DONATE

Publications

by Keyword: Electrodes

Borras, N, Sanchez-Sanz, A, Sans, J, Estrany, F, Perez-Madrigal, MM, Aleman, C, (2023). Flexible electroactive membranes for the electrochemical detection of dopamine European Polymer Journal 187, 111915

In addition of a key catecholamine neurotransmitter, dopamine is is the metabolite predominantly produced by specific types of tumors (e.g. paragangliomas and neuroblastomas), which cannot be diagnosed using conven-tional sensitive tests. Within this context, development of flexible electrochemical sensors to monitor dopamine levels in physiological fluids for the early diagnosis and control of diseases related to abnormal levels of such compound, is necessary. In this work, a flexible self-supported membrane, which acts directly as electrode, has been developed to detect dopamine. The membrane consists of three nanoperforated polylactic acid (PLA) layers, which provide flexibility and mechanical integrity, separated by two layers of an electroactive copolymer, which are obtained by electrochemical copolymerization of 3,4-ethylenedioxythiophene and aniline. The sensitivity and detection limit provided by the electroactive copolymer, which is accessible to dopamine molecules through the nanoperforations of the PLA outer layers, is 1.846 mu A/(cm2.mu M) and 1.7 mu M, respectively, in a urea-rich environments that mimics urine. These values allow us to propose the self-standing flexible electrodes devel-oped in this study for the detection of dopamine in patients affected by paragangliomas and neuroblastomas tumors, which typically present dopamine concentrations between 2 and 7 mu M.

JTD Keywords: 4-ethylenedioxythiophene), Conducting polymer, Electrochemical sensor, Electrodes, Hydrogels, Poly(3, Polyaniline, Polylactic acid, Selective detection, Sensors, Supercapacitors


Munoz-Galan, H, Molina, BG, Bertran, O, Perez-Madrigal, MM, Aleman, C, (2022). Combining rapid and sustained insulin release from conducting hydrogels for glycemic control br European Polymer Journal 181, 111670

Innovative insulin delivery systems contemplate combining multi-pharmacokinetic profiles for glycemic control. Two device configurations have been designed for the controlled release of insulin using the same chemical compounds. The first insulin delivery system, which displays a rapid release response that, in addition, is enhanced on a short time scale by electrical stimulation, consists on an insulin layer sandwiched between a conducting poly(3,4-ethylenedioxythiophene) (PEDOT) film and a poly-gamma-glutamic acid (gamma-PGA) hydrogel. The second system is constituted by gamma-PGA hydrogel loaded with insulin and PEDOT nanoparticles by in situ gelation. In this case, the insulin release, which only starts after the degradation of the hydrogel over time (i.e. on a long time scale), is slow and sustained. The combination of an on-demand and fast release profile with a sustained and slow profile, which act on different time scales, would result in a very efficient regulation of diabetes therapy in comparison to current systems, allowing to control both fast and sustained glycemic events. Considering that the two systems developed in this work are based on the same chemical components, future work will be focused on the combination of the two kinetic profiles by re-engineering a unique insulin release device using gamma-PGA, PEDOT and insulin.

JTD Keywords: Conducting polymer, Constant, Diabetes, Diabetes-mellitus, Drug-delivery, Electrodes, Electrostimulation, Glucose-responsive hydrogels, Hydrogel, Molecular dynamics, Molecular-dynamics, Nanogels, Nanoparticles, Poly(3,4-ethylenedioxythiophene), Risk


Fontana-Escartín, A, Lanzalaco, S, Pérez-Madrigal, MM, Bertran, O, Alemán, C, (2022). Electrochemical activation for sensing of three‐dimensional‐printed poly(lactic acid) using low‐pressure plasma Plasma Processes And Polymers 19, e2200101

García-Torres, J, Colombi, S, Macor, LP, Alemán, C, (2022). Multitasking smart hydrogels based on the combination of alginate and poly(3,4-ethylenedioxythiophene) properties: A review International Journal Of Biological Macromolecules 219, 312-332

Poly(3,4-ethylenedioxythiophene) (PEDOT), a very stable and biocompatible conducting polymer, and alginate (Alg), a natural water-soluble polysaccharide mainly found in the cell wall of various species of brown algae, exhibit very different but at the same complementary properties. In the last few years, the remarkable capacity of Alg to form hydrogels and the electro-responsive properties of PEDOT have been combined to form not only layered composites (PEDOT-Alg) but also interpenetrated multi-responsive PEDOT/Alg hydrogels. These materials have been found to display outstanding properties, such as electrical conductivity, piezoelectricity, biocompatibility, self-healing and re-usability properties, pH and thermoelectric responsiveness, among others. Consequently, a wide number of applications are being proposed for PEDOT-Alg composites and, especially, PEDOT/Alg hydrogels, which should be considered as a new kind of hybrid material because of the very different chemical nature of the two polymeric components. This review summarizes the applications of PEDOT-Alg and PEDOT/Alg in tissue interfaces and regeneration, drug delivery, sensors, microfluidics, energy storage and evaporators for desalination. Special attention has been given to the discussion of multi-tasking applications, while the new challenges to be tackled based on aspects not yet considered in either of the two polymers have also been highlighted.Copyright © 2022 The Authors. Published by Elsevier B.V. All rights reserved.

JTD Keywords: aerogels, composite, conducting polymer, conducting polymers, electrodes, pedotpss, ph, platform, release, scaffold, semi-interpenetrated hydrogels, Alginic acid, Conducting polymer, Drug-delivery, Semi-interpenetrated hydrogels


López-Ortiz, M, Zamora, RA, Giannotti, MI, Hu, C, Croce, R, Gorostiza, P, (2022). Distance and Potential Dependence of Charge Transport Through the Reaction Center of Individual Photosynthetic Complexes Small 18, 2104366

Charge separation and transport through the reaction center of photosystem I (PSI) is an essential part of the photosynthetic electron transport chain. A strategy is developed to immobilize and orient PSI complexes on gold electrodes allowing to probe the complex's electron acceptor side, the chlorophyll special pair P700. Electrochemical scanning tunneling microscopy (ECSTM) imaging and current-distance spectroscopy of single protein complex shows lateral size in agreement with its known dimensions, and a PSI apparent height that depends on the probe potential revealing a gating effect in protein conductance. In current-distance spectroscopy, it is observed that the distance-decay constant of the current between PSI and the ECSTM probe depends on the sample and probe electrode potentials. The longest charge exchange distance (lowest distance-decay constant ?) is observed at sample potential 0 mV/SSC (SSC: reference electrode silver/silver chloride) and probe potential 400 mV/SSC. These potentials correspond to hole injection into an electronic state that is available in the absence of illumination. It is proposed that a pair of tryptophan residues located at the interface between P700 and the solution and known to support the hydrophobic recognition of the PSI redox partner plastocyanin, may have an additional role as hole exchange mediator in charge transport through PSI.© 2021 Wiley-VCH GmbH.

JTD Keywords: azurin, current distance decay spectroscopy, cytochrome c(6), electrochemical scanning tunneling microscopy (ecstm), electrochemistry, photosystem i, photosystem-i, plastocyanin, protein electron transfer, recognition, single metalloprotein, single molecules, structural basis, tunneling spectroscopy, 'current, Amino acids, Charge transfer, Chlorine compounds, Current distance decay spectroscopy, Decay spectroscopies, Distance decay, Electrochemical scanning tunneling microscopy, Electrochemical scanning tunneling microscopy (ecstm), Electrodes, Electron transfer, Electron transport properties, Gold compounds, Photosystem i, Photosystems, Protein electron transfer, Protein electron-transfer, Proteins, Scanning tunneling microscopy, Silver halides, Single molecule, Single molecules


Arboleda, A, Amado, L, Rodriguez, J, Naranjo, F, Giraldo, BF, (2021). A new protocol to compare successful versus failed patients using the electromyographic diaphragm signal in extubation process Conference Proceedings : ... Annual International Conference Of The Ieee Engineering In Medicine And Biology Society. Ieee Engineering In Medicine And Biology Society. Conference , 5646-5649

In clinical practice, when a patient is undergoing mechanical ventilation, it is important to identify the optimal moment for extubation, minimizing the risk of failure. However, this prediction remains a challenge in the clinical process. In this work, we propose a new protocol to study the extubation process, including the electromyographic diaphragm signal (diaEMG) recorded through 5-channels with surface electrodes around the diaphragm muscle. First channel corresponds to the electrode on the right. A total of 40 patients in process of withdrawal of mechanical ventilation, undergoing spontaneous breathing tests (SBT), were studied. According to the outcome of the SBT, the patients were classified into two groups: successful (SG: 19 patients) and failure (FG: 21 patients) groups. Parameters extracted from the envelope of each channel of diaEMG in time and frequency domain were studied. After analyzing all channels, the second presented maximum differences when comparing the two groups of patients, with parameters related to root mean square (p = 0.005), moving average (p = 0.001), and upward slope (p = 0.017). The third channel also presented maximum differences in parameters as the time between maximum peak (p = 0.004), and the skewness (p = 0.027). These results suggest that diaphragm EMG signal could contribute to increase the knowledge of the behaviour of respiratory system in these patients and improve the extubation process.Clinical Relevance - This establishes the characterization of success and failure patients in the extubation process. © 2021 IEEE.

JTD Keywords: classification, recognition, Airway extubation, Artificial ventilation, Clinical practices, Clinical process, Diaphragm, Diaphragm muscle, Diaphragms, Electrodes, Electromyographic, Extubation, Frequency domain analysis, Human, Humans, Maximum differences, Mechanical ventilation, New protocol, Respiration, artificial, Respiratory system, Risk of failure, Spontaneous breathing, Surface electrode, Surface emg signals, Thorax, Ventilation, Ventilator weaning


Balakrishnan, H, Fabregas, R, Millan-Solsona, R, Fumagalli, L, Gomila, G, (2021). Spatial Resolution and Capacitive Coupling in the Characterization of Nanowire Nanocomposites by Scanning Dielectric Microscopy Microscopy And Microanalysis 27, 1026-1034

Nanowire-based nanocomposite materials are being developed as transparent and flexible electrodes or as stretchable conductors and dielectrics for biosensing. Here, we theoretically investigate the use of scanning dielectric microscopy (SDM) to characterize these materials in a nondestructive way, with a special focus on the achievable spatial resolution and the possibility of detection of the capacitive coupling between nearby nanowires. Numerical calculations with models involving single and multiple buried nanowires have been performed. We demonstrate that the capacitance gradient spread function of a single buried nanowire consists of a modified Lorenzianan with a cubic decay. We show that the achievable spatial resolution can be determined with good accuracy with the help of this spread function. It is shown that, in general, the spatial resolution worsens when any system parameter decreases the maximum of the nanowire spread function or increases its width, or both. Finally, we show that SDM measurements are also sensitive to the capacitive coupling between nearby nanowires. This latter result is of utmost relevance since the macroscopic electric properties of nanowire nanocomposites largely depend on the electric interaction between nearby nanowires. The present results show that SDM can be a valuable nondestructive subsurface characterization technique for nanowire nanocomposite materials.

JTD Keywords: depth, electrodes, nanocomposites, nanowires, sdm, spatial resolution, subsurface, tomography, Capacitive coupling, Force microscopy, Nanocomposites, Nanowires, Sdm, Spatial resolution, Subsurface


Balakrishnan, H, Millan-Solsona, R, Checa, M, Fabregas, R, Fumagalli, L, Gomila, G, (2021). Depth mapping of metallic nanowire polymer nanocomposites by scanning dielectric microscopy Nanoscale 13, 10116-10126

Polymer nanocomposite materials based on metallic nanowires are widely investigated as transparent and flexible electrodes or as stretchable conductors and dielectrics for biosensing. Here we show that Scanning Dielectric Microscopy (SDM) can map the depth distribution of metallic nanowires within the nanocomposites in a non-destructive way. This is achieved by a quantitative analysis of sub-surface electrostatic force microscopy measurements with finite-element numerical calculations. As an application we determined the three-dimensional spatial distribution of ?50 nm diameter silver nanowires in ?100 nm-250 nm thick gelatin films. The characterization is done both under dry ambient conditions, where gelatin shows a relatively low dielectric constant, ?r ? 5, and under humid ambient conditions, where its dielectric constant increases up to ?r ? 14. The present results show that SDM can be a valuable non-destructive subsurface characterization technique for nanowire-based nanocomposite materials, which can contribute to the optimization of these materials for applications in fields such as wearable electronics, solar cell technologies or printable electronics. © The Royal Society of Chemistry.

JTD Keywords: composite, constant, electrodes, mode, nanostructures, objects, progress, subsurface, tomography, Composite materials, Dielectric materials, Electric force microscopy, Electrostatic force, Force microscopy, Low dielectric constants, Nanocomposites, Numerical calculation, Polymer nanocomposite, Printable electronics, Scanning dielectric microscopy, Silver nanowires, Solar cell technology, Stretchable conductors, Subsurface characterizations, Transparent electrodes, Wearable technology


Covington, JA, Marco, S, Persaud, KC, Schiffman, SS, Nagle, HT, (2021). Artificial Olfaction in the 21st Century Ieee Sensors Journal 21, 12969-12990

The human olfactory system remains one of the most challenging biological systems to replicate. Humans use it without thinking, where it can equally offer protection from harm and bring enjoyment in equal measure. It is the system’s ability to detect and analyze complex odors, without the need for specialized infra-structure, that is the envy of many scientists. The field of artificial olfaction has recruited and stimulated interdisciplinary research and commercial development for several applications that include malodor measurement, medical diagnostics, food and beverage quality, environment and security. Over the last century, innovative engineers and scientists have been focused on solving a range of problems associated with measurement and control of odor. The IEEE Sensors Journal has published Special Issues on olfaction in 2002 and 2012. Here we continue that coverage. In this article, we summarize early work in the 20th Century that served as the foundation upon which we have been building our odor-monitoring instrumental and measurement systems. We then examine the current state of the art that has been achieved over the last two decades as we have transitioned into the 21st Century. Much has been accomplished, but great progress is needed in sensor technology, system design, product manufacture and performance standards. In the final section, we predict levels of performance and ubiquitous applications that will be realized during in the mid to late 21st Century.

JTD Keywords: air-quality, breath analysis, calibration transfer, chemical sensor arrays, chemosensor arrays, drift compensation, electronic nose, gas sensors, headspace sampling, machine learning, machine olfaction, odor detection, plume structure, voc analysis, Artificial olfaction, Electrodes, Electronic nose, Electronic nose technology, Headspace sampling, Instruments, Machine learning, Machine olfaction, Monitoring, Odor detection, Olfactory, Sensor phenomena and characterization, Sensors, Temperature sensors, Voc analysis


Fontana-Escartin, A, Puiggalí-Jou, A, Lanzalaco, S, Bertran, O, Aleman, C, (2021). Manufactured Flexible Electrodes for Dopamine Detection: Integration of Conducting Polymer in 3D-Printed Polylactic Acid Advanced Engineering Materials 23, 2100002

Flexible electrochemical sensors based on electroactive materials have emerged as powerful analytical tools for biomedical applications requiring bioanalytes detection. Within this context, 3D printing is a remarkable technology for developing electrochemical devices, due to no design constraints, waste minimization, and batch manufacturing with high reproducibility. However, the fabrication of 3D printed electrodes is still limited by the in-house fabrication of conductive filaments, which requires the mixture of the electroactive material with melted of thermoplastic polymer (e.g., polylactic acid, PLA). Herein, a simple approach is presented for preparing electrochemical dopamine (DA) biosensors. Specifically, the surface of 3D-printed PLA specimens, which exhibit an elastic modulus and a tensile strength of 3.7 +/- 0.3 GPa and 47 +/- 1 MPa, respectively, is activated applying a 0.5 m NaOH solution for 30 min and, subsequently, poly(3,4-ethylenedioxythiophene) is polymerized in situ using aqueous solvent. The detection of DA with the produced sensors has been demonstrated by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. In summary, the obtained results reflect that low-cost electrochemical sensors, which are widely used in medicine and biotechnology, can be rapidly fabricated using the proposed approach that, although based on additive manufacturing, does not require the preparation of conductive filaments.

JTD Keywords: 3d printers, Additive manufacturing, Amines, Batch manufacturing, Biomedical applications, Chronoamperometry, Conducting polymer, Conducting polymers, Conductive filaments, Conservation, Cyclic voltammetry, Differential pulse voltammetry, Electroactive material, Electrochemical biosensor, Electrochemical devices, Electrochemical sensors, Electrodes, Electron emission, Flexible electrode, High reproducibility, Medical applications, Neurophysiology, Poly-3 ,4-ethylenedioxythiophene, Polyesters, Polylactic aci, Sodium hydroxide, Tensile strength, Thermoplastic polymer


Dulay, S, Rivas, L, Miserere, S, Pla, L, Berdún, S, Parra, J, Eixarch, E, Gratacós, E, Illa, M, Mir, M, Samitier, J, (2021). in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis Talanta 226, 122045

© 2020 Elsevier B.V. Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4–9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications.

JTD Keywords: biocompatibility, blood-flow, clinical monitoring, electrochemical biosensor, electrodes, hypoxia, implantable sensor, in vivo tissue monitoring, ischemia, lactate, ph, ph sensor, rabbits, responses, vitro, Clinical monitoring, Dual signal outputs, Hypoxia, Implantable sensor, In vivo tissue monitoring, Ischemia, Ph sensor


Badiola-Mateos, M, Di Giuseppe, D, Paoli, R, Lopez-Martinez, MJ, Mencattini, A, Samitier, J, Martinelli, E, (2021). A novel multi-frequency trans-endothelial electrical resistance (MTEER) sensor array to monitor blood-brain barrier integrity Sensors And Actuators B-Chemical 334, 129599

© 2021 Elsevier B.V. The blood-brain barrier (BBB) is a dynamic cellular barrier that regulates brain nutrient supply, waste efflux, and paracellular diffusion through specialized junctional complexes. Finding a system to mimic and monitor BBB integrity (i.e., to be able to assess the effect of certain compounds on opening or closing the barrier) is of vital importance in several pathologies. This work aims to overcome some limitations of current barrier integrity measuring techniques thanks to a multi-layer microfluidic platform with integrated electrodes and Multi-frequency Trans-Endothelial Electrical Resistance (MTEER) in synergy with machine learning algorithms. MTEER measurements are performed across the barrier in a range of frequencies up to 10 MHz highlighting the presence of information on different frequency ranges. Results show that the proposed platform can detect barrier formation, opening, and regeneration afterwards, correlating with the results obtained from immunostaining of junctional complexes. This model presents novel techniques for a future biological barrier in-vitro studies that could potentially help on elucidating barrier opening or sealing on treatments with different drugs.

JTD Keywords: blood-brain barrier, cellular barrier integrity monitoring, impedance sensors, machine learning, microelectrodes, mteer, rapid prototyping, Blood-brain barrier, Cellular barrier integrity monitoring, Electrical impedance spectroscopy, Impedance sensors, Machine learning, Microelectrodes, Mteer, Rapid prototyping


Estrada-Petrocelli, L, Torres, A, Sarlabous, L, Rafols-de-Urquia, M, Ye-Lin, Y, Prats-Boluda, G, Jane, R, Garcia-Casado, J, (2021). Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes Ieee Transactions On Biomedical Engineering 68, 1005-1014

© 1964-2012 IEEE. Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (Rins/noise), (4) basal sEMG with ECG (Rins/cardio) and (5) expiratory sEMG without ECG (Rins/exp). Spectral power, Rins/noise and Rins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of Rins/cardio and significantly higher median frequencies were obtained for CREs. Rins/noise and Rins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement.

JTD Keywords: atmospheric measurements, concentric ring electrodes, electrocardiography, electrodes, electromyography, laplacian potential, non-invasive respiratory monitoring, particle measurements, respiratory muscles, surface electromyography, Concentric ring electrodes, Laplacian potential, Muscles, Non-invasive respiratory monitoring, Respiratory muscles, Surface electromyography


Estrada-Petrocelli, L., Jané, R., Torres, A., (2020). Neural respiratory drive estimation in respiratory sEMG with cardiac arrhythmias Engineering in Medicine & Biology Society (EMBC) 42nd Annual International Conference of the IEEE , IEEE (Montreal, Canada) , 2748-2751

Neural respiratory drive as measured by the electromyography allows the study of the imbalance between the load on respiratory muscles and its capacity. Surface respiratory electromyography (sEMG) is a non-invasive tool used for indirectly assessment of NRD. It also provides a way to evaluate the level and pattern of respiratory muscle activation. The prevalence of electrocardiographic activity (ECG) in respiratory sEMG signals hinders its proper evaluation. Moreover, the occurrence of abnormal heartbeats or cardiac arrhythmias in respiratory sEMG measures can make even more challenging the NRD estimation. Respiratory sEMG can be evaluated using the fixed sample entropy (fSampEn), a technique which is less affected by cardiac artefacts. The aim of this work was to investigate the performance of the fSampEn, the root mean square (RMS) and the average rectified value (ARV) on respiratory sEMG signals with supraventricular arrhythmias (SVA) for NRD estimation. fSampEn, ARV and RMS parameters increased as the inspiratory load increased during the test. fSampEn was less influenced by ECG with SVAs for the NRD estimation showing a greater response to respiratory sEMG, reflected with a higher percentage increase with increasing load (228 % total increase, compared to 142 % and 135 % for ARV and RMS, respectively).

JTD Keywords: Electrocardiography, Muscles, Electrodes, Estimation, Band-pass filters, Electromyography, Heart beat


Lakey, A., Ali, Z., Scott, S. M., Chebil, S., Korri-Youssoufi, H., Hunor, S., Ohlander, A., Kuphal, M., Samitier, J., (2019). Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics Biosensors and Bioelectronics 129, 147-154

Deep Vein Thrombosis and pulmonary embolism (DVT/PE) is one of the most common causes of unexpected death for hospital in-patients. D-dimer is used as a biomarker within blood for the diagnosis of DVT/PE. We report a low-cost microfluidic device with a conveniently biofunctionalised interdigitated electrode (IDE) array and a portable impedimetric reader as a point-of-care (POC) device for the detection of D-dimer to aid diagnosis of DVT/PE. The IDE array elements, fabricated on a polyethylenenaphtalate (PEN) substrate, are biofunctionalised in situ after assembly of the microfluidic device by electropolymerisation of a copolymer of polypyrrole to which is immobilised a histidine tag anti-D-Dimer antibody. The most consistent copolymer films were produced using chronopotentiometry with an applied current of 5μA for a period of 50 s using a two-electrode system. The quality of the biofunctionalisation was monitored using optical microscopy, chronopotentiometry curves and impedimetric analysis. Measurement of clinical plasma sample with a D-dimer at concentration of 437 ng/mL with 15 biofunctionalised IDE array electrodes gave a ratiometric percentage of sample reading against the blank with an average value of 124 ± 15 at 95% confidence. We have demonstrated the concept of a low cost disposable microfluidic device with a receptor functionalised on the IDE array for impedimetric detection towards POC diagnostics. Changing the receptor on the IDE array would allow this approach to be used for the direct detection of a wide range of analytes in a low cost manner.

JTD Keywords: Electropolymerisation, Impedimetric sensing, Interdigitated electrodes, Microfluidics, Point-of-care diagnostics


Saborío, M. G., Svelic, P., Casanovas, J., Ruano, G., Pérez-Madrigal, M. M., Franco, L., Torras, J., Estrany, F., Alemán, C., (2019). Hydrogels for flexible and compressible free standing cellulose supercapacitors European Polymer Journal 118, 347-357

Cellulose-based supercapacitors display important advantages in comparison with devices fabricated with other materials, regarding environmental friendliness, flexibility, cost and versatility. Recent progress in the field has been mainly focused on the utilization of cellulose fibres as: structural mechanical reinforcement of electrodes; precursors of electrically active carbon-based materials; or primary electrolytes that act as reservoirs of secondary electrolytes. In this work, a flexible, lightweight, robust, portable and manageable all-carboxymethyl cellulose symmetric supercapacitor has been obtained by assembling two electrodes based on carboxymethyl cellulose hydrogels to a solid electrolytic medium formulated with the same material. Hydrogels, which were made by cross-linking carboxymethyl cellulose paste with citric acid in water, rendered not only effective solid electrolytic media by simply loading NaCl but also electroactive electrodes. For the latter, conducting polymer microparticles, which were loaded into the hydrogel network during the physical cross-linking step, were appropriately connected through the in situ anodic polymerization of a similar conducting polymer in aqueous medium, thus creating conduction paths. The performance of the assembled supercapacitors has been proved by cyclic voltammetry, galvanostatic charge-discharge and electrochemical impedance spectroscopy. This design opens a new window for the green and mass production of flexible cellulose-based supercapacitors.

JTD Keywords: Conducting polymer, Energy storage, Flexible electrodes, In situ polymerization, Wearable electronics


Blanco-Almazán, D., Groenendaal, W., Catthoor, F., Jané, R., (2019). Analysis of time delay between bioimpedance and respiratory volume signals under inspiratory loaded breathing Engineering in Medicine and Biology Society (EMBC) 41st Annual International Conference of the IEEE , IEEE (Berlín, Germany) , 2365-2368

Bioimpedance is known for its linear relation with volume during normal breathing. For that reason, bioimpedance can be used as a noninvasive and comfortable technique for measuring respiration. The goal of this study is to analyze the temporal behavior of bioimpedance measured in four different electrode configurations during inspiratory loaded breathing. We measured four bioimpedance channels and airflow simultaneously in 10 healthy subjects while incremental inspiratory loads were imposed. Inspiratory loading threshold protocols are associated with breathing pattern changes and were used in respiratory mechanics studies. Consequently, this respiratory protocol allowed us to induce breathing pattern changes and evaluate the temporal relationship of bioimpedance with volume. We estimated the temporal delay between bioimpedance and volume respiratory cycles to evaluate the differences in their temporal behavior. The delays were computed as the lag which maximize the cross-correlation of the signals cycle by cycle. Six of the ten subjects showed delays in at least two different inspiratory loads. The delays were dependent on electrode configuration, hence the appearance of the delays between bioimpedance and volume were conditioned to the location and geometry of the electrode configuration. In conclusion, the delays between these signals could provide information about breathing pattern when breathing conditions change.

JTD Keywords: Bioimpedance, Delays, Electrodes, Protocols, Loading, Electrocardiography, Atmospheric measurements


Estrada, L., Sarlabous, L., Lozano-García, M., Jané, R., Torres, A., (2019). Neural offset time evaluation in surface respiratory signals during controlled respiration Engineering in Medicine and Biology Society (EMBC) 41st Annual International Conference of the IEEE , IEEE (Berlín, Germany) , 2344-2347

The electrical activity of the diaphragm measured by surface electromyography (sEMGdi) provides indirect information on neural respiratory drive. Moreover, it allows evaluating the ventilatory pattern from the onset and offset (ntoff) estimation of the neural inspiratory time. sEMGdi amplitude variation was quantified using the fixed sample entropy (fSampEn), a less sensitive method to the interference from cardiac activity. The detection of the ntoff is controversial, since it is located in an intermediate point between the maximum value and the cessation of sEMGdi inspiratory activity, evaluated by the fSampEn. In this work ntoff detection has been analyzed using thresholds between 40% and 100 % of the fSampEn peak. Furthermore, fSampEn was evaluated analyzing the r parameter from 0.05 to 0.6, using a m equal to 1 and a sliding window size equal to 250 ms. The ntoff has been compared to the offset time (toff) obtained from the airflow during a controlled respiratory protocol varying the fractional inspiratory time from 0.54 to 0.18 whilst the respiratory rate was constant at 16 bpm. Results show that the optimal threshold values were between 66.0 % to 77.0 % of the fSampEn peak value. r values between 0.25 to 0.50 were found suitable to be used with the fSampEn.

JTD Keywords: Protocols, Low pass filters, Electrodes, Standards, Band-pass filters, Muscles, Cutoff frequency


Zaffino, R. L., Mir, M., Samitier, J., (2017). Oligonucleotide probes functionalization of nanogap electrodes Electrophoresis , 38, (21), 2712-2720

Nanogap electrodes have attracted a lot of consideration as promising platform for molecular electronic and biomolecules detection. This is mainly for their higher aspect ratio, and because their electrical properties are easily accessed by current-voltage measurements. Nevertheless, application of standard current-voltages measurements used to characterize nanogap response, and/or to modify specific nanogap electrodes properties, represents an issue. Since the strength of electrical fields in nanoscaled devices can reach high values, even at low voltages. Here, we analyzed the effects induced by different methods of surface modification of nanogap electrodes, in test-voltage application, employed for the electrical detection of a desoxyribonucleic acid (DNA) target. Nanogap electrodes were functionalized with two antisymmetric oligo-probes designed to have 20 terminal bases complementary to the edges of the target, which after hybridization bridges the nanogap, closing the electrical circuit. Two methods of functionalization were studied for this purpose; a random self-assembling of a mixture of the two oligo-probes (OPs) used in the platform, and a selective method that controls the position of each OP at selected side of nanogap electrodes. We used for this aim, the electrophoretic effect induced on negatively charged probes by the application of an external direct current voltage. The results obtained with both functionalization methods where characterized and compared in terms of electrode surface covering, calculated by using voltammetry analysis. Moreover, we contrasted the electrical detection of a DNA target in the nanogap platform either in site-selective and in randomly assembled nanogap. According to our results, a denser, although not selective surface functionalization, is advantageous for such kind of applications.

JTD Keywords: Biosensor bioelectronics, DNA electrophoresis, Nanogap electrodes, Self-assembled monolayers, Site-selective deposition


Schulz, S., Legorburu Cladera, B., Giraldo, B., Bolz, M., Bar, K. J., Voss, A., (2017). Neuronal desynchronization as marker of an impaired brain network Engineering in Medicine and Biology Society (EMBC) 39th Annual International Conference of the IEEE , IEEE (Seogwipo, South Korea) , 2251-2254

Synchronization is a central key feature of neural information processing and communication between different brain areas. Disturbance of oscillatory brain rhythms and decreased synchronization have been associated with different disorders including schizophrenia. The aim of this study was to investigate whether synchronization (in relaxed conditions with no stimuli) between different brain areas within the delta, theta, alpha (alpha1, alpha2), beta (beta1, beta2), and gamma bands is altered in patients with a neurological disorder in order to generate significant cortical enhancements. To achieve this, we investigated schizophrenic patients (SZO; N=17, 37.5±10.4 years, 15 males) and compared them to healthy subjects (CON; N=21, 36.7±13.4 years, 15 males) applying the phase locking value (PLV). We found significant differences between SZO and CON in different brain areas of the theta, alpha1, beta2 and gamma bands. These areas are related to the central and parietal lobes for the theta band, the parietal lobe for the alpha1, the parietal and frontal for the beta2 and the frontal-central for the gamma band. The gamma band revealed the most significant differences between CON and SZO. PLV were 61.7% higher on average in SZO in most of the clusters when compared to CON. The related brain areas are directly related to cognition skills which are proved to be impaired in SZO. The results of this study suggest that synchronization in SZO is also altered when the patients were not asked to perform a task that requires their cognitive skills (i.e., no stimuli are applied - in contrast to other findings).

JTD Keywords: Synchronization, Electroencephalography, Electrodes, Brain, Time series analysis, Oscillators, Frequency synchronization


Estrada, L., Torres, A., Sarlabous, L., Jané, R., (2016). Evaluating respiratory muscle activity using a wireless sensor platform Engineering in Medicine and Biology Society (EMBC) 38th Annual International Conference of the IEEE , IEEE (Orlando, USA) , 5769-5772

Wireless sensors are an emerging technology that allows to assist physicians in the monitoring of patients health status. This approach can be used for the non-invasive recording of the electrical respiratory muscle activity of the diaphragm (EMGdi). In this work, we acquired the EMGdi signal of a healthy subject performing an inspiratory load test. To this end, the EMGdi activity was captured from a single channel of electromyography using a wireless platform which was compared with the EMGdi and the inspiratory mouth pressure (Pmouth) recorded with a conventional lab equipment. From the EMGdi signal we were able to evaluate the neural respiratory drive, a biomarker used for assessing the respiratory muscle function. In addition, we evaluated the breathing movement and the cardiac activity, estimating two cardio-respiratory parameters: the respiratory rate and the heart rate. The correlation between the two EMGdi signals and the Pmouth improved with increasing the respiratory load (Pearson's correlation coefficient ranges from 0.33 to 0.85). The neural respiratory drive estimated from both EMGdi signals showed a positive trend with an increase of the inspiratory load and being higher in the conventional EMGdi recording. The respiratory rate comparison between measurements revealed similar values of around 16 breaths per minute. The heart rate comparison showed a root mean error of less than 0.2 beats per minute which increased when incrementing the inspiratory load. In summary, this preliminary work explores the use of wireless devices to record the muscle respiratory activity to derive several physiological parameters. Its use can be an alternative to conventional measuring systems with the advantage of being portable, lightweight, flexible and operating at low energy. This technology can be attractive for medical staff and may have a positive impact in the way healthcare is being delivered.

JTD Keywords: Biomedical monitoring, Electrodes, Medical services, Monitoring, Muscles, Wireless communication, Wireless sensor networks


Estrada, L., Torres, A., Garcia-Casado, J., Sarlabous, L., Prats-Boluda, G., Jané, R., (2016). Time-frequency representations of the sternocleidomastoid muscle electromyographic signal recorded with concentric ring electrodes Engineering in Medicine and Biology Society (EMBC) 38th Annual International Conference of the IEEE , IEEE (Orlando, USA) , 3785-3788

The use of non-invasive methods for the study of respiratory muscle signals can provide clinical information for the evaluation of the respiratory muscle function. The aim of this study was to evaluate time-frequency characteristics of the electrical activity of the sternocleidomastoid muscle recorded superficially by means of concentric ring electrodes (CREs) in a bipolar configuration. The CREs enhance the spatial resolution, attenuate interferences, as the cardiac activity, and also simplify the orientation problem associated to the electrode location. Five healthy subjects underwent a respiratory load test in which an inspiratory load was imposed during the inspiratory phase. During the test, the electromyographic signal of the sternocleidomastoid muscle (EMGsc) and the inspiratory mouth pressure (Pmouth) were acquired. Time-frequency characteristics of the EMGsc signal were analyzed by means of eight time-frequency representations (TFRs): the spectrogram (SPEC), the Morlet scalogram (SCAL), the Wigner-Ville distribution (WVD), the Choi-Williams distribution (CHWD), two generalized exponential distributions (GED1 and GED2), the Born-Jordan distribution (BJD) and the Cone-Kernel distribution (CKD). The instantaneous central frequency of the EMGsc showed an increasing behavior during the inspiratory cycle and with the increase of the inspiratory load. The bilinear TFRs (WVD, CHWD, GEDs and BJD) were less sensitive to cardiac activity interference than classical TFRs (SPEC and SCAL). The GED2 was the TFR that shown the best results for the characterization of the instantaneous central frequency of the EMGsc.

JTD Keywords: Electrodes, Interference, Kernel, Mouth, Muscles, Spectrogram, Time-frequency analysis


Urra, O., Casals, A., Jané, R., (2015). The impact of visual feedback on the motor control of the upper-limb Engineering in Medicine and Biology Society (EMBC) 37th Annual International Conference of the IEEE , IEEE (Milan, Italy) , 3945-3948

Stroke is a leading cause of adult disability with upper-limb hemiparesis being one of the most frequent consequences. Given that stroke only affects the paretic arm's control structure (the set of synergies and activation vectors needed to perform a movement), we propose that the control structure of the non-affected arm can serve as a physiological reference to rehabilitate the paretic arm. However, it is unclear how rehabilitation can effectively tune the control structure of a patient. The use of Visual Feedback (VF) is recommended to boost stroke rehabilitation, as it is able to positively modify neural mechanisms and improve motor performance. Thus, in this study we investigate whether VF can effectively modify the control structure of the upper-limb. We asked six neurologically intact subjects to perform a complete upper-limb rehabilitation routine comprised of 12 movements in absence and presence of VF. Our results indicate that VF significantly increases interlimb similarity both in terms of synergies and activation coefficients. However, the magnitude of improvement depended upon each subject. In general, VF brings the control structure of the nondominant side closer to the control structure of dominant side, suggesting that VF modifies the control structure towards more optimized motor patterns. This is especially interesting because stroke mainly affects the activation coefficients of patients and because it has been shown that the control of the affected side resembles that of the nondominant side. In conclusion, VF may enhance motor performance by effectively tuning the control-structure. Notably, this finding offers new insights to design improved stroke rehabilitation.

JTD Keywords: Bars, Biomedical engineering, Electrodes, Electromyography, Mirrors, Muscles, Visualization


Tahirbegi, I. B., Mir, M., Schostek, S., Schurr, M., Samitier, J., (2014). In vivo ischemia monitoring array for endoscopic surgery Biosensors and Bioelectronics 61, 124-130

An array with all-solid-state, potentiometric, miniaturized sensors for pH and potassium was developed to be introduced into the stomach or other sectors of the digestive tract by means of flexible endoscopy. These sensors perform continuous and simultaneous measurement of extracellular pH and potassium. This detection seeks to sense ischemia in the gastric mucosa inside the stomach, an event indicative of local microvascular perfusion and tissue oxygenation status. Our array is proposed as a medical tool to identify the occurrence of the ischemia after gastrointestinal or gastroesophageal anastomosis. The stability and feasibility of the miniaturized working and reference electrodes integrated in the array were studied under in vitro conditions, and the behavior of the potassium and pH ion-selective membranes were optimized to work under acidic gastric conditions with high concentrations of HCl. The array was tested in vivo in pigs to measure the ischemia produced by clamping the blood flow into the stomach. Our results indicate that ischemic and reperfusion states can be sensed in vivo and that information on tissue damage can be collected by this sensor array. The device described here provides a miniaturized, inexpensive, and mass producible sensor array for detecting local ischemia caused by unfavorable anastomotic perfusion and will thus contribute to preventing anastomotic leakage and failure caused by tissue necrosis.

JTD Keywords: Endoscopy, Surgery, Tissue, Gastric anastomosis, Gastric conditions, Ion selective sensors, Ischemia, pH detection, Reference electrodes, Simultaneous measurement, Tissue oxygenation, Sensors


Mir, M., Lugo, R., Tahirbegi, I. B., Samitier, J., (2014). Miniaturizable ion-selective arrays based on highly stable polymer membranes for biomedical applications Sensors 14, (7), 11844-11854

Poly(vinylchloride) (PVC) is the most common polymer matrix used in the fabrication of ion-selective electrodes (ISEs). However, the surfaces of PVC-based sensors have been reported to show membrane instability. In an attempt to overcome this limitation, here we developed two alternative methods for the preparation of highly stable and robust ion-selective sensors. These platforms are based on the selective electropolymerization of poly(3,4-ethylenedioxythiophene) (PEDOT), where the sulfur atoms contained in the polymer covalently interact with the gold electrode, also permitting controlled selective attachment on a miniaturized electrode in an array format. This platform sensor was improved with the crosslinking of the membrane compounds with poly(ethyleneglycol) diglycidyl ether (PEG), thus also increasing the biocompatibility of the sensor. The resulting ISE membranes showed faster signal stabilization of the sensor response compared with that of the PVC matrix and also better reproducibility and stability, thus making these platforms highly suitable candidates for the manufacture of robust implantable sensors.

JTD Keywords: Biomedicine, Electrochemistry, Endoscope, Implantable device, Ion-selective electrode (ISE) sensor, Ischemia, pH detection, Biocompatibility, Chemical sensors, Electrochemistry, Electrodes, Electropolymerization, Endoscopy, Functional polymers, Implants (surgical), Ion selective electrodes, Medical applications, Polyvinyl chlorides, Stabilization, Biomedical applications, Biomedicine, Implantable devices, Ion selective sensors, Ischemia, Membrane instability, pH detection, Poly(3 ,4 ethylenedioxythiophene) (PEDOT), Ion selective membranes


Tahirbegi, I. B., Alvira, M., Mir, M., Samitier, J., (2014). Simple and fast method for fabrication of endoscopic implantable sensor arrays Sensors 14, (7), 11416-11426

Here we have developed a simple method for the fabrication of disposable implantable all-solid-state ion-selective electrodes (ISE) in an array format without using complex fabrication equipment or clean room facilities. The electrodes were designed in a needle shape instead of planar electrodes for a full contact with the tissue. The needle-shape platform comprises 12 metallic pins which were functionalized with conductive inks and ISE membranes. The modified microelectrodes were characterized with cyclic voltammetry, scanning electron microscope (SEM), and optical interferometry. The surface area and roughness factor of each microelectrode were determined and reproducible values were obtained for all the microelectrodes on the array. In this work, the microelectrodes were modified with membranes for the detection of pH and nitrate ions to prove the reliability of the fabricated sensor array platform adapted to an endoscope.

JTD Keywords: Chemical sensors, Cyclic voltammetry, Electrochemistry, Endoscopy, Fabrication, Implants (surgical), Microelectrodes, Needles, Nitrates, Scanning electron microscopy, Biomedicine, Fabricated sensors, Fabrication equipment, Implantable devices, Implantable sensors, Optical interferometry, Planar electrode, Roughness factor, Ion selective electrodes


Estrada, L., Torres, A., Garcia-Casado, J., Prats-Boluda, G., Yiyao, Ye-Lin, Jané, R., (2014). Evaluation of Laplacian diaphragm electromyographic recording in a dynamic inspiratory maneuver Engineering in Medicine and Biology Society (EMBC) 36th Annual International Conference of the IEEE , IEEE (Chicago, USA) , 2201-2204

The analysis of the electromyographic signal of the diaphragm muscle (EMGdi) can provide important information for evaluating the respiratory muscular function. The EMGdi can be recorded using surface Ag/AgCl disc electrodes in monopolar or bipolar configuration. However, these non-invasive EMGdi recordings are usually contaminated by the electrocardiographic (ECG) signal. EMGdi signal can also be noninvasively recorded using concentric ring electrodes in bipolar configuration (CRE) that estimate Laplacian surface potential. Laplacian recordings increase spatial resolution and attenuate distant bioelectric interferences, such as the ECG. Thus, the objective of this work is to compare and to evaluate CRE and traditional bipolar EMGdi recordings in a healthy subject during a dynamic inspiratory maneuver with incremental inspiratory loads. In the conducted study, it was calculated the cumulative percentage of power spectrum of EMGdi recordings to determine the signal bandwidth, and the power ratio between the EMGdi signal segments with and without cardiac activity. The results of this study suggest that EMGdi acquired with CRE electrodes is less affected by the ECG interference, achieves a wider bandwidth and a higher power ratio between segments without cardiac activity and with cardiac activity.

JTD Keywords: Bandwidth, Electric potential, Electrocardiography, Electrodes, Interference, Laplace equations, Muscles


Gustavsson, J., Ginebra, M. P., Planell, J., Engel, E., (2012). Electrochemical microelectrodes for improved spatial and temporal characterization of aqueous environments around calcium phosphate cements Acta Biomaterialia 8, (1), 386-393

Calcium phosphate compounds can potentially influence cellular fate through ionic substitutions. However, to be able to turn such solution-mediated processes into successful directors of cellular response, a perfect understanding of the material-induced chemical reactions in situ is required. We therefore report on the application of home-made electrochemical microelectrodes, tested as pH and chloride sensors, for precise spatial and temporal characterization of different aqueous environments around calcium phosphate-based biomaterials prepared from α-tricalcium phosphate using clinically relevant liquid to powder ratios. The small size of the electrodes allowed for online measurements in traditionally inaccessible in vitro environments, such as the immediate material-liquid interface and the interior of curing bone cement. The kinetic data obtained has been compared to theoretical sorption models, confirming that the proposed setup can provide key information for improved understanding of the biochemical environment imposed by chemically reactive biomaterials.

JTD Keywords: Calcium phosphate, Hydroxyapatite, Ion sorption, Iridium oxide, Sensors, Animals, Biocompatible Materials, Bone Cements, Calcium Phosphates, Cells, Cultured, Chlorides, Electrochemical Techniques, Gold, Hydrogen-Ion Concentration, Hydroxyapatites, Iridium, Materials Testing, Microelectrodes, Powders, Silver, Silver Compounds, Water


Kuphal, M., Mills, C.A., Korri-Youssoufi, H., Samitier, J., (2012). Polymer-based technology platform for robust electrochemical sensing using gold microelectrodes Sensors and Actuators B: Chemical 161, (1), 279-284

Rapid and inexpensive development of electrochemical sensors with good exploitation potential may be produced using a polymer as a substrate material. However, fabrication of polymer-based sensors is challenging. Using photolithography and etching of gold-coated poly(ethylene-2,6-naphthalate) (PEN), we have succeeded in fabricating disk-shaped and interdigitated microelectrodes (uEs). The electrodes have an excellent adhesion to the polymer and are encapsulated using a novel room-temperature process, applicable for low-cost, high-throughput fabrication. The PEN surface has been characterized in respect of wettability, surface energy and surface roughness. Finally, the electrodes give stable and reproducible electrochemical impedance spectroscopy and cyclic voltammetry responses, using the redox couple ferrocyanide and ruthenium hexamine. The results demonstrate the robustness and functionality of the polymer-based sensor platform with minimum feature sizes of 6 um.

JTD Keywords: Poly(ethylene naphthalate), Photolithography, Microelectrodes, Interdigitated electrodes, Electrochemical characterization, Electrochemical sensor


Antelis, J.M., Montesano, L., Giralt, X., Casals, A., Minguez, J., (2012). Detection of movements with attention or distraction to the motor task during robot-assisted passive movements of the upper limb Engineering in Medicine and Biology Society (EMBC) 34th Annual International Conference of the IEEE , IEEE (San Diego, USA) , 6410-6413

Robot-assisted rehabilitation therapies usually focus on physical aspects rather than on cognitive factors. However, cognitive aspects such as attention, motivation, and engagement play a critical role in motor learning and thus influence the long-term success of rehabilitation programs. This paper studies motor-related EEG activity during the execution of robot-assisted passive movements of the upper limb, while participants either: i) focused attention exclusively on the task; or ii) simultaneously performed another task. Six healthy subjects participated in the study and results showed lower desynchronization during passive movements with another task simultaneously being carried out (compared to passive movements with exclusive attention on the task). In addition, it was proved the feasibility to distinguish between the two conditions.

JTD Keywords: Electrodes, Electroencephalography, Induction motors, Medical treatment, Robot sensing systems, Time frequency analysis, Biomechanics, Cognition, Electroencephalography, Medical robotics, Medical signal detection, Medical signal processing, Patient rehabilitation, Attention, Cognitive aspects, Desynchronization, Engagement, Motivation, Motor learning, Motor task, Motor-related EEG activity, Physical aspects, Robot-assisted passive movement detection, Robot-assisted rehabilitation therapies, Upper limb


Artés, Juan M., Díez-Pérez, Ismael, Sanz, Fausto, Gorostiza, Pau, (2011). Direct measurement of electron transfer distance decay constants of single redox proteins by electrochemical tunneling spectroscopy ACS Nano 5, (3), 2060-2066

We present a method to measure directly and at the single-molecule level the distance decay constant that characterizes the rate of electron transfer (ET) in redox proteins. Using an electrochemical tunneling microscope under bipotentiostatic control, we obtained current-distance spectroscopic recordings of individual redox proteins confined within a nanometric tunneling gap at a well-defined molecular orientation. The tunneling current decays exponentially, and the corresponding decay constant (β) strongly supports a two-step tunneling ET mechanism. Statistical analysis of decay constant measurements reveals differences between the reduced and oxidized states that may be relevant to the control of ET rates in enzymes and biological electron transport chains.

JTD Keywords: Long-range electron transfer (LRET), Distance decay constant, Single-molecule electrochemistry, Redox enzyme, Metalloprotein, Blue copper protein, Azurin, Electrochemical scanning tunneling microscopy and spectroscopy, Nanoelectrodes, Debye length, Electrochemical charge screening


Illa, X., Rodriguez-Trujillo, R., Ordeig, O., De Malsche, W., Homs-Corbera, A., Gardeniers, H., Desmet, G., Kutter, J. P., Samitier, J., Romano-Rodríguez, A., (2010). Simultaneous impedance and fluorescence detection of proteins in a cyclo olefin polymer chip containing a column with an ordered pillar array with integrated gold microelectrodes MicroTAS 2010 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences , UoG (Gorningen, The Netherlands) 2, 1280-1282

In this work, we report the detection of proteins by means of simultaneous fluorescence and impedance measurements in a cyclo olefin polymer (COP) chip containing an ordered pillar array column, used for reversed-phase liquid chromatography, with integrated microband gold electrodes at the end of the channel.

JTD Keywords: Cyclo olefin polymer, Gold microelectrodes, Impedance, Pillar array, Protein detection


Colomer-Farrarons, J., Miribel-Catala, P. L., Samitier, J., Arundell, M., Rodriguez, I., (2009). Design of a miniaturized electrochemical instrument for in-situ O/sub 2/ monitoring Sensors and Signal Conditioning VLSI Circuits and Systems IV , SPIE (Desdren, Germany) 7363, 73630A

The authors are working toward the design of a device for the detection of oxygen, following a discrete and an integrated instrumentation implementation. The discrete electronics are also used for preliminary analysis, to confirm the validity of the conception of system, and its set-up would be used in the characterization of the integrated device, waiting for the chip fabrication. This paper presents the design of a small and portable potentiostat integrated with electrodes, which is cheap and miniaturized, which can be applied for on-site measurements for the simultaneous detection of O/sub 2/ and temperature in water systems. As a first approach a discrete PCB has been designed based on commercial discrete electronics and specific oxygen sensors. Dissolved oxygen concentration (DO) is an important index of water quality and the ability to measure the oxygen concentration and temperature at different positions and depths would be an important attribute to environmental analysis. Especially, the objective is that the sensor and the electronics can be integrated in a single encapsulated device able to be submerged in environmental water systems and be able to make multiple measurements. For our proposed application a small and portable device is developed, where electronics and sensors are miniaturized and placed in close proximity to each other. This system would be based on the sensors and electronics, forming one module, and connected to a portable notebook to save and analyze the measurements on-line. The key electronics is defined by the potentiostat amplifier, used to fix the voltage between the working (WE) and reference (RE) electrodes following an input voltage (Vin). Vin is a triangular signal, programmed by a LabView/sup c / interface, which is also used to represent the CV transfers. To obtain a smaller and compact solution the potentiostat amplifier has also been integrated defining a full custom ASIC amplifier, which is in progress, looking for a point-of-care device. These circuits have been designed with a 0.13 mu m technology from ST Microelectronics through the CMP-TIMA service.

JTD Keywords: Amplifiers, Application specific integrated circuits, Chemical sensors, Electrodes, Portable instruments, Temperature measurement, Water sources


Guaus, E., Errachid, A., Torrent-Burgues, J., (2008). Voltammetric response of a glassy carbon electrode modified by a Langmuir-Blodgett film of a thiomacrocyclic compound Journal of Electroanalytical Chemistry , 614, (1-2), 73-82

A Langmuir-Blodgett (LB) film of a thiomacrocyclic (ThM) compound was deposited on the surface of a glassy carbon electrode (GCE) sheet, from a subphase containing Cu(II) ions. The study of the voltammetric response of this modified GCE when the ThM was bonded to Cu2+, showed that the films had the behaviour of confined species of an electrode surface, and that the current density of the voltammograms increased with the number of LB layers deposited. On the other hand, a LB film of the ThM compound was deposited on the surface of a GCE sheet from a subphase of pure water. When the voltammetric response of the GCE-ThM electrode was studied in a Cu2+-SO42- solution, it was found that a membrane model applies to describe the effect of the LB film on the GCE surface.

JTD Keywords: Modified electrodes, Langmuir-Blodgett films, Cyclic voltammetry, Permeation at LB films, Membrane model of a thin film


Errachid, A., Mills, C. A., Pla, M., Lopez, M. J., Villanueva, G., Bausells, J., Crespo, E., Teixidor, F., Samitier, J., (2008). Focused ion beam production of nanoelectrode arrays Materials Science & Engineering C 5th Maghreb/Europe Meeting on Materials and Their Applications for Devices and Physical, Chemical and Biological Sensors (MADICA 2006) (ed. -----), Elsevier Science (Mahdia, Tunisia) 28, (5-6), 777-780

We present a method for the production of nanoelectrodes using focussed ion beam techniques (FIB). The electrodes utilise nanometric holes milled in a silicon nitride based pasivation layer, followed by wet etching of a silicon oxide based pasivation layer, to expose an underlying gold electrode. After functionalisation using a surface assembled monolayer and an electrochemically grown polypyrrole, these gold nanoelectrodes have been tested, via cyclic voltammetry, in the detection of [Fe(CN)(6)](4-/3-) ions. The nanoelectrodes will be used to investigate the electrical properties of nanometric biological specimen.

JTD Keywords: Neutral carrier, Solid contact, Microelectrodes, Immobilization