by Keyword: vibration
Olmo, C, Franco, L, Vidal, A, del Valle, LJ, Puiggalí, J, (2021). Ultrasound micromolding of porous polylactide/hydroxyapatite scaffolds Express Polymer Letters 15, 389-403
© BME-PT. Ultrasound micromolding (USM) preparation of hybrid scaffolds based on polylactide (PLA) and hydroxyapatite (HAp) particles has been evaluated. PLA was stable under the applied ultrasound source since a minimum degradation was detected. Porous materials were achieved using polyethylene glycol (PEG) and NaCl salts to the initial PLA and the subsequent leaching of the micromolded specimens. To avoid cavitation and decomposition problems during micromolding, it was necessary to use HAp free of typical synthesis impurities like carbonate and nitrate compounds. Compact PLA/HAp pieces allowed a maximum HAp load of 60 wt%, while porous specimens could be obtained with a maximum load of 38 wt%. Physical characterization of new scaffolds was performed by X-ray diffraction, spectroscopic and calorimetric techniques, stress-strain tests and contact angle measurements. Results indicated that a degree of porosity of 35% and relatively good mechanical properties could be achieved (i.e., 580 MPa, 4%, and 15.6 MPa for the Young modulus, elongation at break, and tensile strength, respectively). Scaffolds showed the positive effect of HAp and porosity on cell proliferation; this latter was 40% higher than that detected for non-porous PLA specimens.
JTD Keywords: apatite, conformation, fabrication, hydroxyapatite, micropieces, polymers, porous scaffolds, proliferation, tissue, ultrasound micromolding, vibration, Composite scaffolds, Hydroxyapatite, Micropieces, Porous scaffolds, Processing technologies, Ultrasound micromolding
Sarlabous, L., Torres, A., Fiz, J. A., Morera, J., Jané, R., (2012). Evaluation and adaptive attenuation of the cardiac vibration interference in mechanomyographic signals Engineering in Medicine and Biology Society (EMBC) 34th Annual International Conference of the IEEE , IEEE (San Diego, USA) , 3400-3403
The study of the mechanomyographic signal of the diaphragm muscle (MMGdi) is a promising technique in order to evaluate the respiratory muscles effort. The relationship between amplitude and frequency parameters of this signal with the respiratory effort performed during respiration is of great interest for researchers and physicians due to its diagnostic potentials. However, MMGdi signals are frequently contaminated by a cardiac vibration or mechanocardiographic (MCG) signal. An adaptive noise cancellation (ANC) can be used to reduce the MCG interference in the recorded MMGdi activity. In this paper, it is evaluated the proposed ANC scheme by means of a synthetic MMGdi signal with a controlled MCG interference. The Pearson's correlation coefficient (PCC) between both root mean square (RMS) and mean frequency (fm) of the synthetic MMGdi signal are considerably reduced with the presence of cardiac vibration noise (from 0.95 to 0.87, and from 0.97 to 0.76, respectively). With the ANC algorithm proposed the effect of the MCG noise on the amplitude and frequency of MMG parameters is reduced considerably (PCC of 0.93 and 0.97 for the RMS and fm, respectively). The ANC method proposed in this work is an interesting technique to attenuate the cardiac interference in respiratory MMG signals. Further investigation should be carried out to evaluate the performance of the ANC algorithm in real MMGdi signals.
JTD Keywords: Adaptive filters, Frequency modulation, Interference, Muscles, Noise cancellation, Vibrations, Cardiology, Medical signal processing, Muscle, Signal denoising, ANC algorithm, MCG interference, Pearson correlation coefficient, Adaptive noise cancellation, Cardiac vibration interference, Cardiac vibration noise, Diaphragm muscle, Mechanocardiographic signal, Mechanomyographic signals, Respiratory muscles effort