DONATE

Publications

by Keyword: Chromatography

Freire, R, Mego, M, Oliveira, LF, Mas, S, Azpiroz, F, Marco, S, Pardo, A, (2022). Quantitative GC–TCD Measurements of Major Flatus Components: A Preliminary Analysis of the Diet Effect Sensors 22, 838

The impact of diet and digestive disorders in flatus composition remains largely unexplored. This is partially due to the lack of standardized sampling collection methods, and the easy atmospheric contamination. This paper describes a method to quantitatively determine the major gases in flatus and their application in a nutritional intervention. We describe how to direct sample flatus into Tedlar bags, and simultaneous analysis by gas chromatography–thermal conductivity detection (GC–TCD). Results are analyzed by univariate hypothesis testing and by multilevel principal component analysis. The reported methodology allows simultaneous determination of the five major gases with root mean measurement errors of 0.8% for oxygen (O2), 0.9% for nitrogen (N2), 0.14% for carbon dioxide (CO2), 0.11% for methane (CH4), and 0.26% for hydrogen (H2). The atmospheric contamination was limited to 0.86 (95% CI: [0.7–1.0])% for oxygen and 3.4 (95% CI: [1.4–5.3])% for nitrogen. As an illustration, the method has been successfully applied to measure the response to a nutritional intervention in a reduced crossover study in healthy subjects. © 2022 by the authors. Licensee MDPI, Basel, Switzerland.

JTD Keywords: breath, colonic microbiota, diet effect on flatus, disorders, evacuation, excretion, flatulence, hydrogen gas, major flatus gas components, multilevel principal component analysis, rectal gas collection, systems, volume, Atmospheric contamination, Carbon dioxide, Conductivity detection, Diet effect on flatus, Gas chromatography, Gas collections, Gas component, Gases, Major flatus gas component, Major flatus gas components, Multilevel principal component analyse, Multilevel principal component analysis, Multilevels, Nitrogen, Nutrition, Oxygen, Principal component analysis, Principal-component analysis, Rectal gas collection, Volatile organic-compounds


Guallar-Garrido, S, Almiñana-Rapún, F, Campo-Pérez, V, Torrents, E, Luquin, M, Julián, E, (2022). BCG Substrains Change Their Outermost Surface as a Function of Growth Media Vaccines 10, 40

Mycobacterium bovis bacillus Calmette-Guérin (BCG) efficacy as an immunotherapy tool can be influenced by the genetic background or immune status of the treated population and by the BCG substrain used. BCG comprises several substrains with genetic differences that elicit diverse phenotypic characteristics. Moreover, modifications of phenotypic characteristics can be influenced by culture conditions. However, several culture media formulations are used worldwide to produce BCG. To elucidate the influence of growth conditions on BCG characteristics, five different substrains were grown on two culture media, and the lipidic profile and physico-chemical properties were evaluated. Our results show that each BCG substrain displays a variety of lipidic profiles on the outermost surface depending on the growth conditions. These modifications lead to a breadth of hydrophobicity patterns and a different ability to reduce neutral red dye within the same BCG substrain, suggesting the influence of BCG growth conditions on the interaction between BCG cells and host cells.

JTD Keywords: cell wall, efficacy, glycerol, hydrophobicity, lipid, neutral red, pdim, pgl, protein, strains, viability, virulence, Acylglycerol, Albumin, Article, Asparagine, Bacterial cell wall, Bacterial gene, Bacterium culture, Bcg vaccine, Catalase, Cell wall, Chloroform, Controlled study, Escherichia coli, Gene expression, Genomic dna, Glycerol, Glycerol monomycolate, Hexadecane, Housekeeping gene, Hydrophobicity, Immune response, Immunogenicity, Immunotherapy, Lipid, Lipid fingerprinting, Magnesium sulfate, Mercaptoethanol, Methanol, Methylglyoxal, Molybdatophosphoric acid, Mycobacterium bovis bcg, Neutral red, Nonhuman, Pdim, Petroleum ether, Pgl, Phenotype, Physical chemistry, Real time reverse transcription polymerase chain reaction, Rna 16s, Rna extraction, Rv0577, Staining, Thin layer chromatography, Unclassified drug


Abramov, A, Maiti, B, Keridou, I, Puiggalí, J, Reiser, O, Díaz, DD, (2021). A pH-Triggered Polymer Degradation or Drug Delivery System by Light-Mediated Cis/Trans Isomerization of o-Hydroxy Cinnamates Macromolecular Rapid Communications 42, 2100213

A new methodology for the pH-triggered degradation of polymers or for the release of drugs under visible light irradiation based on the cyclization of ortho-hydroxy-cinnamates (oHC) to coumarins is described. The key oHC structural motif can be readily incorporated into the rational design of novel photocleavable polymers via click chemistry. This main-chain moiety undergoes a fast photocleavage when irradiated with 455 nm light provided that a suitable base is added. A series of polyethylene glycol-alt-ortho-hydroxy cinnamate (polyethylene glycol (PEG)(n)-alt-oHC)-based polymers are synthesized and the time-dependent visible-light initiated cleavage of the photoactive monomer and polymer is investigated in solution by a variety of spectroscopic and chromatographic techniques. The photo-degradation behavior of the water-soluble poly(PEG(2000)-alt-oHC) is investigated within a broad pH range (pH = 2.1-11.8), demonstrating fast degradation at pH 11.8, while the stability of the polymer is greatly enhanced at pH 2.1. Moreover, the neat polymer shows long-term stability under daylight conditions, thus allowing its storage without special precautions. In addition, two water-soluble PEG-based drug-carrier molecules (mPEG(2000)-oHC-benzhydrol/phenol) are synthesized and used for drug delivery studies, monitoring the process by UV-vis spectroscopy in an ON/OFF intermittent manner.

JTD Keywords: coumarins, drug delivery, e/z-double bond isomerization, o-hydroxy cinnamates, polymer degradation, Aliphatic compounds, Antioxidant activity, Antitumor, Chromatographic techniques, Chromatography, Cis/trans isomerization, Controlled drug delivery, Coumarin derivatives, Coumarins, Drug delivery, Drug delivery system, E/z-double bond isomerization, Films, Hydrogels, Image enhancement, Light, Long term stability, O-hydroxy cinnamates, Particles, Photoactive monomers, Photodegradation, Polyethylene glycols, Polyethylenes, Polymer degradation, Responsive polymers, Salts, Structural motifs, Synthesis (chemical), Targeted drug delivery, Visible light photocatalysis, Visible-light irradiation


Mallafré-Muro, C, Llambrich, M, Cumeras, R, Pardo, A, Brezmes, J, Marco, S, Gumà, J, (2021). Comprehensive volatilome and metabolome signatures of colorectal cancer in urine: A systematic review and meta‐analysis Cancers 13, 2534

To increase compliance with colorectal cancer screening programs and to reduce the recommended screening age, cheaper and easy non‐invasiveness alternatives to the fecal immunochemical test should be provided. Following the PRISMA procedure of studies that evaluated the metabolome and volatilome signatures of colorectal cancer in human urine samples, an exhaustive search in PubMed, Web of Science, and Scopus found 28 studies that met the required criteria. There were no restrictions on the query for the type of study, leading to not only colorectal cancer samples versus control comparison but also polyps versus control and prospective studies of surgical effects, CRC staging and comparisons of CRC with other cancers. With this systematic review, we identified up to 244 compounds in urine samples (3 shared compounds between the volatilome and metabolome), and 10 of them were relevant in more than three articles. In the meta-analysis, nine studies met the criteria for inclusion, and the results combining the case‐control and the pre‐/post‐surgery groups, eleven compounds were found to be relevant. Four upregulated metabolites were identified, 3‐hydroxybutyric acid, L‐dopa, L‐histidinol, and N1, N12‐ diacetylspermine and seven downregulated compounds were identified, pyruvic acid, hydroquinone, tartaric acid, and hippuric acid as metabolites and butyraldehyde, ether, and 1,1,6‐ trimethyl‐1,2‐dihydronaphthalene as volatiles.

JTD Keywords: biomarkers, breast, chromatography, colorectal cancer, diagnosis, markers, meta-analysis, metabolomics, metabonomics, n-1,n-12-diacetylspermine, nucleosides, systematic review, urine, validation, volatilomics, Colorectal cancer, Early-stage, Metabolomics, Meta‐analysis, Systematic review, Urine, Volatilomics


Taghadomi-Saberi, S., Garcia, S. M., Masoumi, A. A., Sadeghi, M., Marco, S., (2018). Classification of bitter orange essential oils according to fruit ripening stage by untargeted chemical profiling and machine learning Sensors 18, (6), 1922

The quality and composition of bitter orange essential oils (EOs) strongly depend on the ripening stage of the citrus fruit. The concentration of volatile compounds and consequently its organoleptic perception varies. While this can be detected by trained humans, we propose an objective approach for assessing the bitter orange from the volatile composition of their EO. The method is based on the combined use of headspace gas chromatography–mass spectrometry (HS-GC-MS) and artificial neural networks (ANN) for predictive modeling. Data obtained from the analysis of HS-GC-MS were preprocessed to select relevant peaks in the total ion chromatogram as input features for ANN. Results showed that key volatile compounds have enough predictive power to accurately classify the EO, according to their ripening stage for different applications. A sensitivity analysis detected the key compounds to identify the ripening stage. This study provides a novel strategy for the quality control of bitter orange EO without subjective methods.

JTD Keywords: Bitter orange essential oil, Headspace gas chromatography–mass spectrometry, Artificial neural network, Foodomics, Chemometrics, Feature selection


Moles, E., Marcos, J., Imperial, S., Pozo, O. J., Fernàndez-Busquets, X., (2017). 2-picolylamine derivatization for high sensitivity detection of abscisic acid in apicomplexan blood-infecting parasites Talanta 168, 130-135

We have developed a new liquid chromatography-electrospray ionization tandem mass spectrometry methodology based on 2-picolylamine derivatization and positive ion mode detection for abscisic acid (ABA) identification. The selected reaction leads to the formation of an amide derivative which contains a highly active pyridyl group. The enhanced ionization allows for a 700-fold increase over commonly monitored unmodified ABA, which in turn leads to excellent limits of detection and quantification values of 0.03 and 0.15 ng mL-1, respectively. This method has been validated in the highly complex matrix of a red blood cell extract. In spite of the high sensitivity achieved, ABA could not be detected in Plasmodium falciparum-infected red blood cells, suggesting that, if present, it will be found either in ultratrace amounts or as brief bursts at defined time points within the intraerythrocytic cycle and/or in the form of a biosynthetic analogue.

JTD Keywords: Abscisic acid, Apicomplexa, Liquid chromatography-electrospray ionization tandem mass spectrometry, Malaria, Picolylamine, Plasmodium falciparum


Oller-Moreno, S., Singla-Buxarrais, G., Jiménez-Soto, J. M., Pardo, Antonio, Garrido-Delgado, R., Arce, L., Marco, Santiago, (2015). Sliding window multi-curve resolution: Application to gas chromatography - Ion Mobility Spectrometry Sensors and Actuators B: Chemical 15th International Meeting on Chemical Sensors , Elsevier (Buenos Aires, Argentina) 217, 13-21

Abstract Blind Source Separation (BSS) techniques aim to extract a set of source signals from a measured mixture in an unsupervised manner. In the chemical instrumentation domain source signals typically refer to time-varying analyte concentrations, while the measured mixture is the set of observed spectra. Several techniques exist to perform BSS on Ion Mobility Spectrometry, being Simple-to-use interactive self-modeling mixture analysis (SIMPLISMA) and Multivariate Curve Resolution (MCR) the most commonly used. The addition of a multi-capillary gas chromatography column using the ion mobility spectrometer as detector has been proposed in the past to increase chemical resolution. Short chromatography times lead to high levels of co-elution, and ion mobility spectra are key to resolve them. For the first time, BSS techniques are used to deconvolve samples of the gas chromatography - ion mobility spectrometry tandem. We propose a method to extract spectra and concentration profiles based on the application of MCR in a sliding window. Our results provide clear concentration profiles and pure spectra, resolving peaks that were not detected by the conventional use of MCR. The proposed technique could also be applied to other hyphenated instruments with similar strong co-elutions.

JTD Keywords: Blind Source Separation, Multivariate Curve Resolution, Ion Mobility Spectrometry, Gas Chromatography, Hyphenated instrumentation, SIMPLISMA, co-elution


Oller-Moreno, S., Pardo, A., Jimenez-Soto, J. M., Samitier, J., Marco, S., (2014). Adaptive Asymmetric Least Squares baseline estimation for analytical instruments SSD 2014 Proceedings 11th International Multi-Conference on Systems, Signals & Devices (SSD) , IEEE (Castelldefels-Barcelona, Spain) , 1569846703

Automated signal processing in analytical instrumentation is today required for the analysis of highly complex biomedical samples. Baseline estimation techniques are often used to correct long term instrument contamination or degradation. They are essential for accurate peak area integration. Some methods approach the baseline estimation iteratively, trying to ignore peaks which do not belong to the baseline. The proposed method in this work consists of a modification of the Asymmetric Least Squares (ALS) baseline removal technique developed by Eilers and Boelens. The ALS technique suffers from bias in the presence of intense peaks (in relation to the noise level). This is typical of diverse instrumental techniques such as Gas Chromatography-Mass Spectrometry (GC-MS) or Gas Chromatography-Ion Mobility Spectrometry (GC-IMS). In this work, we propose a modification (named psalsa) to the asymmetry weights of the original ALS method in order to better reject large peaks above the baseline. Our method will be compared to several versions of the ALS algorithm using synthetic and real GC signals. Results show that our proposal improves previous versions being more robust to parameter variations and providing more accurate peak areas.

JTD Keywords: Gas chromatography, Instruments, Radioactivity measurement, Signal processing, Analytical instrument, Analytical Instrumentation, Asymmetric least squares, Baseline estimation, Baseline removal, Gas chromatography-mass spectrometries (GC-MS), Instrumental techniques, Noise levels, Iterative methods


Perera, A., Pardo, A., Barrettino, D., Hierlermann, A., Marco, S., (2009). Evaluation of fish spoilage by means of a single metal oxide sensor under temperature modulation Olfaction and Electronic Nose: Proceedings of the 13th International Symposium on Olfaction and Electronic Nose 13th International Symposium on Olfaction and Electronic Nose (ed. Pardo, M., Sberveglieri, G.), Amer Inst Physics (Brescia, Italy) 1137, 483-486

In this paper the feasibility of using metal oxide gas sensor technology for evaluating spoilage process for sea bream (Sparus Aurata) is explored. It is shown that a single sensor under temperature modulation is able to find a correlation with the fish spoilage process

JTD Keywords: Gas sensors, Electrochemical sensors, Chromatography