AFM-based force-clamp technique.

JTD Keywords: Chain-Length, Spectroscopy, Nanomechanics, Microscopy, Elasticity, Stability, Membranes, Reveals, Fusion, Ions


Garcia-Manyes, S., Redondo-Morata, L., Oncins, G., Sanz, F., (2010). Nanomechanics of lipid bilayers: Heads or tails? Journal of the American Chemical Society American Chemical Society 132, (37), 12874-12886

Understanding the effect of mechanical stress on membranes is of primary importance in biophysics. Here we use force spectroscopy AFM to quantitatively characterize the nanomechanical stability of supported lipid bilayers as a function of their chemical composition. The onset of plastic deformation reveals itself as a repetitive jump in the approaching force curve, which represents a molecular fingerprint for the bilayer mechanical stability. By systematically probing a set of chemically distinct supported lipid bilayers (SLBs), we first show that both the headgroup and tail have a decisive effect on their mechanical properties. While the mechanical stability of the probed SLBs linearly increases by 3.3 nN upon the introduction of each additional -CH2- in the chain, it exhibits a significant dependence on the phospholipid headgroup, ranging from 3 nN for DPPA to 66 nN for DPPG. Furthermore, we also quantify the reduction of the membrane mechanical stability as a function of the number of unsaturations and molecular branching in the chemical structure of the apolar tails. Finally, we demonstrate that, upon introduction of cholesterol and ergosterol, contrary to previous belief the mechanical stability of membranes not only increases linearly in the liquid phase (DLPC) but also for phospholipids present in the gel phase (DPPC). Our results are discussed in the framework of the continuum nucleation model. This work highlights the compelling effect of subtle variations in the chemical structure of phospholipid molecules on the membrane response when exposed to mechanical forces, a mechanism of common occurrence in nature.

JTD Keywords: Atomic-force microscopy, Molecular-dynamics simulation, Aqueous-electrolyte solutions, Supported planar membranes, Phospholipid-bilayers, Biological-membranes, Physical-properties, Fluid membranes, Model membranes, Chain-length


Oncins, G., Torrent-Burgues, J., Sanz, F., (2008). Nanomechanical properties of arachidic acid Langmuir-Blodgett films Journal of Physical Chemistry C 112, (6), 1967-1974

The nanomechanical properties of Langmuir-Blodgett monolayers of arachidic acid extracted at surface pressures of 1, 15, and 35 mN/m and deposited on mica were investigated by atomic force microscopy, force spectroscopy, and lateral force microscopy. It was experimentally demonstrated that the arachidic acid molecular orientation depends on the extraction pressure. According to this, tilting angles of 50, 34, and 22 degrees with respect to the surface perpendicular were detected and identified as conformations that maximize van der Waals interactions between the arachidic acid alkyl chains. The vertical force needed to puncture the monolayers with the AFM tip strongly depends on the molecular tilting angles attained at different monolayer extraction surface pressures, obtaining values that range from 13.07 +/- 3.24 nN for 50 degrees to 22.94 +/- 5.49 nN for 22 degrees tilting angles. The different molecular interactions involved in the monolayer cohesion are discussed and quantitatively related to the experimental monolayer breakthrough forces. The friction measurements performed from low vertical forces up to monolayer disruption reveal the existence of three well-defined regimes: first, a low friction response due to the elastic deformation of the monolayer, which is followed by a sharp increase in the friction force due to the onset of a sudden plastic deformation. The last regime corresponds to the monolayer rupture and the contact between tip and substrate. The friction coefficient of the substrate is seen to depend on the monolayer extraction pressure, a fact that is discussed in terms of the relationship between the sample compactness and its rupture mechanism.

JTD Keywords: AFM, SAM, Reflection-absortion spectroscopy, Lipid-bilayers, Frictional-properies, Molecular-structure, Thermal behavior, Nanometer-scale, Chain-length, LB films