del Moral Zamora B, Azpeitia JMÁ, Farrarons JC, Català PLM, Corbera AH, Juárez A, Samitier J, (2022). Towards Point-of-Use Dielectrophoretic Methods: A New Portable Multiphase Generator for Bacteria Concentration World Congress On Medical Physics And Biomedical Engineering: Radiation Oncology 41, 856-859

This manuscript presents portable and low cost electronic system for specific point-of-use dielectrophoresis applications. The system is composed of two main modules: a) a multiphase generator based on a Class E amplifier, which provides 4 sinusoidal signals (0°, 90°, 180°, 270°) at 1 MHz with variable output voltage up to 10 Vpp (Vm) and an output driving current of 1 A; and b) a dielectrophoresis-based microfluidic chip containing two interdigitated electrodes. The system has been validated by concentrating Escherichia Coli at 1 MHz while applying a continuous flow of 5 ?L/min. Device functionalities were verified under different conditions achieving a 83% trapping efficiency in the best case. © Springer International Publishing Switzerland 2014.

JTD Keywords: bacteria, emulsifier, enterobacter, exopolysaccharide, Bacteria, Bacteria concentrations, Biochemical engineering, Cell concentrator, Class e amplifier, Class-e amplifier, Device functionality, Dielectrophoresis, Electronic equipment, Electronics, Electrophoresis, Emulsifier, Enterobacter, Escherichia coli, Exopolysaccharide, Inter-digitated electrodes, Lab-on-a-chip (loc), Low cost, Low costs, Low-cost electronics, Medical computing, Monosaccharide, Portable device, Power amplifiers, Trapping efficiencies


de la Serna, E, Arias-Alpízar, K, Borgheti-Cardoso, LN, Sanchez-Cano, A, Sulleiro, E, Zarzuela, F, Bosch-Nicolau, P, Salvador, F, Molina, I, Ramírez, M, Fernàndez-Busquets, X, Sánchez-Montalvá, A, Baldrich, E, (2021). Detection of Plasmodium falciparum malaria in 1 h using a simplified enzyme-linked immunosorbent assay Analytica Chimica Acta 1152, 338254

© 2021 Elsevier B.V. Malaria is a parasitic disease caused by protists of the genus Plasmodium, which are transmitted to humans through the bite of infected female Anopheles mosquitoes. Analytical methodologies and efficient drugs exist for the early detection and treatment of malaria, and yet this disease continues infecting millions of people and claiming several hundred thousand lives each year. One of the reasons behind this failure to control the disease is that the standard method for malaria diagnosis, microscopy, is time-consuming and requires trained personnel. Alternatively, rapid diagnostic tests, which have become common for point-of-care testing thanks to their simplicity of use, tend to be insufficiently sensitive and reliable, and PCR, which is sensitive, is too complex and expensive for massive population screening. In this work, we report a sensitive simplified ELISA for the quantitation of Plasmodium falciparum lactate dehydrogenase (Pf-LDH), which is capable of detecting malaria in 45–60 min. Assay development was founded in the selection of high-performance antibodies, implementation of a poly-horseradish peroxidase (polyHRP) signal amplifier, and optimization of whole-blood sample pre-treatment. The simplified ELISA achieved limits of detection (LOD) and quantification (LOQ) of 0.11 ng mL−1 and 0.37 ng mL−1, respectively, in lysed whole blood, and an LOD comparable to that of PCR in Plasmodium in vitro cultures (0.67 and 1.33 parasites μL−1 for ELISA and PCR, respectively). Accordingly, the developed immunoassay represents a simple and effective diagnostic tool for P. falciparum malaria, with a time-to-result of <60 min and sensitivity similar to the reference PCR, but easier to implement in low-resource settings.

JTD Keywords: malaria quantitative diagnosis, plasmodium culture, plasmodium ldh, polyhrp signal amplifier, simplified elisa, Malaria quantitative diagnosis, Plasmodium culture, Plasmodium ldh, Polyhrp signal amplifier, Simplified elisa


Colomer-Farrarons, J., Miribel-Catala, P. L., Samitier, J., Arundell, M., Rodriguez, I., (2009). Design of a miniaturized electrochemical instrument for in-situ O/sub 2/ monitoring Sensors and Signal Conditioning VLSI Circuits and Systems IV , SPIE (Desdren, Germany) 7363, 73630A

The authors are working toward the design of a device for the detection of oxygen, following a discrete and an integrated instrumentation implementation. The discrete electronics are also used for preliminary analysis, to confirm the validity of the conception of system, and its set-up would be used in the characterization of the integrated device, waiting for the chip fabrication. This paper presents the design of a small and portable potentiostat integrated with electrodes, which is cheap and miniaturized, which can be applied for on-site measurements for the simultaneous detection of O/sub 2/ and temperature in water systems. As a first approach a discrete PCB has been designed based on commercial discrete electronics and specific oxygen sensors. Dissolved oxygen concentration (DO) is an important index of water quality and the ability to measure the oxygen concentration and temperature at different positions and depths would be an important attribute to environmental analysis. Especially, the objective is that the sensor and the electronics can be integrated in a single encapsulated device able to be submerged in environmental water systems and be able to make multiple measurements. For our proposed application a small and portable device is developed, where electronics and sensors are miniaturized and placed in close proximity to each other. This system would be based on the sensors and electronics, forming one module, and connected to a portable notebook to save and analyze the measurements on-line. The key electronics is defined by the potentiostat amplifier, used to fix the voltage between the working (WE) and reference (RE) electrodes following an input voltage (Vin). Vin is a triangular signal, programmed by a LabView/sup c / interface, which is also used to represent the CV transfers. To obtain a smaller and compact solution the potentiostat amplifier has also been integrated defining a full custom ASIC amplifier, which is in progress, looking for a point-of-care device. These circuits have been designed with a 0.13 mu m technology from ST Microelectronics through the CMP-TIMA service.

JTD Keywords: Amplifiers, Application specific integrated circuits, Chemical sensors, Electrodes, Portable instruments, Temperature measurement, Water sources