Teule-Trull, Miriam, Demiquels-Punzano, Elena, Perez, Roman A, Aparicio, Conrado, Duran-Sindreu, Fernando, Sanchez-Lopez, Elena, Gonzalez-Sanchez, Jose Antonio, Delgado, Luis M, (2024). Revision of ex vivo endodontic biofilm model using computer aided design Journal Of Dentistry 149, 105270
Objective: Most endodontic diseases are bacterium-mediated inflammatory or necrotic process induced by contaminated dental pulp. Although great advances are being performed to obtain more efficient antibacterial strategies for persistent infections, most studies lack of representative models to test their antibacterial effects and their outcomes cannot be promptly translated to clinical practice. Therefore, this study aimed to refine an ex vivo endodontic biofilm model combining human tooth, computer guided design and 3D printing to obtain a more reproducible and predictable model. Methods: Monoradicular teeth were cut using three different methods: hand-held (HCC), mechanical precision (MPC) and computer aid guided cutting (CGC). Then, blocks were reassembled. The different model preparations were assessed in terms of dimensional tolerance, surface analysis, liquid tightness and Enterococcus faecalis biofilm development for 21 days, which was studied by metabolic assays and confocal microscopy. Then, the proposed model was validated using different commercial disinfecting treatments. Results: CGC exhibited significantly lower deviation and surface without defects compared to HHC and MPC, leading to superior liquid tightness. Similarly, mature biofilms with high metabolic activity and vitality were observed in all conditions, CGC showing the lowest variation. Regarding the model validation, all antibacterial treatments resulted in the complete eradication of bacteria in the standard 2D model, whereas commercial treatments exhibited varying levels of efficacy in the proposed ex vivo model, from moderately reduction of metabolic activity to complete elimination of biofilm. Conclusions: The novel guided approach represents a more reliable, standardized, and reproducible model for the evaluation of endodontic disinfecting therapies. Clinical Significance: During antibacterial treatment development, challenging 3D models using teeth substrates to test antibacterial treatments novel guided approach represents a more reliable, standardized, and reproducible model for the evaluation of endodontic disinfecting therapies.
JTD Keywords: 3d printin, Bacteria, Biofilm, Computer-aided manufacturing, Dental model, Dentin, Efficacy, Endodontics, Enterococcus faecalis, Enterococcus-faecalis, Irrigation, Protocols, Removal, Resistance, Susceptibility, Syste
Lozano-Garcia, M, Estrada-Petrocelli, L, Blanco-Almazan, D, Tas, B, Cho, PSP, Moxham, J, Rafferty, GF, Torres, A, Jane, R, Jolley, CJ, (2022). Noninvasive Assessment of Neuromechanical and Neuroventilatory Coupling in COPD Ieee Journal Of Biomedical And Health Informatics 26, 3385-3396
This study explored the use of parasternal second intercostal space and lower intercostal space surface electromyogram (sEMG) and surface mechanomyogram (sMMG) recordings (sEMGpara and sMMGpara, and sEMGlic and sMMGlic, respectively) to assess neural respiratory drive (NRD), neuromechanical (NMC) and neuroventilatory (NVC) coupling, and mechanical efficiency (MEff) noninvasively in healthy subjects and chronic obstructive pulmonary disease (COPD) patients. sEMGpara, sMMGpara, sEMGlic, sMMGlic, mouth pressure (Pmo), and volume (Vi) were measured at rest, and during an inspiratory loading protocol, in 16 COPD patients (8 moderate and 8 severe) and 9 healthy subjects. Myographic signals were analyzed using fixed sample entropy and normalized to their largest values (fSEsEMGpara%max, fSEsMMGpara%max, fSEsEMGlic%max, and fSEsMMGlic%max). fSEsMMGpara%max, fSEsEMGpara%max, and fSEsEMGlic%max were significantly higher in COPD than in healthy participants at rest. Parasternal intercostal muscle NMC was significantly higher in healthy than in COPD participants at rest, but not during threshold loading. Pmo-derived NMC and MEff ratios were lower in severe patients than in mild patients or healthy subjects during threshold loading, but differences were not consistently significant. During resting breathing and threshold loading, Vi-derived NVC and MEff ratios were significantly lower in severe patients than in mild patients or healthy subjects. sMMG is a potential noninvasive alternative to sEMG for assessing NRD in COPD. The ratios of Pmo and Vi to sMMG and sEMG measurements provide wholly noninvasive NMC, NVC, and MEff indices that are sensitive to impaired respiratory mechanics in COPD and are therefore of potential value to assess disease severity in clinical practice. Author
JTD Keywords: biomedical measurement, chronic obstructive pulmonary disease, couplings, diaphragm, disease severity, efficiency, electromyography, exacerbations, healthy volunteers, inspiratory muscles, loading, mechanomyography, obstructive pulmonary-disease, pressure measurement, protocols, respiratory mechanics, respiratory muscles, responsiveness, spirometry, stimulation, volume measurement, At rests, Biomedical measurement, Biomedical measurements, Chronic obstructive pulmonary disease, Couplings, Disease severity, Efficiency ratio, Electromyography, Healthy subjects, Healthy volunteers, Loading, Mechanical efficiency, Mechanomyogram, Muscle, Muscles, Neural respiratory drive, Noninvasive medical procedures, Pressure measurement, Protocols, Pulmonary diseases, Surface electromyogram, Volume measurement
Romero, D, Jané, R, (2021). Global and Transient Effects of Intermittent Hypoxia on Heart Rate Variability Markers: Evaluation using an Obstructive Sleep Apnea Model Ieee Access 9, 19043-19052
CCBY Intermittent hypoxia (IH) produces autonomic dysfunction that promotes the development of arrhythmia and hypertension in patients with obstructive sleep apnea (OSA). This paper investigated different heart rate variability (HRV) indices in the context of IH using a rat model for OSA. Linear and non-linear HRV parameters were assessed from ultra-short (15-s segments) and short-term (5 min) analyses of heartbeat time-series. Transient changes observed from pre-apnea segments to hypoxia episodes were evaluated, besides the relative and global impact of IH, as a function of its severity. Results showed an overall increase in ultra-short HRV markers as immediate response to hypoxia: standard deviation of normal RR intervals, SDNN=1.2 ms (IQR: 1.1-2.1) vs 1.4 ms (IQR: 1.2-2.2), p=0.015; root mean square of the successive differences, RMSSD=1.7 ms (IQR: 1.5-2.2) vs 1.9 ms (IQR: 1.6-2.4), p=0.031. The power in the very low frequency (VLF) band also showed a significant increase: 0.09 ms2 (IQR: 0.05-0.20) vs 0.16 ms2 (IQR: 0.12-0.23), p=0.016, probably associated with the potentiation of the carotid body chemo-sensory response to hypoxia. Moreover, a clear link between severity of IH and short-term HRV measures was found in VLF and LF power, besides their progressive increase seen throughout the experiment after each apnea sequence. However, only those markers quantifying fragmentation levels in RR series were significantly affected when the experiment ended, as compared to baseline measures: percentage of inflection points, PIP=49% (IQR: 45-51) vs 53% (IQR: 47-53), p=0.031; percentage of short (≥3 RR intervals) accelerated/decelerated segments, PSS=75% (IQR: 51-81) vs 87% (IQR: 51-90), p=0.046. These findings suggest a significant deterioration of cardiac rhythm with a more erratic behavior beyond the normal sinus arrhythmia, that may lead to a future cardiac condition.
JTD Keywords: artificial intelligence, atmospheric modeling, electrocardiography, heart rate variability, hypoxia rat model, intermittent hypoxia, obstructive apneas, protocols, radio access technologies, Artificial intelligence, Atmospheric modeling, Electrocardiography, Heart rate variability, Hypoxia rat model, Intermittent hypoxia, Obstructive apneas, Protocols, Radio access technologies, Rats
Romero, D., Jané, R., (2020). Hypoxia-induced effects on ECG depolarization by time warping analysis during recurrent obstructive apnea Engineering in Medicine & Biology Society (EMBC) 42nd Annual International Conference of the IEEE , IEEE (Montreal, Canada) , 2626-2629
In this work, we evaluated a non-linear approach to estimate morphological variations in ECG depolarization, in the context of intermittent hypoxia (IH). Obstructive apnea sequences were provoked for 15 minutes in anesthetized Sprague-Dawley rats, alternating with equal periods of normal breathing, in a recurrent obstructive sleep apnea (OSA) model. Each apnea episode lasted 15 s, while the frequency used for each sequence was randomly selected. Average heartbeats obtained before the start and at the end of each episode, were delineated to extract only the QRS wave. Then, the segmented QRS waves were non-linearly aligned using the dynamic time warping (DWT) algorithm. Morphological QRS changes in both the amplitude and temporal domains were estimated from this alignment procedure. The hypoxic and basal segments were analyzed using ECG (lead I) recordings acquired during the experiment. To assess the effects of IH over time, the changes relative to the basal QRS wave were determined, in the intervals prior to each successive events until the end of the experiment. The results showed a progressive increase in the amplitude and time-domain morphological markers of the QRS wave along the experiment, which were strongly correlated with the changes in traditional QRS markers (r ≈ 0.9). Significant changes were found between pre-apnea and hypoxic measures only for the time-domain analysis (p<0.001), probably due to the short duration of the simulated apnea episodes.Clinical relevance Increased variability in ECG depolarization morphology during recurrent hypoxic episodes would be closely related to the expression of cardiovascular dysfunction in OSA patients.
JTD Keywords: Electrocardiography, Rats, Heart rate variability, Sleep apnea, Protocols, Heuristic algorithms
Blanco-Almazán, D., Groenendaal, W., Catthoor, F., Jané, R., (2019). Analysis of time delay between bioimpedance and respiratory volume signals under inspiratory loaded breathing Engineering in Medicine and Biology Society (EMBC) 41st Annual International Conference of the IEEE , IEEE (Berlín, Germany) , 2365-2368
Bioimpedance is known for its linear relation with volume during normal breathing. For that reason, bioimpedance can be used as a noninvasive and comfortable technique for measuring respiration. The goal of this study is to analyze the temporal behavior of bioimpedance measured in four different electrode configurations during inspiratory loaded breathing. We measured four bioimpedance channels and airflow simultaneously in 10 healthy subjects while incremental inspiratory loads were imposed. Inspiratory loading threshold protocols are associated with breathing pattern changes and were used in respiratory mechanics studies. Consequently, this respiratory protocol allowed us to induce breathing pattern changes and evaluate the temporal relationship of bioimpedance with volume. We estimated the temporal delay between bioimpedance and volume respiratory cycles to evaluate the differences in their temporal behavior. The delays were computed as the lag which maximize the cross-correlation of the signals cycle by cycle. Six of the ten subjects showed delays in at least two different inspiratory loads. The delays were dependent on electrode configuration, hence the appearance of the delays between bioimpedance and volume were conditioned to the location and geometry of the electrode configuration. In conclusion, the delays between these signals could provide information about breathing pattern when breathing conditions change.
JTD Keywords: Bioimpedance, Delays, Electrodes, Protocols, Loading, Electrocardiography, Atmospheric measurements
Estrada, L., Sarlabous, L., Lozano-García, M., Jané, R., Torres, A., (2019). Neural offset time evaluation in surface respiratory signals during controlled respiration Engineering in Medicine and Biology Society (EMBC) 41st Annual International Conference of the IEEE , IEEE (Berlín, Germany) , 2344-2347
The electrical activity of the diaphragm measured by surface electromyography (sEMGdi) provides indirect information on neural respiratory drive. Moreover, it allows evaluating the ventilatory pattern from the onset and offset (ntoff) estimation of the neural inspiratory time. sEMGdi amplitude variation was quantified using the fixed sample entropy (fSampEn), a less sensitive method to the interference from cardiac activity. The detection of the ntoff is controversial, since it is located in an intermediate point between the maximum value and the cessation of sEMGdi inspiratory activity, evaluated by the fSampEn. In this work ntoff detection has been analyzed using thresholds between 40% and 100 % of the fSampEn peak. Furthermore, fSampEn was evaluated analyzing the r parameter from 0.05 to 0.6, using a m equal to 1 and a sliding window size equal to 250 ms. The ntoff has been compared to the offset time (toff) obtained from the airflow during a controlled respiratory protocol varying the fractional inspiratory time from 0.54 to 0.18 whilst the respiratory rate was constant at 16 bpm. Results show that the optimal threshold values were between 66.0 % to 77.0 % of the fSampEn peak value. r values between 0.25 to 0.50 were found suitable to be used with the fSampEn.
JTD Keywords: Protocols, Low pass filters, Electrodes, Standards, Band-pass filters, Muscles, Cutoff frequency
Romero, D., Jané, R., (2019). Non-linear HRV analysis to quantify the effects of intermittent hypoxia using an OSA rat model Engineering in Medicine and Biology Society (EMBC) 41st Annual International Conference of the IEEE , IEEE (Berlín, Germany) , 4994-4997
In this paper, a non-linear HRV analysis was performed to assess fragmentation signatures observed in heartbeat time series after intermittent hypoxia (IH). Three markers quantifying short-term fragmentation levels, PIP, IALS and PSS, were evaluated on R-R interval series obtained in a rat model of recurrent apnea. Through airway obstructions, apnea episodes were periodically simulated in six anesthetized Sprague-Dawley rats. The number of apnea events per hour (AHI index) was varied during the first half of the experiment while apnea episodes lasted 15 s. For the second part, apnea episodes lasted 5, 10 or 15 s, but the AHI index was fixed. Recurrent apnea was repeated for 15-min time intervals in all cases, alternating with basal periods of the same duration. The fragmentation markers were evaluated in segments of 5 minutes, selected at the beginning and end of the experiment. The impact of the heart and breathing rates (HR and BR, respectively) on the parameter estimates was also investigated. The results obtained show a significant increase (from 5 to 10%, p <; 0.05) in fragmentation measures of heartbeat time series after IH, indicating a clear deterioration of the initial conditions. Moreover, there was a strong linear relationship (r > 0.9) between these markers and BR, as well as with the ratio given by HR/BR. Although fragmentation may be impacted by IH, we found that it is highly dependent on HR and BR values and thus, they should be considered during its calculation or used to normalize the fragmentation estimates.
JTD Keywords: Rats, Time series analysis, Radio access technologies, Protocols, Heart beat
Perea-Gil, I., Uriarte, J. J., Prat-Vidal, C., Gálvez-Montón, C., Roura, S., Llucià-Valldeperas, A., Soler-Botija, C., Farré, R., Navajas, D., Bayes-Genis, A., (2015). In vitro comparative study of two decellularization protocols in search of an optimal myocardial scaffold for recellularization American Journal of Translational Research , 7, (3), 558-573
Introduction. Selection of a biomaterial-based scaffold that mimics native myocardial extracellular matrix (ECM) architecture can facilitate functional cell attachment and differentiation. Although decellularized myocardial ECM accomplishes these premises, decellularization processes may variably distort or degrade ECM structure. Materials and methods. Two decellularization protocols (DP) were tested on porcine heart samples (epicardium, mid myocardium and endocardium). One protocol, DP1, was detergent-based (SDS and Triton X-100), followed by DNase I treatment. The other protocol, DP2, was focused in trypsin and acid with Triton X-100 treatments. Decellularized myocardial scaffolds were reseeded by embedding them in RAD16-I peptidic hydrogel with adipose tissue-derived progenitor cells (ATDPCs). Results. Both protocols yielded acellular myocardial scaffolds (~82% and ~94% DNA reduction for DP1 and DP2, respectively). Ultramicroscopic assessment of scaffolds was similar for both protocols and showed filamentous ECM with preserved fiber disposition and structure. DP1 resulted in more biodegradable scaffolds (P = 0.04). Atomic force microscopy revealed no substantial ECM stiffness changes post-decellularization compared to native tissue. The Young’s modulus did not differ between heart layers (P = 0.69) or decellularization protocols (P = 0.15). After one week, recellularized DP1 scaffolds contained higher cell density (236 ± 106 and 98 ± 56 cells/mm2 for recellularized DP1 and DP2 scaffolds, respectively; P = 0.04). ATDPCs in both DP1 and DP2 scaffolds expressed the endothelial marker isolectin B4, but only in the DP1 scaffold ATDPCs expressed the cardiac markers GATA4, connexin43 and cardiac troponin T. Conclusions. In our hands, DP1 produced myocardial scaffolds with higher cell repopulation and promotes ATDPCs expression of endothelial and cardiomyogenic markers.
JTD Keywords: Acellular myocardial scaffold, Adipose tissue-derived progenitor cells, Decellularization protocols, Extracellular matrix, Myocardial infarction, Recellularization
Estrada, L., Torres, A., Sarlabous, L., Jané, R., (2015). EMG-derived respiration signal using the fixed sample entropy during an Inspiratory load protocol Engineering in Medicine and Biology Society (EMBC) 37th Annual International Conference of the IEEE , IEEE (Milan, Italy) , 1703-1706
Extracting clinical information from one single measurement represents a step forward in the assessment of the respiratory muscle function. This attracting idea entails the reduction of the instrumentation and fosters to develop new medical integrated technologies. We present the use of the fixed sample entropy (fSampEn) as a more direct method to non-invasively derive the breathing activity from the diaphragm electromyographic (EMGdi) signal, and thus to extract the respiratory rate, an important vital sign which is cumbersome and time-consuming to be measured by clinicians. fSampEn is a method to evaluate the EMGdi activity that is less sensitive to the cardiac activity (ECG) and its application has proven to be useful to evaluate the load of the respiratory muscles. The behavior of the proposed method was tested in signals from two subjects that performed an inspiratory load protocol, which consists of increments in the inspiratory mouth pressure (Pmouth). Two respiratory signals were derived and compared to the Pmouth signal: the ECG-derived respiration (EDR) signal from the lead-I configuration, and the EMG-derived respiration (EMGDR) signal by applying the fSampEn method over the EMGdi signal. The similitude and the lag between signals were calculated through the cross-correlation between each derived respiratory signal and the Pmouth. The EMGDR signal showed higher correlation and lower lag values (≥ 0.91 and ≤ 0.70 s, respectively) than the EDR signal (≥ 0.83 and ≤0.99 s, respectively). Additionally, the respiratory rate was estimated with the Pmouth, EDR and EMGDR signals showing very similar values. The results from this preliminary work suggest that the fSampEn method can be used to derive the respiration waveform from the respiratory muscle electrical activity.
JTD Keywords: Band-pass filters, Electrocardiography, Electromyography, Entropy, Mouth, Muscles, Protocols
Estrada, L., Torres, A., Sarlabous, L., Jané, R., (2015). Respiratory signal derived from the smartphone built-in accelerometer during a Respiratory Load Protocol Engineering in Medicine and Biology Society (EMBC) 37th Annual International Conference of the IEEE , IEEE (Milan, Italy) , 6768-6771
The scope of our work focuses on investigating the potential use of the built-in accelerometer of the smartphones for the recording of the respiratory activity and deriving the respiratory rate. Five healthy subjects performed an inspiratory load protocol. The excursion of the right chest was recorded using the built-in triaxial accelerometer of a smartphone along the x, y and z axes and with an external uniaxial accelerometer. Simultaneously, the respiratory airflow and the inspiratory mouth pressure were recorded, as reference respiratory signals. The chest acceleration signal recorded in the z axis with the smartphone was denoised using a scheme based on the ensemble empirical mode decomposition, a noise data assisted method which decomposes nonstationary and nonlinear signals into intrinsic mode functions. To distinguish noisy oscillatory modes from the relevant modes we use the detrended fluctuation analysis. We reported a very strong correlation between the acceleration of the z axis of the smartphone and the reference accelerometer across the inspiratory load protocol (from 0.80 to 0.97). Furthermore, the evaluation of the respiratory rate showed a very strong correlation (0.98). A good agreement was observed between the respiratory rate estimated with the chest acceleration signal from the z axis of the smartphone and with the respiratory airflow signal: Bland-Altman limits of agreement between -1.44 and 1.46 breaths per minute with a mean bias of -0.01 breaths per minute. This preliminary study provides a valuable insight into the use of the smartphone and its built-in accelerometer for respiratory monitoring.
JTD Keywords: Acceleration, Accelerometers, Correlation, Empirical mode decomposition, Fluctuations, Protocols, Time series analysis
Estrada, Luis, Torres, Abel, Sarlabous, Leonardo, Fiz, Jose A., Gea, Joaquim, Martinez-Llorens, Juana, Jané, Raimon, (2014). Estimation of bilateral asynchrony between diaphragm mechanomyographic signals in patients with Chronic Obstructive Pulmonary Disease Engineering in Medicine and Biology Society (EMBC) 36th Annual International Conference of the IEEE , IEEE (Chicago, USA) , 3813-3816
The aim of the present study was to measure bilateral asynchrony in patients suffering from Chronic Obstructive Pulmonary Disease (COPD) performing an incremental inspiratory load protocol. Bilateral asynchrony was estimated by the comparison of respiratory movements derived from diaphragm mechanomyographic (MMGdi) signals, acquired by means of capacitive accelerometers placed on left and right sides of the rib cage. Three methods were considered for asynchrony evaluation: Lissajous figure, Hilbert transform and Motto's algorithm. Bilateral asynchrony showed an increase at 20, 40 and 60% (values of normalized inspiratory pressure by their maximum value reached in the last inspiratory load) while the very severe group showed and increase at 20, 40, 80, and 100 % during the protocol. These increments in the phase's shift can be due to an increase of the inspiratory load along the protocol, and also as a consequence of distress and fatigue. In summary, this work evidenced the capability to estimate bilateral asynchrony in COPD patients. These preliminary results also showed that the use of capacitive accelerometers can be a suitable sensor for recording of respiratory movement and evaluation of asynchrony in COPD patients.
JTD Keywords: Accelerometers, Diseases, Estimation, Fatigue, IP networks, Protocols, Transforms