DONATE

Publications

by Keyword: Magnetic

Boda, SK, Willkomm, N, Barrera, MS, Mansky, L, Aparicio, C, (2023). Electrostatic capture of viruses on cationic biopolymer membranes for intra-oral disease sampling Colloids And Surfaces B-Biointerfaces 232, 113602

Naso- and oropharyngeal swabs are the Center for Disease Control and Prevention (CDC) -recommended disease sampling methods for respiratory viruses. The short swabbing time for sampling by these methods may lead to variability in test results. Further, these methods are mildly invasive and can cause discomfort, tearing or gag reflexes in tested individuals. If longer sampling time is coupled with lesser patient discomfort, test reliability and patient compliance can be improved. Towards this end, we developed cationic biopolymer membranes for the electrostatic capturing of viruses in the oral cavity. Here, chemically (EDC-NHS) crosslinked uncharged chitosan (CS) nanofiber membranes were conferred either with negative surface charge by anionic poly-aspartic acid (pAsp) coating or positive charge by cationic poly-L-lysine (PLL). Consistent with our preliminary findings of dynamic light scattering (DLS) size measurements showing large agglomerates of anionic virus-like particles (VLPs) and cationic PLL in solution, a 75% increase in VLP adsorption by PLL coated CS membranes was recorded by enzyme linked immunosorbent assay (ELISA), in comparison to untreated controls. It is envisaged that the electrostatic concentration of respiratory viruses on cationic membranes can be superior alternatives to traditional swabbing in the oral cavity.

JTD Keywords: Cationic biopolymer membranes, Disease sampling, Dynamic light scattering (dls), Electrostatic capture of viruses, Enzyme linked immunosorbent assay (elisa), Magnetic beads, Virus -like particles (vlps)


Gallo, J, Villasante, A, (2023). Recent Advances in Biomimetic Nanocarrier-Based Photothermal Therapy for Cancer Treatment International Journal Of Molecular Sciences 24, 15484

Nanomedicine presents innovative solutions for cancer treatment, including photothermal therapy (PTT). PTT centers on the design of photoactivatable nanoparticles capable of absorbing non-toxic near-infrared light, generating heat within target cells to induce cell death. The successful transition from benchside to bedside application of PTT critically depends on the core properties of nanoparticles responsible for converting light into heat and the surface properties for precise cell-specific targeting. Precisely targeting the intended cells remains a primary challenge in PTT. In recent years, a groundbreaking approach has emerged to address this challenge by functionalizing nanocarriers and enhancing cell targeting. This strategy involves the creation of biomimetic nanoparticles that combine desired biocompatibility properties with the immune evasion mechanisms of natural materials. This review comprehensively outlines various strategies for designing biomimetic photoactivatable nanocarriers for PTT, with a primary focus on its application in cancer therapy. Additionally, we shed light on the hurdles involved in translating PTT from research to clinical practice, along with an overview of current clinical applications.

JTD Keywords: biomimetic nanoparticles, cancer treatment, diagnosis, drug-delivery, erythrocyte-membrane, facile synthesis, iron-oxide nanoparticles, magnetic nanoparticles, membrane-camouflaged nanoparticles, metastatic breast-cancer, size, stem-cells, Biomimetic nanoparticles, Cancer treatment, Membrane-camouflaged nanoparticles, Photothermal therapy


Sauer, F, Grosser, S, Shahryari, M, Hayn, A, Guo, J, Braun, J, Briest, S, Wolf, B, Aktas, B, Horn, LC, Sack, I, Käs, JA, (2023). Changes in Tissue Fluidity Predict Tumor Aggressiveness In Vivo Advanced Science 10, e2303523

Cancer progression is caused by genetic changes and associated with various alterations in cell properties, which also affect a tumor's mechanical state. While an increased stiffness has been well known for long for solid tumors, it has limited prognostic power. It is hypothesized that cancer progression is accompanied by tissue fluidization, where portions of the tissue can change position across different length scales. Supported by tabletop magnetic resonance elastography (MRE) on stroma mimicking collagen gels and microscopic analysis of live cells inside patient derived tumor explants, an overview is provided of how cancer associated mechanisms, including cellular unjamming, proliferation, microenvironment composition, and remodeling can alter a tissue's fluidity and stiffness. In vivo, state-of-the-art multifrequency MRE can distinguish tumors from their surrounding host tissue by their rheological fingerprints. Most importantly, a meta-analysis on the currently available clinical studies is conducted and universal trends are identified. The results and conclusions are condensed into a gedankenexperiment about how a tumor can grow and eventually metastasize into its environment from a physics perspective to deduce corresponding mechanical properties. Based on stiffness, fluidity, spatial heterogeneity, and texture of the tumor front a roadmap for a prognosis of a tumor's aggressiveness and metastatic potential is presented.© 2023 The Authors. Advanced Science published by Wiley-VCH GmbH.

JTD Keywords: brain, cancer, cells, collective migration, elastic energy, elastography, in vivo magnetic resonance elastography, invasion, medical imaging, solid stress, tissue fluidity, tumor mechanics, viscoelastic properties, Cancer, Extracellular-matrix, In vivo magnetic resonance elastography, Medical imaging, Tissue fluidity, Tumor mechanics


Magdanz, V, Klingner, A, Abelmann, L, Khalil, ISM, (2023). IRONSperm swimming by rigid-body rotation versus transverse bending waves influenced by cell membrane charge Journal Of Micro-Bio Robotics 18, 49-60

Cell membrane potential affects the electrostatic self-assembly of magnetizable nanoparticles around the flagellum of sperm cells, leading to the formation of biohybrid microrobots (i.e., IRONSperm) with various bending stiffness. Here we explain the influence of bull sperm cell membrane potential on the formation of two types of IRONSperm samples that are produced by electrostatic self-assembly. The first type is a proximal-coated soft body with nanoparticles concentrated on the head to maintain high flexibility of the flagellum and create a passively propagating transverse bending wave under the influence of an external rotating magnetic field. The second type is a rigid-body with nanoparticles approximately uniformly distributed along the length to provide arbitrary geometry that maintains a constant chiral shape and propel by rotation about its long axis. We present a magneto-elastohydrodynamic model to predict the swimming speed at low Reynolds number for rigid IRONSperm with arbitrary shapes, and show that decreasing the bending stiffness allows the model to capture the behavior of its soft counterpart. While the response of a rigid chiral IRONSperm is distinguished by a greater swimming speed with a smooth decay with frequency, the benefit of a soft flagellum in certain scenarios would present a much smaller range of frequencies for wireless actuation.

JTD Keywords: Biohybrid, Magnetic, Microrobots, Nanoparticles, Propulsion, Sperm cells


Madrid-Gambin, F, Oller, S, Marco, S, Pozo, OJ, Andres-Lacueva, C, Llorach, R, (2023). Quantitative plasma profiling by 1H NMR-based metabolomics: impact of sample treatment Frontiers In Molecular Biosciences 10, 1125582

Introduction: There is evidence that sample treatment of blood-based biosamples may affect integral signals in nuclear magnetic resonance-based metabolomics. The presence of macromolecules in plasma/serum samples makes investigating low-molecular-weight metabolites challenging. It is particularly relevant in the targeted approach, in which absolute concentrations of selected metabolites are often quantified based on the area of integral signals. Since there are a few treatments of plasma/serum samples for quantitative analysis without a universally accepted method, this topic remains of interest for future research. Methods: In this work, targeted metabolomic profiling of 43 metabolites was performed on pooled plasma to compare four methodologies consisting of Carr-Purcell-Meiboom-Gill (CPMG) editing, ultrafiltration, protein precipitation with methanol, and glycerophospholipid solid-phase extraction (g-SPE) for phospholipid removal; prior to NMR metabolomics analysis. The effect of the sample treatments on the metabolite concentrations was evaluated using a permutation test of multiclass and pairwise Fisher scores. Results: Results showed that methanol precipitation and ultrafiltration had a higher number of metabolites with coefficient of variation (CV) values above 20%. G-SPE and CPMG editing demonstrated better precision for most of the metabolites analyzed. However, differential quantification performance between procedures were metabolite-dependent. For example, pairwise comparisons showed that methanol precipitation and CPMG editing were suitable for quantifying citrate, while g-SPE showed better results for 2-hydroxybutyrate and tryptophan. Discussion: There are alterations in the absolute concentration of various metabolites that are dependent on the procedure. Considering these alterations is essential before proceeding with the quantification of treatment-sensitive metabolites in biological samples for improving biomarker discovery and biological interpretations. The study demonstrated that g-SPE and CPMG editing are effective methods for removing proteins and phospholipids from plasma samples for quantitative NMR analysis of metabolites. However, careful consideration should be given to the specific metabolites of interest and their susceptibility to the sample treatment procedures. These findings contribute to the development of optimized sample preparation protocols for metabolomics studies using NMR spectroscopy.Copyright © 2023 Madrid-Gambin, Oller, Marco, Pozo, Andres-Lacueva and Llorach.

JTD Keywords: binding, h-1-nmr spectroscopy, human serum, lactate, metabolites, nuclear magnetic resonance, plasma, protein, quantification, quantitative analysis, sample treatment, Metabolomics, Nuclear magnetic resonance, Nuclear-magnetic-resonance, Plasma, Quantification, Quantitative analysis, Sample treatment


Eills, J, Budker, D, Cavagnero, S, Chekmenev, EY, Elliott, SJ, Jannin, S, Lesage, A, Matysik, J, Meersmann, T, Prisner, T, Reimer, JA, Yang, HM, Koptyug, IV, (2023). Spin Hyperpolarization in Modern Magnetic Resonance Chemical Reviews 123, 1417-1551

Magnetic resonance techniques are successfully utilized in a broad range of scientific disciplines and in various practical applications, with medical magnetic resonance imaging being the most widely known example. Currently, both fundamental and applied magnetic resonance are enjoying a major boost owing to the rapidly developing field of spin hyperpolarization. Hyperpolarization techniques are able to enhance signal intensities in magnetic resonance by several orders of magnitude, and thus to largely overcome its major disadvantage of relatively low sensitivity. This provides new impetus for existing applications of magnetic resonance and opens the gates to exciting new possibilities. In this review, we provide a unified picture of the many methods and techniques that fall under the umbrella term "hyperpolarization" but are currently seldom perceived as integral parts of the same field. Specifically, before delving into the individual techniques, we provide a detailed analysis of the underlying principles of spin hyperpolarization. We attempt to uncover and classify the origins of hyperpolarization, to establish its sources and the specific mechanisms that enable the flow of polarization from a source to the target spins. We then give a more detailed analysis of individual hyperpolarization techniques: the mechanisms by which they work, fundamental and technical requirements, characteristic applications, unresolved issues, and possible future directions. We are seeing a continuous growth of activity in the field of spin hyperpolarization, and we expect the field to flourish as new and improved hyperpolarization techniques are implemented. Some key areas for development are in prolonging polarization lifetimes, making hyperpolarization techniques more generally applicable to chemical/biological systems, reducing the technical and equipment requirements, and creating more efficient excitation and detection schemes. We hope this review will facilitate the sharing of knowledge between subfields within the broad topic of hyperpolarization, to help overcome existing challenges in magnetic resonance and enable novel applications.

JTD Keywords: electron-paramagnetic-resonance, high-resolution nmr, hydrogen-induced polarization, level anti-crossings, long-lived states, parahydrogen-induced polarization, photosynthetic reaction-center, reversible exchange catalysis, solid-state nmr, Dynamic-nuclear-polarization


Mouloudakis, K, Bodenstedt, S, Azagra, M, Mitchell, MW, Marco-Rius, I, Tayler, MCD, (2023). Real-Time Polarimetry of Hyperpolarized 13C Nuclear Spins Using an Atomic Magnetometer Journal Of Physical Chemistry Letters , 1192-1197

We introduce a method for nondestructive quantification of nuclear spin polarization, of relevance to hyperpolarized spin tracers widely used in magnetic resonance from spectroscopy to in vivo imaging. In a bias field of around 30 nT we use a high-sensitivity miniaturized 87Rb-vapor magnetometer to measure the field generated by the sample, as it is driven by a windowed dynamical decoupling pulse sequence that both maximizes the nuclear spin lifetime and modulates the polarization for easy detection. We demonstrate the procedure applied to a 0.08 M hyperpolarized [1-13C]-pyruvate solution produced by dissolution dynamic nuclear polarization, measuring polarization repeatedly during natural decay at Earth's field. Application to real-time and continuous quality monitoring of hyperpolarized substances is discussed.

JTD Keywords: performance, polarization, Atomic magnetometers, Bias field, High sensitivity, Hyperpolarized, In-vivo imaging, Magnetic resonance, Magnetic-resonance, Magnetic-resonance,polarizatio, Magnetic-resonance,polarization,performanc, Magnetometers, Non destructive, Nuclear spins, Nuclear-spin polarization, Performance, Polarization, Rb vapors, Real- time, Spin dynamics, Spin polarization


Middelhoek, KINA, Magdanz, V, Abelmann, L, Khalil, ISM, (2022). Drug-Loaded IRONSperm clusters: modeling, wireless actuation, and ultrasound imaging Biomedical Materials 17, 65001

Individual biohybrid microrobots have the potential to perform biomedical in vivo tasks such as remote-controlled drug and cell delivery and minimally invasive surgery. This work demonstrates the formation of biohybrid sperm-templated clusters under the influence of an external magnetic field and essential functionalities for wireless actuation and drug delivery. Ferromagnetic nanoparticles are electrostatically assembled around dead sperm cells, and the resulting nanoparticle-coated cells are magnetically assembled into three-dimensional biohybrid clusters. The aim of this clustering is threefold: First, to enable rolling locomotion on a nearby solid boundary using a rotating magnetic field; second, to allow for noninvasive localization; third, to load the cells inside the cluster with drugs for targeted therapy. A magneto-hydrodynamic model captures the rotational response of the clusters in a viscous fluid, and predicts an upper bound for their step-out frequency, which is independent of their volume or aspect ratio. Below the step-out frequency, the rolling velocity of the clusters increases nonlinearly with their perimeter and actuation frequency. During rolling locomotion, the clusters are localized using ultrasound images at a relatively large distance, which makes these biohybrid clusters promising for deep-tissue applications. Finally, we show that the estimated drug load scales with the number of cells in the cluster and can be retained for more than 10 h. The aggregation of microrobots enables them to collectively roll in a predictable way in response to an external rotating magnetic field, and enhances ultrasound detectability and drug loading capacity compared to the individual microrobots. The favorable features of biohybrid microrobot clusters place emphasis on the importance of the investigation and development of collective microrobots and their potential for in vivo applications.

JTD Keywords: drug delivery, magnetic actuation, microrobot aggregation, sperm, Driven, Drug delivery, Magnetic actuation, Magnetotactic bacteria, Microrobot aggregation, Microrobots, Motion, Movement, Propulsion, Sperm, Sphere, Ultrasound, Wall


De Lama-Odría, MD, Del Valle, LJ, Puiggalí, J, (2022). Hydroxyapatite Biobased Materials for Treatment and Diagnosis of Cancer International Journal Of Molecular Sciences 23, 11352

Great advances in cancer treatment have been undertaken in the last years as a consequence of the development of new antitumoral drugs able to target cancer cells with decreasing side effects and a better understanding of the behavior of neoplastic cells during invasion and metastasis. Specifically, drug delivery systems (DDS) based on the use of hydroxyapatite nanoparticles (HAp NPs) are gaining attention and merit a comprehensive review focused on their potential applications. These are derived from the intrinsic properties of HAp (e.g., biocompatibility and biodegradability), together with the easy functionalization and easy control of porosity, crystallinity and morphology of HAp NPs. The capacity to tailor the properties of DLS based on HAp NPs has well-recognized advantages for the control of both drug loading and release. Furthermore, the functionalization of NPs allows a targeted uptake in tumoral cells while their rapid elimination by the reticuloendothelial system (RES) can be avoided. Advances in HAp NPs involve not only their use as drug nanocarriers but also their employment as nanosystems for magnetic hyperthermia therapy, gene delivery systems, adjuvants for cancer immunotherapy and nanoparticles for cell imaging.

JTD Keywords: antitumoral, cancer, cell imaging, controlled-release, drug-carrier, efficient drug-delivery, fatty-acid-metabolism, fe3o4 nanoparticles, gene delivery, hydroxyapatite, hyperthermia, immunotherapy, in-vitro, magnetic hydroxyapatite, nano-hydroxyapatite, protein adsorption, tumor-growth, Calcium-phosphate nanoparticles, Cancer, Immunotherapy


Dias, JMS, Estima, D, Punte, H, Klingner, A, Marques, L, Magdanz, V, Khalil, ISM, (2022). Modeling and Characterization of the Passive Bending Stiffness of Nanoparticle-Coated Sperm Cells using Magnetic Excitation Advanced Theory And Simulations 5, 2100438

Of all the various locomotion strategies in low- (Formula presented.), traveling-wave propulsion methods with an elastic tail are preferred because they can be developed using simple designs and fabrication procedures. The only intrinsic property of the elastic tail that governs the form and rate of wave propagation along its length is the bending stiffness. Such traveling wave motion is performed by spermatozoa, which possess a tail that is characterized by intrinsic variable stiffness along its length. In this paper, the passive bending stiffness of the magnetic nanoparticle-coated flagella of bull sperm cells is measured using a contactless electromagnetic-based excitation method. Numerical elasto-hydrodynamic models are first developed to predict the magnetic excitation and relaxation of nanoparticle-coated nonuniform flagella. Then solutions are provided for various groups of nonuniform flagella with disparate nanoparticle coatings that relate their bending stiffness to their decay rate after the magnetic field is removed and the flagellum restores its original configuration. The numerical models are verified experimentally, and capture the effect of the nanoparticle coating on the bending stiffness. It is also shown that electrostatic self-assembly enables arbitrarily magnetizable cellular segments with variable stiffness along the flagellum. The bending stiffness is found to depend on the number and location of the magnetized cellular segments. © 2022 The Authors. Advanced Theory and Simulations published by Wiley-VCH GmbH.

JTD Keywords: cilia, flagella, flagellar propulsion, low reynolds numbers, magnetic, microswimmers, passive, sperm cell, Bending stiffness, Cells, Cellulars, Coatings, Decay (organic), Electric excitation, Excited states, Flagellar propulsion, Locomotion strategies, Low reynolds numbers, Magnetic, Magnetic excitations, Nanoparticle coatings, Passive, Propulsion methods, Self assembly, Simple++, Sperm cell, Sperm cells, Stiffness, Travelling waves, Variable stiffness, Wave propagation, Younǵs modulus


Murar, M, Albertazzi, L, Pujals, S, (2022). Advanced Optical Imaging-Guided Nanotheranostics toward Personalized Cancer Drug Delivery Nanomaterials 12, 399

Nanomedicine involves the use of nanotechnology for clinical applications and holds promise to improve treatments. Recent developments offer new hope for cancer detection, prevention and treatment; however, being a heterogenous disorder, cancer calls for a more targeted treatment approach. Personalized Medicine (PM) aims to revolutionize cancer therapy by matching the most effective treatment to individual patients. Nanotheranostics comprise a combination of therapy and diagnostic imaging incorporated in a nanosystem and are developed to fulfill the promise of PM by helping in the selection of treatments, the objective monitoring of response and the planning of follow-up therapy. Although well-established imaging techniques, such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Positron Emission Tomography (PET) and Single-Photon Emission Computed Tomography (SPECT), are primarily used in the development of theranostics, Optical Imaging (OI) offers some advantages, such as high sensitivity, spatial and temporal resolution and less invasiveness. Additionally, it allows for multiplexing, using multi-color imaging and DNA barcoding, which further aids in the development of personalized treatments. Recent advances have also given rise to techniques permitting better penetration, opening new doors for OI-guided nanotheranostics. In this review, we describe in detail these recent advances that may be used to design and develop efficient and specific nanotheranostics for personalized cancer drug delivery. © 2022 by the authors. Licensee MDPI, Basel, Switzerland.

JTD Keywords: 5-aminolevulinic acid, cancer, contrast agents, in-vivo, malignant gliomas, multifunctional nanoparticles, nanomedicine, optical imaging, ovarian-cancer, personalized medicine, quantum dots, silica nanoparticles, targeted probes, theranostics, Cancer, Nanomedicine, Optical imaging, Personalized medicine, Superparamagnetic iron-oxide, Theranostics


dos Santos, FP, Verschure, PFMJ, (2022). Excitatory-Inhibitory Homeostasis and Diaschisis: Tying the Local and Global Scales in the Post-stroke Cortex Frontiers In Systems Neuroscience 15, 806544

Maintaining a balance between excitatory and inhibitory activity is an essential feature of neural networks of the neocortex. In the face of perturbations in the levels of excitation to cortical neurons, synapses adjust to maintain excitatory-inhibitory (EI) balance. In this review, we summarize research on this EI homeostasis in the neocortex, using stroke as our case study, and in particular the loss of excitation to distant cortical regions after focal lesions. Widespread changes following a localized lesion, a phenomenon known as diaschisis, are not only related to excitability, but also observed with respect to functional connectivity. Here, we highlight the main findings regarding the evolution of excitability and functional cortical networks during the process of post-stroke recovery, and how both are related to functional recovery. We show that cortical reorganization at a global scale can be explained from the perspective of EI homeostasis. Indeed, recovery of functional networks is paralleled by increases in excitability across the cortex. These adaptive changes likely result from plasticity mechanisms such as synaptic scaling and are linked to EI homeostasis, providing a possible target for future therapeutic strategies in the process of rehabilitation. In addition, we address the difficulty of simultaneously studying these multiscale processes by presenting recent advances in large-scale modeling of the human cortex in the contexts of stroke and EI homeostasis, suggesting computational modeling as a powerful tool to tie the meso- and macro-scale processes of recovery in stroke patients. Copyright © 2022 Páscoa dos Santos and Verschure.

JTD Keywords: balanced excitation, canonical microcircuit, cerebral-cortex, cortical excitability, cortical reorganization, diaschisis, excitability, excitatory-inhibitory balance, functional networks, homeostatic plasticity, ischemic-stroke, neuronal avalanches, photothrombotic lesions, state functional connectivity, whole-brain models, Algorithm, Biological marker, Brain, Brain cell, Brain cortex, Brain function, Brain radiography, Cerebrovascular accident, Cortical reorganization, Diaschisis, Down regulation, Excitability, Excitatory-inhibitory balance, Fluorine magnetic resonance imaging, Functional networks, Homeostasis, Homeostatic plasticity, Human, Motor dysfunction, Neuromodulation, Plasticity, Pyramidal nerve cell, Review, Simulation, Stroke, Stroke patient, Theta-burst stimulation, Visual cortex


Puiggalí-Jou, A, Babeli, I, Roa, JJ, Zoppe, JO, Garcia-Amorós, J, Ginebra, MP, Alemán, C, García-Torres, J, (2021). Remote Spatiotemporal Control of a Magnetic and Electroconductive Hydrogel Network via Magnetic Fields for Soft Electronic Applications Acs Applied Materials & Interfaces 13, 42486-42501

Multifunctional hydrogels are a class of materials offering new opportunities for interfacing living organisms with machines due to their mechanical compliance, biocompatibility, and capacity to be triggered by external stimuli. Here, we report a dual magnetic- and electric-stimuli-responsive hydrogel with the capacity to be disassembled and reassembled up to three times through reversible cross-links. This allows its use as an electronic device (e.g., temperature sensor) in the cross-linked state and spatiotemporal control through narrow channels in the disassembled state via the application of magnetic fields, followed by reassembly. The hydrogel consists of an interpenetrated polymer network of alginate (Alg) and poly(3,4-ethylenedioxythiophene) (PEDOT), which imparts mechanical and electrical properties, respectively. In addition, the incorporation of magnetite nanoparticles (Fe3O4 NPs) endows the hydrogel with magnetic properties. After structural, (electro)chemical, and physical characterization, we successfully performed dynamic and continuous transport of the hydrogel through disassembly, transporting the polymer-Fe3O4 NP aggregates toward a target using magnetic fields and its final reassembly to recover the multifunctional hydrogel in the cross-linked state. We also successfully tested the PEDOT/Alg/Fe3O4 NP hydrogel for temperature sensing and magnetic hyperthermia after various disassembly/re-cross-linking cycles. The present methodology can pave the way to a new generation of soft electronic devices with the capacity to be remotely transported.

JTD Keywords: conductive hydrogel, constructs, magnetic field, magnetite nanoparticle, nanoindentation, soft electronics, spatiotemporal control, Conductive hydrogel, Conductive hydrogels, Magnetic field, Magnetite nanoparticle, Soft electronics, Spatiotemporal control


Apriceno, A, Silvestro, I, Girelli, A, Francolini, I, Pietrelli, L, Piozzi, A, (2021). Preparation and characterization of chitosan-coated manganese-ferrite nanoparticles conjugated with laccase for environmental bioremediation Polymers 13, 1453

Bioremediation with immobilized enzymes has several advantages, such as the enhancement of selectivity, activity, and stability of biocatalysts, as well as enzyme reusability. Laccase has proven to be a good candidate for the removal of a wide range of contaminants. In this study, naked or modified MnFe O magnetic nanoparticles (MNPs) were used as supports for the immobilization of laccase from Trametes versicolor. To increase enzyme loading and stability, MNPs were coated with chitosan both after the MNP synthesis (MNPs-CS) and during their formation (MNPs-CS ). SEM analysis showed different sizes for the two coated systems, 20 nm and 10 nm for MNPs-CS and MNPs-CS , respectively. After covalent immobilization of laccase by glutaraldehyde, the MNPs-CS -lac and MNPs-CS-lac systems showed a good resistance to temperature denaturation and storage stability. The most promising system for use in repeated batches was MNPs-CS -lac, which degraded about 80% of diclofenac compared to 70% of the free enzyme. The obtained results demonstrated that the MnFe O -CS system could be an excellent candidate for the removal of contaminants. 2 4 in situ in situ in situ in situ 2 4 in situ

JTD Keywords: bioremediation, chitosan, diclofenac, diclofenac removal, immobilized enzyme, laccase, magnetic nanoparticles, phase, removal, supports, Bioremediation, Chitosan, Diclofenac removal, Enzyme immobilization, Immobilized enzyme, Laccase, Magnetic nanoparticles


Magdanz, V, Vivaldi, J, Mohanty, S, Klingner, A, Vendittelli, M, Simmchen, J, Misra, S, Khalil, ISM, (2021). Impact of Segmented Magnetization on the Flagellar Propulsion of Sperm-Templated Microrobots Advanced Science 8, 2004037

© 2021 The Authors. Advanced Science published by Wiley-VCH GmbH Technical design features for improving the way a passive elastic filament produces propulsive thrust can be understood by analyzing the deformation of sperm-templated microrobots with segmented magnetization. Magnetic nanoparticles are electrostatically self-assembled on bovine sperm cells with nonuniform surface charge, producing different categories of sperm-templated microrobots. Depending on the amount and location of the nanoparticles on each cellular segment, magnetoelastic and viscous forces determine the wave pattern of each category during flagellar motion. Passively propagating waves are induced along the length of these microrobots using external rotating magnetic fields and the resultant wave patterns are measured. The response of the microrobots to the external field reveals distinct flow fields, propulsive thrust, and frequency responses during flagellar propulsion. This work allows predictions for optimizing the design and propulsion of flexible magnetic microrobots with segmented magnetization.

JTD Keywords: biohybrid microrobots, flagellar propulsion, magnetic actuation, nanoparticles, sperm cells, Biohybrid microrobots, Flagellar propulsion, Magnetic actuation, Nanoparticles, Sperm cells


Ebrahimi, N, Bi, CH, Cappelleri, DJ, Ciuti, G, Conn, AT, Faivre, D, Habibi, N, Hosovsky, A, Iacovacci, V, Khalil, ISM, Magdanz, V, Misra, S, Pawashe, C, Rashidifar, R, Soto-Rodriguez, PED, Fekete, Z, Jafari, A, (2021). Magnetic Actuation Methods in Bio/Soft Robotics Advanced Functional Materials 31, 2005137

© 2020 Wiley-VCH GmbH In recent years, magnetism has gained an enormous amount of interest among researchers for actuating different sizes and types of bio/soft robots, which can be via an electromagnetic-coil system, or a system of moving permanent magnets. Different actuation strategies are used in robots with magnetic actuation having a number of advantages in possible realization of microscale robots such as bioinspired microrobots, tetherless microrobots, cellular microrobots, or even normal size soft robots such as electromagnetic soft robots and medical robots. This review provides a summary of recent research in magnetically actuated bio/soft robots, discussing fabrication processes and actuation methods together with relevant applications in biomedical area and discusses future prospects of this way of actuation for possible improvements in performance of different types of bio/soft robots.

JTD Keywords: capsule endoscope, controlled propulsion, conventional gastroscopy, digital microfluidics, guided capsule, liquid-metal, magnetic drug delivery, magnetic microrobots, magnetically guided capsule endoscopy, magnetotactic bacteria, nanoscribe ip-dip, navigation system, Gallium-indium egain, Magnetic bioinspired micromanipulation, Magnetic drug delivery, Magnetic microrobots, Magnetically guided capsule endoscopy, Magnetotactic bacteria


Hernández-Albors, Alejandro, Castaño, Albert G., Fernández-Garibay, Xiomara, Ortega, María Alejandra, Balaguer, Jordina, Ramón-Azcón, Javier, (2019). Microphysiological sensing platform for an in-situ detection of tissue-secreted cytokines Biosensors and Bioelectronics: X 2, 100025

Understanding the protein-secretion dynamics from single, specific tissues is critical toward the advancement of disease detection and treatments. However, such secretion dynamics remain difficult to measure in vivo due to the uncontrolled contributions from other tissue populations. Here, we describe an integrated platform designed for the reliable, near real-time measurements of cytokines secreted from an in vitro single-tissue model. In our setup, we grow 3D biomimetic tissues to discretize cytokine source, and we separate them from a magnetic microbead-based biosensing system using a Transwell insert. This design integrates physiochemically controlled biological activity, high-sensitivity protein detection (LOD < 20 pg mL−1), and rapid protein diffusion to enable non-invasive, near real-time measurements. To showcase the specificity and sensitivity of the system, we use our setup to probe the inflammatory process related to the protein Interleukine 6 (IL-6) and to the Tumor Necrosis Factor (TNF-α). We show that our setup can monitor the time-dependence profile of IL-6 and TNF-α secretion that results from the electrical and chemical stimulation of 3D skeletal muscle tissues. We demonstrate a novel and affordable methodology for discretizing the secretion kinetics of specific tissues for advancing metabolic-disorder studies and drug-screening applications.

JTD Keywords: Microphysiological tissues, Tissue engineering, Electrochemical, biosensors, Magnetic particles, Skeletal muscle, Electric stimulation


Faron, A., Pieper, C. C., Schmeel, F. C., Sprinkart, A. M., Kuetting, D. L. R., Fimmers, R., Trebicka, J., Schild, H. H., Meyer, C., Thomas, D., Luetkens, J. A., (2019). Fat-free muscle area measured by magnetic resonance imaging predicts overall survival of patients undergoing radioembolization of colorectal cancer liver metastases European Radiology 29, (9), 4709-4717

Objectives: To investigate the clinical potential of fat-free muscle area (FFMA) to predict outcome in patients with liver-predominant metastatic colorectal cancer (mCRC) undergoing radioembolization (RE) with 90Yttrium microspheres. Methods: Patients with mCRC who underwent RE in our center were included in this retrospective study. All patients received liver magnetic resonance imaging including standard T2-weighted images. The total erector spinae muscle area and the intramuscular adipose tissue area were measured at the level of the origin of the superior mesenteric artery and subtracted to calculate FFMA. Cutoff values for definition of low FFMA were 3644 mm2 in men and 2825 mm2 in women. The main outcome was overall survival (OS). For survival analysis, the Kaplan-Meier method and Cox regressions comparing various clinic-oncological parameters which potentially may affect OS were performed. Results: Seventy-seven patients (28 female, mean age 60 ± 11 years) were analyzed. Mean time between MRI and the following RE was 17 ± 31 days. Median OS after RE was 178 days. Patients with low FFMA had significantly shortened OS compared to patients with high FFMA (median OS: 128 vs. 273 days, p = 0.017). On multivariate Cox regression analysis, OS was best predicted by FFMA (hazard ratio (HR) 2.652; p < 0.001). Baseline bilirubin (HR 1.875; p = 0.030), pattern of tumor manifestation (HR 1.679; p = 0.001), and model of endstage liver disease (MELD) score (HR 1.164; p < 0.001) were also significantly associated with OS. Conclusions: FFMA was associated with OS in patients receiving RE for treatment of mCRC and might be a new prognostic biomarker for survival prognosis.

JTD Keywords: Brachytherapy, Colorectal cancer, Magnetic resonance imaging, Sarcopenia


Villa, Katherine, Parmar, Jemish, Vilela, Diana, Sánchez, Samuel, (2018). Metal-oxide-based microjets for the simultaneous removal of organic pollutants and heavy metals ACS Applied Materials and Interfaces 10, (24), 20478-20486

Water contamination from industrial and anthropogenic activities is nowadays a major issue in many countries worldwide. To address this problem, efficient water treatment technologies are required. Recent efforts have focused on the development of self-propelled micromotors that provide enhanced micromixing and mass transfer by the transportation of reactive species, resulting in higher decontamination rates. However, a real application of these micromotors is still limited due to the high cost associated to their fabrication process. Here, we present Fe2O3-decorated SiO2/MnO2 microjets for the simultaneous removal of industrial organic pollutants and heavy metals present in wastewater. These microjets were synthesized by low-cost and scalable methods. They exhibit an average speed of 485 ± 32 μm s–1 (∼28 body length per s) at 7% H2O2, which is the highest reported for MnO2-based tubular micromotors. Furthermore, the photocatalytic and adsorbent properties of the microjets enable the efficient degradation of organic pollutants, such as tetracycline and rhodamine B under visible light irradiation, as well as the removal of heavy metal ions, such as Cd2+ and Pb2+.

JTD Keywords: Micromotors, Photocatalytic, Water purification, Fenton, Magnetic control, Iron oxide, Manganese oxide


Sehgal, Poonam, Kong, Xinyu, Wu, Jun, Sunyer, Raimon, Trepat, Xavier, Leckband, Deborah, (2018). Epidermal growth factor receptor and integrins control force-dependent vinculin recruitment to E-cadherin junctions Journal of Cell Science 131, (6), jcs206656

This study reports novel findings that link E-cadherin (also known as CDH1)-mediated force-transduction signaling to vinculin targeting to intercellular junctions via epidermal growth factor receptor (EGFR) and integrins. These results build on previous findings that demonstrated that mechanically perturbed E-cadherin receptors activate phosphoinositide 3-kinase and downstream integrins in an EGFR-dependent manner. Results of this study show that this EGFR-mediated kinase cascade controls the force-dependent recruitment of vinculin to stressed E-cadherin complexes – a key early signature of cadherin-based mechanotransduction. Vinculin targeting requires its phosphorylation at tyrosine 822 by Abl family kinases (hereafter Abl), but the origin of force-dependent Abl activation had not been identified. We now present evidence that integrin activation, which is downstream of EGFR signaling, controls Abl activation, thus linking E-cadherin to Abl through a mechanosensitive signaling network. These findings place EGFR and integrins at the center of a positive-feedback loop, through which force-activated E-cadherin signals regulate vinculin recruitment to cadherin complexes in response to increased intercellular tension.This article has an associated First Person interview with the first author of the paper.

JTD Keywords: Cadherin, Epidermal growth factor receptor, Force transduction, Magnetic twisting cytometry, Vinculin, Integrin


Vilela, D., Stanton, M. M., Parmar, J., Sánchez, S., (2017). Microbots decorated with silver nanoparticles kill bacteria in aqueous media ACS Applied Materials & Interfaces 9, (27), 22093-22100

Water contamination is one of the most persistent problems of public health. Resistance of some pathogens to conventional disinfectants can require the combination of multiple disinfectants or increased disinfectant doses, which may produce harmful byproducts. Here, we describe an efficient method for disinfecting Escherichia coli and removing the bacteria from contaminated water using water self-propelled Janus microbots decorated with silver nanoparticles (AgNPs). The structure of a spherical Janus microbot consists of a magnesium (Mg) microparticle as a template that also functions as propulsion source by producing hydrogen bubbles when in contact with water, an inner iron (Fe) magnetic layer for their remote guidance and collection, and an outer AgNP-coated gold (Au) layer for bacterial adhesion and improving bactericidal properties. The active motion of microbots increases the chances of the contact of AgNPs on the microbot surface with bacteria, which provokes the selective Ag+ release in their cytoplasm, and the microbot self-propulsion increases the diffusion of the released Ag+ ions. In addition, the AgNP-coated Au cap of the microbots has a dual capability of capturing bacteria and then killing them. Thus, we have demonstrated that AgNP-coated Janus microbots are capable of efficiently killing more than 80% of E. coli compared with colloidal AgNPs that killed only less than 35% of E. coli in contaminated water solutions in 15 min. After capture and extermination of bacteria, magnetic properties of the cap allow collection of microbots from water along with the captured dead bacteria, leaving water with no biological contaminants. The presented biocompatible Janus microbots offer an encouraging method for rapid disinfection of water.

JTD Keywords: Bactericidal, Magnetic control, Micromotors, Microswimmers, Self-propulsion, Silver nanoparticles


Li, Haiyue, Xu, Bin, Zhou, Enhua H., Sunyer, Raimon, Zhang, Yanhang, (2017). Multiscale measurements of the mechanical properties of collagen matrix ACS Biomaterials Science & Engineering 3, (11), 2815-2824

The underlying mechanisms by which extracellular matrix (ECM) mechanics influences cell and tissue function remain to be elucidated because the events associated with this process span size scales from tissue to molecular level. Furthermore, ECM has an extremely complex hierarchical 3D structure and the load distribution is highly dependent on the architecture and mechanical properties of ECM. In the present study, the macro- and microscale mechanical properties of collagen gel were studied. Dynamic rheological testing was performed to study the macroscale mechanical properties of collagen gel. The microscale mechanical properties of collagen gel were measured using optical magnetic twisting cytometry (OMTC). Ferromagnetic beads embedded in the matrix were used as mechanical probes. Our study on the multiscale mechanical properties of collage matrix suggests several interesting differences between macro and microscale mechanical properties originated from the scales of measurements. At the macroscopic scale, storage and loss modulus increase with collagen concentrations. Nonaffine collagen fibril structural network deformation plays an important role in determining the macroscopic mechanical properties of the collagen matrix. At the microscopic scale, however, the local mechanical properties are less sensitive to changes in collagen concentration because of the more immediate/direct deformation of collagen fibrils in the OMTC measurements through forces exerted by locally attached ferromagnetic beads. The loss modulus is more affected by the local interstitial fluid environment, leading to a rather dramatic increase in viscosity with frequency, especially at higher frequencies (>10 Hz). A finite element model was developed to study the geometric factors in the OMTC measurements when the collagen matrix was considered to be hyperelastic. Our results show that the geometric factors are dependent on collagen concentration, or the stiffness of matrix, when nonlinear material properties of the matrix are considered, and thus interpretation of the apparent modulus from OMTC measurements should be conducted carefully.

JTD Keywords: Keywords: collagen, Extracellular matrix, Geometric factor, Nonaffine deformation, Optical magnetic twisting cytometry


Wang, Y., van Merwyk, L., Tönsing, K., Walhorn, V., Anselmetti, D., Fernàndez-Busquets, X., (2017). Biophysical characterization of the association of histones with single-stranded DNA Biochimica et Biophysica Acta (BBA) - General Subjects , 1861, (11), 2739-2749

Background: Despite the profound current knowledge of the architecture and dynamics of nucleosomes, little is known about the structures generated by the interaction of histones with single-stranded DNA (ssDNA), which is widely present during replication and transcription. Methods: Non-denaturing gel electrophoresis, transmission electron microscopy, atomic force microscopy, magnetic tweezers. Results: Histones have a high affinity for ssDNA in 0.15 M NaCl ionic strength, with an apparent binding constant similar to that calculated for their association with double-stranded DNA (dsDNA). The length of DNA (number of nucleotides in ssDNA or base pairs in dsDNA) associated with a fixed core histone mass is the same for both ssDNA and dsDNA. Although histone-ssDNA complexes show a high tendency to aggregate, nucleosome-like structures are formed at physiological salt concentrations. Core histones are able to protect ssDNA from digestion by micrococcal nuclease, and a shortening of ssDNA occurs upon its interaction with histones. The purified (+) strand of a cloned DNA fragment of nucleosomal origin has a higher affinity for histones than the purified complementary (−) strand. Conclusions: At physiological ionic strength histones have high affinity for ssDNA, possibly associating with it into nucleosome-like structures. General significance: In the cell nucleus histones may spontaneously interact with ssDNA to facilitate their participation in the replication and transcription of chromatin.

JTD Keywords: Electrophoresis, Force spectroscopy, Histones, Magnetic tweezers, Nucleosome, Single-stranded DNA


Ballester, Rubio Belén, Nirme, Jens, Camacho, Irene, Duarte, Esther, Rodríguez, Susana, Cuxart, Ampar, Duff, Armin, Verschure, F. M. J. Paul, (2017). Domiciliary VR-based therapy for functional recovery and cortical reorganization: Randomized controlled trial in participants at the chronic stage post stroke JMIR Serious Games , 5, (3), e15

Background: Most stroke survivors continue to experience motor impairments even after hospital discharge. Virtual reality-based techniques have shown potential for rehabilitative training of these motor impairments. Here we assess the impact of at-home VR-based motor training on functional motor recovery, corticospinal excitability and cortical reorganization. Objective: The aim of this study was to identify the effects of home-based VR-based motor rehabilitation on (1) cortical reorganization, (2) corticospinal tract, and (3) functional recovery after stroke in comparison to home-based occupational therapy. Methods: We conducted a parallel-group, controlled trial to compare the effectiveness of domiciliary VR-based therapy with occupational therapy in inducing motor recovery of the upper extremities. A total of 35 participants with chronic stroke underwent 3 weeks of home-based treatment. A group of subjects was trained using a VR-based system for motor rehabilitation, while the control group followed a conventional therapy. Motor function was evaluated at baseline, after the intervention, and at 12-weeks follow-up. In a subgroup of subjects, we used Navigated Brain Stimulation (NBS) procedures to measure the effect of the interventions on corticospinal excitability and cortical reorganization. Results: Results from the system?s recordings and clinical evaluation showed significantly greater functional recovery for the experimental group when compared with the control group (1.53, SD 2.4 in Chedoke Arm and Hand Activity Inventory). However, functional improvements did not reach clinical significance. After the therapy, physiological measures obtained from a subgroup of subjects revealed an increased corticospinal excitability for distal muscles driven by the pathological hemisphere, that is, abductor pollicis brevis. We also observed a displacement of the centroid of the cortical map for each tested muscle in the damaged hemisphere, which strongly correlated with improvements in clinical scales. Conclusions: These findings suggest that, in chronic stages, remote delivery of customized VR-based motor training promotes functional gains that are accompanied by neuroplastic changes. Trial Registration: International Standard Randomized Controlled Trial Number NCT02699398 (Archived by ClinicalTrials.gov at https://clinicaltrials.gov/ct2/show/NCT02699398?term=NCT02699398&rank=1)

JTD Keywords: Stroke, Movement disorder, Recovery of function, neuroplasticity, Transcranial magnetic stimulation, Physical therapy, Hemiparesis, Computer applications software


Seo, K. D., Kwak, B. K., Sánchez, S., Kim, D. S., (2015). Microfluidic-assisted fabrication of flexible and location traceable organo-motor IEEE Transactions on Nanobioscience , 14, (3), 298-304

In this paper, we fabricate a flexible and location traceable micromotor, called organo-motor, assisted by microfluidic devices and with high throughput. The organo-motors are composed of organic hydrogel material, poly (ethylene glycol) diacrylate (PEGDA), which can provide the flexibility of their structure. For spatial and temporal traceability of the organo-motors under magnetic resonance imaging (MRI), superparamagnetic iron oxide nanoparticles (SPION; Fe3O4) were incorporated into the PEGDA microhydrogels. Furthermore, a thin layer of platinum (Pt) was deposited onto one side of the SPION-PEGDA microhydrogels providing geometrical asymmetry and catalytic propulsion in aqueous fluids containing hydrogen peroxide solution, H2O2. Furthermore, the motion of the organo-motor was controlled by a small external magnet enabled by the presence of SPION in the motor architecture.

JTD Keywords: Flexible, Hydrogel, Magnetic resonance imaging, Microfluidics, Micromotor, Microparticle, Organo-motor, Poly (ethylene glycol) diacrylate, Self-propulsion, Superparamagnetic iron oxide nanoparticles


Khalil, I. S. M., Magdanz, V., Sánchez, S., Schmidt, O. G., Misra, S., (2015). Precise localization and control of catalytic janus micromotors using weak magnetic fields International Journal of Advanced Robotic Systems , 12, (2), 1-7

We experimentally demonstrate the precise localization of spherical Pt-Silica Janus micromotors (diameter 5 μm) under the influence of controlled magnetic fields. First, we control the motion of the Janus micromotors in two-dimensional (2D) space. The control system achieves precise localization within an average region-of-convergence of 7 μm. Second, we show that these micromotors provide sufficient propulsion force, allowing them to overcome drag and gravitational forces and move both downwards and upwards. This propulsion is studied by moving the micromotors in three-dimensional (3D) space. The micromotors move downwards and upwards at average speeds of 19.1 μm/s and 9.8 μm/s, respectively. Moreover, our closed-loop control system achieves localization in 3D space within an average region-of-convergence of 6.3 μm in diameter. The precise motion control and localization of the Janus micromotors in 2D and 3D spaces provides broad possibilities for nanotechnology applications.

JTD Keywords: 3D space, Localization, Magnetic control, Micromotors, Self-propulsion


Oliva, A. M., Homs, A., Torrents, E., Juarez, A., Samitier, J., (2014). Effect of electric field and temperature in E.Coli viability IFMBE Proceedings XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013 (ed. Roa Romero, Laura M.), Springer (Seville, Spain) 41, 1833-1836

Electromagnetic Fields are increasingly used to manipulate bacteria. However, there is no systematic and definitive study on how the different electric parameters change bacteria viability. Here we present preliminary data on the effect of electric field intensity and temperature applica- tion. E. Coli colonies have been exposed to different voltages at 1MHz during 5 minutes by means of a custom-made micro- fluidic device. Results show that E.Coli survival rate is already reduced by applying field intensities as low as 220V/cm during 5 minutes. The use of stronger fields resulted in death rates increase also. Viability of survived bacteria was maintained. On the other hand, temperature has shown a synergistic effect with voltage. When temperature is increased results seem to indicate stronger sensitivity of cells to the electric field. It is necessary to continue studying the contribution of other para- meters as intensity, time, frequency or concentration, to study further synergies.

JTD Keywords: E. Coli, Electromagnetic Field, Temperature, Viability


Riggio, C., Nocentini, S., Catalayud, M. P., Goya, G. F., Cuschieri, A., Raffa, V., del Río, J. A., (2013). Generation of magnetized olfactory ensheathing cells for regenerative studies in the central and peripheral nervous tissue International Journal of Molecular Sciences 14, (6), 10852-10868

As olfactory receptor axons grow from the peripheral to the central nervous system (CNS) aided by olfactory ensheathing cells (OECs), the transplantation of OECs has been suggested as a plausible therapy for spinal cord lesions. The problem with this hypothesis is that OECs do not represent a single homogeneous entity, but, instead, a functionally heterogeneous population that exhibits a variety of responses, including adhesion and repulsion during cell-matrix interactions. Some studies report that the migratory properties of OECs are compromised by inhibitory molecules and potentiated by chemical gradients. In this paper, we report a system based on modified OECs carrying magnetic nanoparticles as a proof of concept experiment enabling specific studies aimed at exploring the potential of OECs in the treatment of spinal cord injuries. Our studies have confirmed that magnetized OECs (i) survive well without exhibiting stress-associated cellular responses; (ii) in vitro, their migration can be modulated by magnetic fields; and (iii) their transplantation in organotypic slices of spinal cord and peripheral nerve showed positive integration in the model. Altogether, these findings indicate the therapeutic potential of magnetized OECs for CNS injuries.

JTD Keywords: Magnetic nanoparticle, Nerve regeneration, Olfactory ensheathing cell, Organotypic culture


Mir, Mònica , Tahirbegi, Islam Bogachan , Valle-Delgado, Juan José , Fernàndez-Busquets, X., Samitier, Josep , (2012). In vitro study of magnetite-amyloid β complex formation Nanomedicine: Nanotechnology, Biology, and Medicine 8, (6), 974-980

Biogenic magnetite (Fe3O4) has been identified in human brain tissue. However, abnormal concentration of magnetite nanoparticles in the brain has been observed in different neurodegenerative pathologies. In the case of Alzheimer's disease (AD), these magnetic nanoparticles have been identified attached to the characteristic brain plaques, which are mainly formed by fibrils of amyloid β peptide (Aβ). However, few clues about the formation of the magnetite-Aβ complex have been reported. We have investigated the interaction between these important players in the AD with superconducting quantum interference, scanning electron microscope, surface plasmon resonance, and magnetic force microscopy. The results support the notion that the magnetite-Aβ complex is created before the synthesis of the magnetic nanoparticles, bringing a highly stable interaction of this couple.

JTD Keywords: Alzheimer's disease, Biogenic magnetite, Amyloid β peptide (Aβ), Superconducting quantum interference, Scanning electron microscope, Surface plasmon resonance, Magnetic force microscopy


Ivon Rodriguez-Villarreal, Angeles, Tarn, Mark D., Madden, Leigh A., Lutz, Julia B., Greenman, John, Samitier, Josep, Pamme, Nicole, (2011). Flow focussing of particles and cells based on their intrinsic properties using a simple diamagnetic repulsion setup Lab on a Chip 11, (7), 1240-1248

The continuous flow focussing and manipulation of particles and cells are important factors in microfluidic applications for performing accurate and reproducible procedures downstream. Many particle focussing methods require complex setups or channel designs that can limit the process and its applications. Here, we present diamagnetic repulsion as a simple means of focussing objects in continuous flow, based only on their intrinsic properties without the requirement of any label. Diamagnetic polystyrene particles were suspended in a paramagnetic medium and pumped through a capillary between a pair of permanent magnets, whereupon the particles were repelled by each magnet into the central axis of the capillary, thus achieving focussing. By investigating this effect, we found that the focussing was greatly enhanced with (i) increased magnetic susceptibility of the medium, (ii) reduced flow rate of the suspension, (iii) increased particle size, and (iv) increased residence time in the magnetic field. Furthermore, we applied diamagnetic repulsion to the flow focussing of living, label-free HaCaT cells.

JTD Keywords: Feeble magnetic substances, On-chip, Blood-cells, Microfluidic device, Separation, Field, Levitation, Magnetophoresis, Fractionation, Nanoparticles


Puig, F., Gavara, N., Sunyer, R., Carreras, A., Farre, R., Navajas, D., (2009). Stiffening and contraction induced by dexamethasone in alveolar epithelial cells Experimental Mechanics , 49, (1), 47-55

The structural integrity of the alveolar monolayer, which is compromised during lung inflammation, is determined by the balance between cell-cell and cell-matrix tethering forces and the centripetal forces owing to cell viscoelasticity and contraction. Dexamethasone is an anti-inflammatory glucocorticoid with protective effects in lung injury. To determine the effects of Dexamethasone on the stiffness and contractility of alveolar epithelial cells. Cell stiffness (G') and average traction exerted by the cell (T) were measured by magnetic twisting cytometry and by traction microscopy, respectively. A549 cells were treated 24 h with Dexamethasone (1 mu M) or vehicle (control). G' and T were measured before and 5 min after challenge with the inflammatory mediator Thrombin (0.5 U/ml). Changes induced by Dexamethasone in actin cytoskeleton polymerization were assessed by the fluorescent ratio between F-actin and G-actin obtained by staining cells with phalloidin and DNase I. Dexamethasone significantly increased G' and T by 56% (n = 11; p < 0.01) and by 80% (n = 17; p < 0.05), respectively. Dexamethasone also increased F/G-actin ratio from 2.68 +/- 0.07 to 2.96 +/- 0.09 (n = 10; p < 0.05). The relative increase in stiffness and contraction induced by Thrombin in control cells was significantly (p < 0.05) reduced by Dexamethasone treatment: from 190 to 98% in G' and from 318 to 105% in T. The cytoskeleton remodelling and the increase in cell stiffness and contraction induced by Dexamethasone could account for its protective effect in the alveolar epithelium when subjected to inflammatory challenge.

JTD Keywords: Cell mechanics, Cytoskeleton, Magnetic twisting cytometry, Traction microscopy, Respiratory diseases