by Keyword: Diaphragm electromyography

Rafols-de-Urquia, M., Estrada, L., Estevez-Piorno, J., Sarlabous, L., Jane, R., Torres, A., (2019). Evaluation of a wearable device to determine cardiorespiratory parameters from surface diaphragm electromyography IEEE Journal of Biomedical and Health Informatics 23, (5), 1964-1971

The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters from surface diaphragm electromyography (EMGdi). Twenty healthy volunteers underwent an incremental load respiratory test whilst EMGdi was recorded with a Shimmer3 wearable device (EMGdiW). Simultaneously, a second EMGdi (EMGdiL), inspiratory mouth pressure (Pmouth) and lead-I electrocardiogram (ECG) were recorded via a standard wired laboratory acquisition system. Different cardiorespiratory parameters were extracted from both EMGdiW and EMGdiL signals: heart rate, respiratory rate, respiratory muscle activity and mean frequency of EMGdi signals. Alongside these, similar parameters were also extracted from reference signals (Pmouth and ECG). High correlations were found between the data extracted from the EMGdiW and the reference signal data: heart rate (R = 0.947), respiratory rate (R = 0.940), respiratory muscle activity (R = 0.877), and mean frequency (R = 0.895). Moreover, similar increments in EMGdiW and EMGdiL activity were observed when Pmouth was raised, enabling the study of respiratory muscle activation. In summary, the Shimmer3 device is a promising and cost-effective solution for the ambulatory monitoring of respiratory muscle function in chronic respiratory diseases.

JTD Keywords: Cardiorespiratory monitoring, Chronic respiratory diseases, Fixed sample entropy, Non-invasive respiratory monitoring, Surface diaphragm electromyography, Wearable wireless device


Lozano-García, M., Estrada-Petrocelli, L., Moxham, J., Rafferty, G. F., Torres, A., Jolley, C. J., Jané, R. , (2019). Noninvasive assessment of inspiratory muscle neuromechanical coupling during inspiratory threshold loading IEEE Access 7, 183634-183646

Diaphragm neuromechanical coupling (NMC), which reflects the efficiency of conversion of neural activation to transdiaphragmatic pressure (Pdi), is increasingly recognized to be a useful clinical index of diaphragm function and respiratory mechanics in neuromuscular weakness and cardiorespiratory disease. However, the current gold standard assessment of diaphragm NMC requires invasive measurements of Pdi and crural diaphragm electromyography (oesEMGdi), which complicates the measurement of diaphragm NMC in clinical practice. This is the first study to compare invasive measurements of diaphragm NMC (iNMC) using the relationship between Pdi and oesEMGdi, with noninvasive assessment of NMC (nNMC) using surface mechanomyography (sMMGlic) and electromyography (sEMGlic) of lower chest wall inspiratory muscles. Both invasive and noninvasive measurements were recorded in twelve healthy adult subjects during an inspiratory threshold loading protocol. A linear relationship between noninvasive sMMGlic and sEMGlic measurements was found, resulting in little change in nNMC with increasing inspiratory load. By contrast, a curvilinear relationship between invasive Pdi and oesEMGdi measurements was observed, such that there was a progressive increase in iNMC with increasing inspiratory threshold load. Progressive recruitment of lower ribcage muscles, serving to enhance the mechanical advantage of the diaphragm, may explain the more linear relationship between sMMGlic and sEMGlic (both representing lower intercostal plus costal diaphragm activity) than between Pdi and crural oesEMGdi. Noninvasive indices of NMC derived from sEMGlic and sMMGlic may prove to be useful indices of lower chest wall inspiratory muscle NMC, particularly in settings that do not have access to invasive measures of diaphragm function.

JTD Keywords: Cardiovascular system, Diaphragms, Diseases, Electromyography, Medical signal processing, Neurophysiology, Patient monitoring, Pneumodynamics, Inspiratory muscle neuromechanical coupling, Diaphragm neuromechanical coupling, Neural activation, Transdiaphragmatic pressure, Diaphragm function, Respiratory mechanics, Diaphragm NMC, Invasive measurements, Crural diaphragm electromyography, iNMC, Noninvasive assessment, nNMC, Lower chest wall inspiratory muscles, Inspiratory threshold loading protocol, Noninvasive sMMGlic measurements, sEMGlic measurements, oesEMGdi measurements, Inspiratory threshold load, Lower ribcage muscles, Lower intercostal plus costal diaphragm activity, Crural oesEMGdi, Noninvasive indices, sEMGlic sMMGlic, Lower chest wall inspiratory muscle NMC, Surface mechanomyography, Electromyography, Inspiratory threshold loading, Mechanomyography, Neuromechanical coupling, Respiratory muscles


Sarlabous, L., Estrada, L., Cerezo-Hernández, A., Leest, Sietske V. D., Torres, A., Jané, R., Duiverman, M., Garde, Ainara, (2019). Electromyography-based respiratory onset detection in COPD patients on non-invasive mechanical ventilation Entropy 21, (3), 258

To optimize long-term nocturnal non-invasive ventilation in patients with chronic obstructive pulmonary disease, surface diaphragm electromyography (EMGdi) might be helpful to detect patient-ventilator asynchrony. However, visual analysis is labor-intensive and EMGdi is heavily corrupted by electrocardiographic (ECG) activity. Therefore, we developed an automatic method to detect inspiratory onset from EMGdi envelope using fixed sample entropy (fSE) and a dynamic threshold based on kernel density estimation (KDE). Moreover, we combined fSE with adaptive filtering techniques to reduce ECG interference and improve onset detection. The performance of EMGdi envelopes extracted by applying fSE and fSE with adaptive filtering was compared to the root mean square (RMS)-based envelope provided by the EMG acquisition device. Automatic onset detection accuracy, using these three envelopes, was evaluated through the root mean square error (RMSE) between the automatic and mean visual onsets (made by two observers). The fSE-based method provided lower RMSE, which was reduced from 298 ms to 264 ms when combined with adaptive filtering, compared to 301 ms provided by the RMS-based method. The RMSE was negatively correlated with the proposed EMGdi quality indices. Following further validation, fSE with KDE, combined with adaptive filtering when dealing with low quality EMGdi, indicates promise for detecting the neural onset of respiratory drive.

JTD Keywords: Fixed sample entropy, Adaptive filtering, Root mean square, Diaphragm electromyography, Non-invasive mechanical ventilation, Chronic obstructive pulmonary disease


Estrada, L., Torres, A., Sarlabous, L., Jané, R., (2017). Influence of parameter selection in fixed sample entropy of surface diaphragm electromyography for estimating respiratory activity Entropy 19, (9), 460

Fixed sample entropy (fSampEn) is a robust technique that allows the evaluation of inspiratory effort in diaphragm electromyography (EMGdi) signals, and has potential utility in sleep studies. To appropriately estimate respiratory effort, fSampEn requires the adjustment of several parameters. The aims of the present study were to evaluate the influence of the embedding dimension m, the tolerance value r, the size of the moving window, and the sampling frequency, and to establish recommendations for estimating the respiratory activity when using the fSampEn on surface EMGdi recorded for different inspiratory efforts. Values of m equal to 1 and r ranging from 0.1 to 0.64, and m equal to 2 and r ranging from 0.13 to 0.45, were found to be suitable for evaluating respiratory activity. fSampEn was less affected by window size than classical amplitude parameters. Finally, variations in sampling frequency could influence fSampEn results. In conclusion, the findings suggest the potential utility of fSampEn for estimating muscle respiratory effort in further sleep studies.

JTD Keywords: Fixed sample entropy (fSampEn), Non-invasive respiratory monitoring, Respiratory activity, Respiratory effort, Surface diaphragm electromyography