DONATE

Publications

by Keyword: Sensor

Gul, M, Fontana-Escartín, A, Arnau, M, Sans, J, Lanzalaco, S, Armelin, E, Chiesa, E, Genta, I, Pérez-Madrigal, MM, Alemán, C, (2024). From Dielectric to Electro-Responsive Thermoplastics: An Approach Based on Electro-Thermal Reorientation and Charged Gas Activation Acs Applied Polymer Materials 6, 15070-15081

The transition from insulator to electro-responsive has been successfully achieved by earlier studies for some inorganic materials by applying external stimuli that modify their 3D and/or electronic structures. In the case of insulating polymers, this transition is frequently accomplished by mixing them with other electroactive materials, even though a few physical treatments that induce suitable chemical modifications have also been reported. In this work, a smart approach based on the application of an electro-thermal reorientation process followed by a charged gas activation treatment has been developed for transforming insulating 3D printed polymers into electro-responsive materials. First, the developed procedure has been exhaustively investigated for 3D printed poly(lactic acid) (PLA) and subsequently has been extended to 3D printed polypropylene (PP) and poly(ethylene terephthalate glycol) (PETG) specimens. FTIR and Raman spectroscopies, X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurements confirmed that, while the electro-thermal reorientation mainly promotes the crystallinity of the samples, the charged gas activation oxidizes the C-O bonds at the surface and consequently modifies the surface morphology and wettability. Furthermore, cyclic voltammetry assays demonstrated that treated PLA, PP, and PETG are electro-responsive, even though the electrochemical activity was much higher for oxygen-containing polymers (PLA and PETG) than for the oxygen-free one (PP). Finally, as a proof of concept, treated 3D printed PLA specimens have been used as electrochemical sensors to detect dopamine (DA), an important neurotransmitter, in a concentration interval ranging from 50 to 1000 mu M. The peak associated with the oxidation from DA to dopaminoquinone and the linearity of the calibration plot, which was constructed using the anodic peak current, proved that treated PLA is not only electro-responsive but also able to electrocatalyze the oxidation of DA.

JTD Keywords: 3d printin, Blends, Dopamine, Electrochemical detection, Electrochemical sensors, Electroresponsive polymers, Films, Hydrogels, Pl, Plasma treatment, Release, Thermoelectric treatment, Thermoplastic polymers


Murugan, D, Tintelott, M, Narayanan, MS, Vu, XT, Kurkina, T, Rodriguez-Emmenegger, C, Schwaneberg, U, Dostalek, J, Ingebrandt, S, Pachauri, V, (2024). Recent Advances in Grating Coupled Surface Plasmon Resonance Technology Advanced Optical Materials 12, 2401862

Surface plasmon resonance (SPR) is a key technique in developing sensor platforms for clinical diagnostics, drug discovery, food quality, and environmental monitoring applications. While prism-coupled (Kretschmann) SPR remains a "gold-standard" for laboratory work-flows due to easier fabrication, handling and high through put, other configurations such as grating-coupled SPR (GC-SPR) and wave-guide mode SPR are yet to fulfil their technology potential. This work evaluates the technical aspects influencing the performance of GC-SPR and reviews recent progress in the fabrication of such platforms. In principle, the GC-SPR involves the illumination of the plasmonic metal film with periodic gratings to excite the surface plasmons (SP) via diffraction-based phase matching. The real performance of the GC-SPR is, however, heavily influenced by the topography of the grating structures produced via top-down lithography techniques. This review discusses latest in approaches to achieve consistent plasmonic gratings with uniform features and periodicity over a large scale and explores the choice of plasmon-active and substrate material for enhanced performance. The review also provides insights into the different GC-SPR measurement configurations and highlights on opportunities with their potential applications as biosensors with translational capabilities. A review on recent progress in the realization of grating-coupled and wave-guide mode surface plasmon resonance (SPR) platforms which have seen very limited progress toward diagnostics applications in comparison to Kretchmann configured SPR. Sophisticated topography manipulation during large-area nanofabrication, integration of emerging nanomaterials, and machine learning-based data analytics are expected to overcome concurrent challenges toward clinical adoption of grating-coupled SPR in coming years. image

JTD Keywords: Aluminum, Biosensor, Chemical sensor, Compact, Fabrication methods, Gc-spr, Gold, Lase, Lithography, Nanogratings, Performance, Plasmonics, Sensitivity enhancement, Sp, Spr sensor


Fontana-Escartín, A, Bertran, O, Alemán, C, (2024). Materials engineering in electrochemical biosensors: A review of cost-effective approaches to efficient biodetection Materials Today Communications 41, 111030

Electrochemical sensors are sophisticated devices capable of detecting a wide range of chemical compounds with exceptional sensitivity and efficiency. Their importance is particularly pronounced in biomedical applications, where the rapid and accurate detection of biomolecules such as dopamine (DA), glucose (G), and nicotinamide adenine dinucleotide (NADH) is crucial for early diagnosis and disease management. These biomarkers are key in monitoring and managing conditions like diabetes, Parkinson and Alzheimer diseases, and bacterial infections. This review provides a comprehensive overview of electrochemical biosensors, detailing the methodologies commonly used by researchers and the latest technological advancements that enable more efficient device development. In this regard, the focus is on the impact and trends of various materials utilized in the fabrication of electrochemical biosensors, including conducting polymers, ceramics, and carbon-based materials. By examining the state of the art, we explore how these materials contribute to enhanced performance and reliability. Furthermore, while the development of highly selective and sensitive nanocomposites has been a primary focus in the field, this review also highlights efforts toward creating cost-effective biosensors with rapid prototyping capabilities. Such innovations aim to maintain high efficacy in electrochemical detection while making advanced diagnostics more accessible. In conclusion, this study aims to inform researchers and professionals about the evolving materials landscape in electrochemical biosensing, offering insights into the future directions of this critical technology.

JTD Keywords: Biomolecules, Biosensor, Dopamine, Electroactive materials, Electrochemical sensors, Electrode, Glucose biosensor, Nanoparticles, Nanosheets, Oxidas, Sensor, Temperature, Transition-metal carbides, Uric-acid


Alvira, M, Mondini, A, Puleo, GL, Tahirbegi, IB, Beccai, L, Sadeghi, A, Mazzolai, B, Mir, M, Samitier, J, (2024). Biomimetic Plant-Root-Inspired Robotic Sensor System Biosensors 14, 565

There are many examples in nature in which the ability to detect is combined with decision-making, such as the basic survival instinct of plants and animals to search for food. We can technically translate this innate function via the use of robotics with integrated sensors and artificial intelligence. However, the integration of sensing capabilities into robotics has traditionally been neglected due to the significant associated technical challenges. Inspired by plant-root chemotropism, we present a miniaturized electrochemical array integrated into a robotic tip, embedding a customized micro-potentiometer. The system contains solid-state sensors fitted to the tip of the robotic root to three-dimensionally monitor potassium and pH changes in a moist, soil-like environment, providing an integrated electronic readout. The sensors measure a range of parameters compatible with realistic soil conditions. The sensors' response can trigger the movement of the robotic root with a control algorithm inspired by the behavior of the plant root that determines the optimal path toward root growth, simulating the decision-making process of a plant. This nature-inspired technology may lead, in the future, to the realization of robotic devices with the potential for monitoring and exploring the soil autonomously.

JTD Keywords: Artificial intelligenc, Biomimetic, Chemical sensor, Ion-selective electrode (ise), Nitrate, Ph, Plant roots, Potassiu, Potassium, Robotics, Soil detection, Tropism


Munoz-Galán, H, Marzoa, A, Bertran, O, Barberà, F, Jiménez-Piqué, E, Ahumada, O, Pérez-Madrigal, MM, Alemán, C, (2024). Optomechanical, Computer Simulation, and Nanoindentation Studies on Tunable Click Hydrogels: Microscopic Insights Acs Applied Polymer Materials 6, 12176-12185

The properties of thiol-yne click polyethylene glycol (PEG)-based hydrogels, which can be tuned by controlling the cis and trans stereochemistry through the gelation conditions, have been investigated at the micro- and nanoscale using optomechanics, atomistic molecular dynamics (MD) simulations, and nanoindentation. Optomechanical measurements on thin films and computer MD simulations have shown that the trans hydrogel is less porous than the cis hydrogel, which is in agreement with both the swelling behavior and the pore size determined for macroscopic 3D hydrogel samples. On the other hand, results from optomechanical measurements using both static and dynamic modes, as well as nanoindentation profiles obtained for thin films adhered to glass substrates, reflect that the trans hydrogel is stiffer than the cis one. Overall, despite the few drawbacks of the techniques employed in this work, from a qualitative point of view, the properties of click PEG-based hydrogels at the micro- and nanoscale follow a behavior similar to that found for 3D macroscopic samples. Considering the wide range of mechanical properties of human tissues (e.g., Young's modulus ranges from 0.1 kPa to many tens of MPa) and the extensive use of hydrogels in applications such as tissue regeneration and tissue-specific drug delivery, the availability of a hydrogel with tunable properties opens the door to targeted biomedicine.

JTD Keywords: Algorithm, Elastic modulu, Ewal, Injectable hydrogels, Molecular dynamics, Molecular-dynamics, Nanoindentation, Optomechanical sensors, Polyethylene glycol hydrogels, Surface stress, Thiol-yneclick hydrogels


Granero-Moya, I, Venturini, V, Belthier, G, Groenen, B, Molina-Jordán, M, González-Martín, M, Trepat, X, van Rheenen, J, Andreu, I, Roca-Cusachs, P, (2024). Nucleocytoplasmic transport senses mechanical forces independently of cell density in cell monolayers Journal Of Cell Science 137, jcs262363

Cells sense and respond to mechanical forces through mechanotransduction, which regulates processes in health and disease. In single adhesive cells, mechanotransduction involves the transmission of force from the extracellular matrix to the cell nucleus, where it affects nucleocytoplasmic transport (NCT) and the subsequent nuclear localization of transcriptional regulators, such as YAP (also known as YAP1). However, if and how NCT is mechanosensitive in multicellular systems is unclear. Here, we characterize and use a fluorescent sensor of nucleocytoplasmic transport (Sencyt) and demonstrate that NCT responds to mechanical forces but not cell density in cell monolayers. Using monolayers of both epithelial and mesenchymal phenotype, we show that NCT is altered in response both to osmotic shocks and to the inhibition of cell contractility. Furthermore, NCT correlates with the degree of nuclear deformation measured through nuclear solidity, a shape parameter related to nuclear envelope tension. In contrast, YAP is sensitive to cell density, showing that the YAP response to cell-cell contacts is not via a mere mechanical effect of NCT. Our results demonstrate the generality of the mechanical regulation of NCT.

JTD Keywords: Cell nucleu, Cell nucleus, Deformation, Growth, Induction, Lamin, Mechanobiology, Mechanotransduction, Sensor, Stress, Triggers, Volume, Yap/taz


Colombi, S, Sáez, I, Borras, N, Estrany, F, Pérez-Madrigal, MM, García-Torres, J, Morgado, J, Alemán, C, (2024). Glyoxal crosslinking of electro-responsive alginate-based hydrogels: Effects on the properties Carbohydrate Polymers 337, 122170

To improve the features of alginate-based hydrogels in physiological conditions, Ca2+-crosslinked 2 +-crosslinked semi interpenetrated hydrogels formed by poly(3,4-ethylenedioxythiophene):polystyrene sulfonic acid and alginate (PEDOT/Alg) were subjected to a treatment with glyoxal to form a dual ionic/covalent network. The covalent network density was systematically varied by considering different glyoxalization times (tG). t G ). The content of Ca2+ was significantly higher for the untreated hydrogel than for the glyoxalized ones, while the properties of the hydrogels were found to largely depend on t G . The porosity and swelling capacity decreased with increasing while the stiffness and electrical conductance retention capacity increased with t G . The potentiodynamic response of the hydrogels notably depended on the amount of conformational restraints introduced by the glyoxal, which is a very short crosslinker. Thus, the re-accommodation of the polymer chains during the cyclic potential scans became more difficult with increasing number of covalent crosslinks. This information was used to improve the performance of untreated PEDOT/Alg as electrochemical sensor of hydrogen peroxide by simply applying a tG G of 5 min. Overall, the control of the properties of glyoxalized hydrogels through tG G is very advantageous and can be used as an on-demand strategy to improve the performance of such materials depending on the application.

JTD Keywords: 4-ethylenedioxythiophene), Acid, Behavior, Cell, Conducting hydrogels, Dual networ, Electrochemical biosensor, Fabrication, Gel, Linke, Microspheres, Peroxidase, Poly(3, Polyvinyl-alcohol, Semi-interpenetrated hydrogel


Robbiani, S, Benegiamo, A, Capelli, L, Marco, S, Dellacá, R, (2024). Dielectric excitation of Metal Oxide Semiconductor sensors: an exploratory performances analysis 2024 Ieee International Symposium On Olfaction And Electronic Nose (Isoen)

Metal Oxide Semiconductor (MOX) sensors are among the most widespread devices in chemical sensing, but their use is hindered due to several limitations, including crosssensitivity to temperature and humidity. Few studies suggested that the dielectric excitation readout of MOX sensors can increase the linearity and reduce cross-sensitivity. A bench test on two commercially available MOX sensors was designed and used to evaluate the dielectric excitation readout performances at different concentrations of acetone and ethanol when temperature and humidity were changed. Results show that not only both the real and imaginary parts of the sensors' electrical impedance are strongly frequency dependent, but also the dynamics of the sensors' response. Furthermore, the calculation of cross-sensitivity shows that there are regions of the spectra that allow for a reduction of cross-sensitivity to environmental interferences ranging from 2 to 10 times between 50 and 100 KHz.

JTD Keywords: Confounding factor, Dielectric excitation, Metal oxide semiconductor sensors


Fontana-Escartin, Adrian, El Hauadi, Karima, Perez-Madrigal, Maria M, Lanzalaco, Sonia, Turon, Pau, Aleman, Carlos, (2024). Mechanical and ex-vivo assessment of functionalized surgical sutures for bacterial infection monitoring European Polymer Journal 212, 113050

Surgical sutures are long-established medical devices that play an important role closing and healing damaged tissues and organs postoperatively. However, current commercial sutures are not able to detect infections at the wound site, which are quite frequent after surgery. In this work, we present mechanically stable smart sutures for the real-time monitoring of bacterial growth and biofilm formation. For this purpose, a conducting polymer named poly(3,4-ethylenedioxythiophene) (PEDOT), which is able to detect bacteria metabolites, was implemented as a coating onto commercial biostable sutures. A protecting hydrogel layer with adhesive properties, which was made of polydopamine-polyacrylamide (PDA-PAM), was used to prevent the detachment of the sensing coating of PEDOT upon looping and knotting the suture. The protective hydrogel preserved not only the knot mechanical properties of the suture but also the electrochemical response of the PEDOT-coating and, therefore, its ability to detect NADH from bacteria respiration. Ex-vivo assays using sutured swine intestine samples demonstrated that the suture with the PDA-PAM hydrogel layer detects the growth of bacteria in real tissues. As a proof of concept, sutures coated with PEDOT and protected with PDA-PAM were used to inhibit the local growth of bacteria in sutured intestines by applying controlled electrostimuli. Results evidenced that smart electro-responsive sutures can be used as multi-task devices focused on fighting bacterial infections, meaning not only monitoring but also hampering bacteria growth.

JTD Keywords: 4-ethylenedioxythiophene), Bacteria growth detection, Bacteria growth inhibition, Multi-task biomedical devices, Nanoparticles, Pape, Poly(3, Polydopamine-polyacrylamide, Sensor, Smart suture


Fontana-Escartín, A, Lanzalaco, S, Zhilev, G, Armelin, E, Bertran, O, Alemán, C, (2024). Oxygen plasma treated thermoplastics as integrated electroresponsive sensors Materials Today Communications 38, 107653

Polypropylene (PP), thermoplastic polyurethane (TPU), polyethylene terephthalate glycol (PETG) and polylactic acid (PLA) 3D printed specimens, which are intrinsically non-electroresponsive materials, have been converted into electroresponsive electrodes applying a low-pressure oxygen plasma treatment. After complete chemical, morphological and electrochemical characterization, plasma treated samples have been applied as integrated electrochemical sensors for detecting dopamine and serotonin by cyclic voltammetry and chronoamperometry. Results show differences in the sensing behavior, which have been explained on the basis of the chemical structure of the pristine materials. While plasma treated PLA exhibits the highest performance as electrochemical sensor in terms of sensitivity (lowest limits of detection and quantification) and selectivity (against uric acid and ascorbic acid as interfering substances), plasma treated PP displays the poorest behavior due to its low polarity compared to PLA 3D-printed electrodes. Instead, plasma treated TPU and PETG shows a very good response, much closer to PLA, as sensitive electrodes towards neurotransmitter molecules (dopamine and serotonin). Overall, results open a new door for the fabrication of electrochemical conductive sensors using intrinsically insulating materials, without the need of chemical functionalization processes.

JTD Keywords: 3d printing, Amines, Ascorbic acid, Chemical characterization, Cyclic voltammetry, Dopamine, Electrochemical characterizations, Electrochemical sensor s, Electrochemical sensors, Electrode materials, Electroresponsive materials, Low-pressure oxygen-plasma treatments, Morphological characterization, Multiwalled carbon nanotubes (mwcn), Neurophysiology, Oxygen, Oxygen plasmas, Plastic bottles, Polyethylene terephthalate glycol, Polyethylene terephthalate glycols, Polyethylene terephthalates, Polylact i c acid, Polylactic acid, Polylactic acid pla, Polyols, Polypropylene, Polypropylene oxides, Polypropylenes, Polyurethanes, Reinforced plastics, Supercapacitors, Thermoplast i c polyurethane, Thermoplastic polyurethane, Thermoplastic polyurethanes


Resina, L, Alemán, C, Ferreira, FC, Esteves, T, (2023). Protein-imprinted polymers: How far have "plastic antibodies" come? Biotechnology Advances 68, 108220

Antibodies are highly selective and sensitive, making them the gold standard for recognition affinity tools. However, their production cost is high and their downstream processing is time-consuming. Molecularly imprinted polymers (MIPs) are tailor-made by incorporating specific molecular recognition sites in their structure, thus translating into receptor-like activity mode of action. The interest in molecular imprinting technology, applied to biomacromolecules, has increased in the past decade. MIPs, produced using biomolecules as templates, commonly referred to as "plastic antibodies" or "artificial receptors", have been considered as suitable cheaper and easy to produce alternatives to antibodies. Research on MIPs, designed to recognize proteins or peptides is particularly important, with potential contributions towards biomedical applications, namely biosensors and targeted drug delivery systems. This mini review will cover recent advances on (bio)molecular imprinting technology, where proteins or peptides are targeted or mimicked for sensing and therapeutic applications. Polymerization methods are reviewed elsewhere, being out of the scope of this review. Template selection and immobilization approaches, monomers and applications will be discussed, highlighting possible drawbacks and gaps in research.Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.

JTD Keywords: artificial antibodies, assay, biomimetics, biomolecules, biosensors, delivery, diagnostics, drug delivery, electrochemical detection, nanoparticles, receptors, science-and-technology, selective recognition, selective targeting, separation, templates, Artificial antibodies, Biomimetics, Biomolecules, Biosensors, Diagnostics, Drug delivery, Molecularly imprinted polymers, Nanoparticles, Selective targeting, Solid-phase synthesis


García-Torres, J, Lázaro, C, Sylla, D, Lanzalaco, S, Ginebra, MP, Alemán, C, (2023). Combining 2D organic and 1D inorganic nanoblocks to develop free-standing hybrid nanomembranes for conformable biosensors Journal Of Nanostructure In Chemistry 13, 507-517

We report a simple approach to fabricate free-standing perforated 2D nanomembranes hosting well-ordered 1D metallic nanostructures to obtain hybrid materials with nanostructured surfaces for flexible electronics. Nanomembranes are formed by alternatively depositing perforated poly(lactic acid) (PLA) and poly(3,4-ethylenedioxythiophene) layers. Copper metallic nanowires (NWs) were incorporated into the nanoperforations of the top PLA layer by electrodeposition and further coated with silver via a transmetallation reaction. The combination of 2D polymeric nanomembranes and aligned 1D metallic NWs allows merging the flexibility and conformability of the ultrathin soft polymeric nanomembranes with the good electrical properties of metals for biointegrated electronic devices. Thus, we were able to tailor the nanomembrane surface chemistry as it was corroborated by SEM, EDX, XPS, CV, EIS and contact angle. The obtained hybrid nanomembranes were flexible and conformable showing sensing capacity towards H2O2 with good linear concentration range (0.35–10 mM), sensitivity (120 µA cm?2 mM?1) and limit of detection (7 ?m). Moreover, the membranes showed good stability, reproducibility and selectivity towards H2O2.

JTD Keywords: biointegrated sensors, designs, electronics, fabrication, free-standing films, h2o2, metallic nanowires, nanoparticles, nanowires, sensor, skin, Hydrogen-peroxide, Perforated nanomembranes


Fontana-Escartín, A, Lanzalaco, S, Bertran, O, Aradilla, D, Alemán, C, (2023). Aqueous alginate/MXene inks for 3D printable biomedical devices Colloids And Surfaces A-Physicochemical And Engineering Aspects 671, 131632

Electrochemically responsive hydrogel networks have been obtained usin g printable inks made of a biopolymer, alginate (Alg), and an inorganic 2D material , MXene (titaniu m carbide, Ti3C2Tx) nanosheets. While MXene offers an electrically conductive pathway for electron transfer and Alg provides an interconnected framework for ion diffusion, the printed nanocomposite results, after gelation, in an extended active interface for redox reactions, being an ideal framework to design and construct flexible devices for biomedical applications. In this work, after characterization, we demonstrate that hydrogels obtained by cross-linking printed Alg /MXene inks exhibit great potential for bioelectronics. More specifically, we prove that flexible Alg/MXene hydrogels act as self-supported electroactive electrodes for the electrochemical detection of bioanalytes, such as dopamine, with a performance similar to that achieved using more sophisticated electrodes, as for example those containing conducting poly-mers and electrocatalytic gold nanoparticles. In addition, Alg/MXene hydrogels have been successfully used to regulate the release of a previously loaded broad spectrum antibiotic (chloramphenicol) by electrical stimulation.

JTD Keywords: 3d-printing, Biomedical application s, Composites, Conducting polymers, Drug release, Electroresponsive hydrogels, Fabrication, Hydrogels, Platform, Sensors, Strategy, Surface, Thin-film, Titanium carbide


Blasi, D, Gonzalez-Pato, N, Rodriguez, XR, Diez-Zabala, I, Srinivasan, SY, Camarero, N, Esquivias, O, Roldán, M, Guasch, J, Laromaine, A, Gorostiza, P, Veciana, J, Ratera, I, (2023). Ratiometric Nanothermometer Based on a Radical Excimer for In Vivo Sensing Small 19, 2207806

Ratiometric fluorescent nanothermometers with near-infrared emission play an important role in in vivo sensing since they can be used as intracellular thermal sensing probes with high spatial resolution and high sensitivity, to investigate cellular functions of interest in diagnosis and therapy, where current approaches are not effective. Herein, the temperature-dependent fluorescence of organic nanoparticles is designed, synthesized, and studied based on the dual emission, generated by monomer and excimer species, of the tris(2,4,6-trichlorophenyl)methyl radical (TTM) doping organic nanoparticles (TTMd-ONPs), made of optically neutral tris(2,4,6-trichlorophenyl)methane (TTM-αH), acting as a matrix. The excimer emission intensity of TTMd-ONPs decreases with increasing temperatures whereas the monomer emission is almost independent and can be used as an internal reference. TTMd-ONPs show a great temperature sensitivity (3.4% K-1 at 328 K) and a wide temperature response at ambient conditions with excellent reversibility and high colloidal stability. In addition, TTMd-ONPs are not cytotoxic and their ratiometric outputs are unaffected by changes in the environment. Individual TTMd-ONPs are able to sense temperature changes at the nano-microscale. In vivo thermometry experiments in Caenorhabditis elegans (C. elegans) worms show that TTMd-ONPs can locally monitor internal body temperature changes with spatio-temporal resolution and high sensitivity, offering multiple applications in the biological nanothermometry field.© 2023 The Authors. Small published by Wiley-VCH GmbH.

JTD Keywords: dual emission, elegans, excimer emission, fluorescence, in vivo sensing, luminescence, nanoparticles, organic radical nanoparticles, ratiometric nanothermometers, sensors, thermometry, trityl radicals, Caenorhabditis elegans, Excimer emission, In vivo sensing, Intracellular ph, Luminescence, Organic radical nanoparticles, Ratiometric nanothermometers, Trityl radicals


Bouras, A, Gutierrez-Galvez, A, Burgués, J, Bouzid, Y, Pardo, A, Guiatni, M, Marco, S, (2023). Concentration map reconstruction for gas source location using nano quadcopters: Metal oxide semiconductor sensor implementation and indoor experiments validation Measurement 213, 112638

Garcia-Torres, J, Colombi, S, Mahamed, I, Sylla, D, Arnau, M, Sans, J, Ginebra, MP, Aleman, C, (2023). Nanocomposite Hydrogels with Temperature Response for Capacitive Energy Storage Acs Applied Energy Materials 6, 4487-4495

Borras, N, Sanchez-Sanz, A, Sans, J, Estrany, F, Perez-Madrigal, MM, Aleman, C, (2023). Flexible electroactive membranes for the electrochemical detection of dopamine European Polymer Journal 187, 111915

In addition of a key catecholamine neurotransmitter, dopamine is is the metabolite predominantly produced by specific types of tumors (e.g. paragangliomas and neuroblastomas), which cannot be diagnosed using conven-tional sensitive tests. Within this context, development of flexible electrochemical sensors to monitor dopamine levels in physiological fluids for the early diagnosis and control of diseases related to abnormal levels of such compound, is necessary. In this work, a flexible self-supported membrane, which acts directly as electrode, has been developed to detect dopamine. The membrane consists of three nanoperforated polylactic acid (PLA) layers, which provide flexibility and mechanical integrity, separated by two layers of an electroactive copolymer, which are obtained by electrochemical copolymerization of 3,4-ethylenedioxythiophene and aniline. The sensitivity and detection limit provided by the electroactive copolymer, which is accessible to dopamine molecules through the nanoperforations of the PLA outer layers, is 1.846 mu A/(cm2.mu M) and 1.7 mu M, respectively, in a urea-rich environments that mimics urine. These values allow us to propose the self-standing flexible electrodes devel-oped in this study for the detection of dopamine in patients affected by paragangliomas and neuroblastomas tumors, which typically present dopamine concentrations between 2 and 7 mu M.

JTD Keywords: 4-ethylenedioxythiophene), Conducting polymer, Electrochemical sensor, Electrodes, Hydrogels, Poly(3, Polyaniline, Polylactic acid, Selective detection, Sensors, Supercapacitors


Fernández-Costa, JM, Ortega, MA, Rodríguez-Comas, J, Lopez-Muñoz, G, Yeste, J, Mangas-Florencio, L, Fernández-González, M, Martin-Lasierra, E, Tejedera-Villafranca, A, Ramon-Azcon, J, (2023). Training-on-a-Chip: A MultiOrgan Device to Study the Effect of Muscle Exercise on Insulin Secretion in Vitro Advanced Materials Technologies 8, 2200873

Escartín, A, El Hauadi, K, Lanzalaco, S, Perez-Madrigal, MM, Armelin, E, Turon, P, Alemán, C, (2023). Preparation and Characterization of Functionalized Surgical Meshes for Early Detection of Bacterial Infections Acs Biomaterials Science & Engineering 9, 1104-1115

Isotactic polypropylene (i-PP) nonabsorbable surgical meshes are modified by incorporating a conducting polymer (CP) layer to detect the adhesion and growth of bacteria by sensing the oxidation of nicotinamide adenine dinucleotide (NADH), a metabolite produced by the respiration reactions of such microorganisms, to NAD+. A three-step process is used for such incorporation: (1) treat pristine meshes with low-pressure O2 plasma; (2) functionalize the surface with CP nanoparticles; and (3) coat with a homogeneous layer of electropolymerized CP using the nanoparticles introduced in (2) as polymerization nuclei. The modified meshes are stable and easy to handle and also show good electrochemical response. The detection by cyclic voltammetry of NADH within the interval of concentrations reported for bacterial cultures is demonstrated for the two modified meshes. Furthermore, Staphylococcus aureus and both biofilm-positive (B+) and biofilm-negative (B-) Escherichia coli cultures are used to prove real-time monitoring of NADH coming from aerobic respiration reactions. The proposed strategy, which offers a simple and innovative process for incorporating a sensor for the electrochemical detection of bacteria metabolism to currently existing surgical meshes, holds considerable promise for the future development of a new generation of smart biomedical devices to fight against post-operative bacterial infections.

JTD Keywords: adhesion, bacteria metabolism, behavior, biocompatibility, conducting polymer, electrochemical sensor, hernia repair, in-vivo, liquid, nadh detection, plasma treatment, prevention, reinforcement, sensor, smart meshes, Bacteria metabolism, Bacterial infections, Conducting polymer, Electrochemical sensor, Humans, Nad, Nadh detection, Nanoparticles, Oxidation-reduction, Plasma treatment, Polymers, Polypropylene mesh, Smart meshes, Surgical mesh


De Lama-Odría, MD, del Valle, LJ, Puiggalí, J, (2023). Lanthanides-Substituted Hydroxyapatite for Biomedical Applications International Journal Of Molecular Sciences 24, 3446

Lately, there has been an increasing demand for materials that could improve tissue regenerative therapies and provide antimicrobial effects. Similarly, there is a growing need to develop or modify biomaterials for the diagnosis and treatment of different pathologies. In this scenario, hydroxyapatite (HAp) appears as a bioceramic with extended functionalities. Nevertheless, there are certain disadvantages related to the mechanical properties and lack of antimicrobial capacity. To circumvent them, the doping of HAp with a variety of cationic ions is emerging as a good alterative due to the different biological roles of each ion. Among many elements, lanthanides are understudied despite their great potential in the biomedical field. For this reason, the present review focuses on the biological benefits of lanthanides and how their incorporation into HAp can alter its morphology and physical properties. A comprehensive section of the applications of lanthanides-substituted HAp nanoparticles (HAp NPs) is presented to unveil the potential biomedical uses of these systems. Finally, the need to study the tolerable and non-toxic percentages of substitution with these elements is highlighted.

JTD Keywords: biolabeling, biomedicine, biosensors, bone regeneration, calcium, cancer treatment, cationic ions, cell imaging, cerium, doped hap, hydroxyapatite, implants, in-vitro bioactivity, lanthanides-substitutions, lanthanidessubstitutions, nanoparticles, radiation synovectomy, sm-153 particulate hydroxyapatite, structural-characterization, theragnostics, theranostic nanoplatforms, Europium-doped hydroxyapatite, Hydroxyapatite, Theragnostics


Lanzalaco, S, Mingot, J, Torras, J, Alemán, C, Armelin, E, (2023). Recent Advances in Poly(N-isopropylacrylamide) Hydrogels and Derivatives as Promising Materials for Biomedical and Engineering Emerging Applications Advanced Engineering Materials 25,

Ugarte-Orozco, MJ, Lopez-Munoz, GA, Antonio-Perez, A, Esquivel-Ortiz, KM, Ramon-Azcon, J, (2023). High-throughput biointerfaces for direct, label-free, and multiplexed metaplasmonic biosensing Current Research In Biotechnology 5, 100119

In recent years, metaplasmonic biosensors have emerged as a novel counterpart of well-established plasmonic biosensors based on thin metallic layers. Metaplasmonic biosensors offer high potential for sensor miniaturiza-tion, extreme sensitivity biosensing, and high multiplexing capabilities with detection methods free of coupling optical elements. These capabilities make metaplasmonic biosensors highly attractive for Point-of-Care and handled/portable devices or novel On-Chip devices; as a result, it has increased the number of prototypes and potential applications that emerged during the last years. One of the main challenges to achieving fully operative devices is the achievement of high-throughput biointerfaces for sensitive and selective biodetection in complex media. Despite the superior surface sensitivity achieved by metaplasmonic sensors compared to conventional plasmonic sensors based on metallic thin films, the main limitations to achieving high-throughput and multiplexed biosensing usually are associated with the sensitivity and selectivity of the bioin-terface and, as a consequence, their application to the direct analysis of real complex samples. This graphical review discusses the potential challenges and capabilities of different biofunctionalization strategies, biorecog-nition elements, and antifouling strategies to achieve scalable and high-throughput metaplasmonic biosensing for Point-of-Care devices and bioengineering applications like Organs-On-Chip.

JTD Keywords: Biointerfaces, Biosensing, Biosensors, Cell culture monitoring, Metaplasmonic, Nanoplasmonic, Organ-on-chip, Point-of-care


Riera, R, Archontakis, E, Cremers, G, de Greef, T, Zijlstra, P, Albertazzi, L, (2023). Precision and Accuracy of Receptor Quantification on Synthetic and Biological Surfaces Using DNA-PAINT Acs Sensors 8, 80-93

Characterization of the number and distribution of biological molecules on 2D surfaces is of foremost importance in biology and biomedicine. Synthetic surfaces bearing recognition motifs are a cornerstone of biosensors, while receptors on the cell surface are critical/vital targets for the treatment of diseases. However, the techniques used to quantify their abundance are qualitative or semi-quantitative and usually lack sensitivity, accuracy, or precision. Detailed herein a simple and versatile workflow based on super-resolution microscopy (DNA-PAINT) was standardized to improve the quantification of the density and distribution of molecules on synthetic substrates and cell membranes. A detailed analysis of accuracy and precision of receptor quantification is presented, based on simulated and experimental data. We demonstrate enhanced accuracy and sensitivity by filtering out non-specific interactions and artifacts. While optimizing the workflow to provide faithful counting over a broad range of receptor densities. We validated the workflow by specifically quantifying the density of docking strands on a synthetic sensor surface and the densities of PD1 and EGF receptors (EGFR) on two cellular models.

JTD Keywords: binding, biosensors, cancer, expression, kinetics, localization microscopy, quantification, receptors, single-molecule, super-resolution microscopy, Biosensors, Dna-paint, Quantification, Receptors, Single-molecule, Super-resolution microscopy, Superresolution microscopy


Badiola-Mateos, M, Osaki, T, Kamm, RD, Samitier, J, (2022). In vitro modelling of human proprioceptive sensory neurons in the neuromuscular system Scientific Reports 12, 21318

Proprioceptive sensory neurons (pSN) are an essential and undervalued part of the neuromuscular circuit. A protocol to differentiate healthy and amyotrophic lateral sclerosis (ALS) human neural stem cells (hNSC) into pSN, and their comparison with the motor neuron (MN) differentiation process from the same hNSC sources, facilitated the development of in vitro co-culture platforms. The obtained pSN spheroids cultured interact with human skeletal myocytes showing the formation of annulospiral wrapping-like structures between TrkC + neurons and a multinucleated muscle fibre, presenting synaptic bouton-like structures in the contact point. The comparative analysis of the genetic profile performed in healthy and sporadic ALS hNSC differentiated to pSN suggested that basal levels of ETV1, critical for motor feedback from pSN, were much lower for ALS samples and that the differences between healthy and ALS samples, suggest the involvement of pSN in ALS pathology development and progression.© 2022. The Author(s).

JTD Keywords: Amyotrophic-lateral-sclerosis,pluripotent stem-cells,peripheral nervous-system,stretch reflex arc,mechanosensory circuit,cellular-localization,molecular-cloning,motor-neurons,muscle,expressio


Fontana-Escartín, A, Lanzalaco, S, Pérez-Madrigal, MM, Bertran, O, Alemán, C, (2022). Electrochemical activation for sensing of three‐dimensional‐printed poly(lactic acid) using low‐pressure plasma Plasma Processes And Polymers 19, e2200101

Joseph, A, Wagner, AM, Garay-Sarmiento, M, Aleksanyan, M, Haraszti, T, Söder, D, Georgiev, VN, Dimova, R, Percec, V, Rodriguez-Emmenegger, C, (2022). Zwitterionic Dendrimersomes: A Closer Xenobiotic Mimic of Cell Membranes Advanced Materials 34, e2206288

Building functional mimics of cell membranes is an important task toward the development of synthetic cells. So far, lipid and amphiphilic block copolymers are the most widely used amphiphiles with the bilayers by the former lacking stability while membranes by the latter are typically characterized by very slow dynamics. Herein, we introduce a new type of Janus dendrimer containing a zwitterionic phosphocholine hydrophilic headgroup (JDPC ) and a 3,5-substituted dihydrobenzoate-based hydrophobic dendron. JDPC self-assembles in water into zwitterionic dendrimersomes (z-DSs) that faithfully recapitulate the cell membrane in thickness, flexibility, and fluidity, while being resilient to harsh conditions and displaying faster pore closing dynamics in the event of membrane rupture. This enables the fabrication of hybrid DSs with components of natural membranes, including pore-forming peptides, structure-directing lipids, and glycans to create raft-like domains or onion vesicles. Moreover, z-DSs can be used to create active synthetic cells with life-like features that mimic vesicle fusion and motility as well as environmental sensing. Despite their fully synthetic nature, z-DSs are minimal cell mimics that can integrate and interact with living matter with the programmability to imitate life-like features and beyond. This article is protected by copyright. All rights reserved.This article is protected by copyright. All rights reserved.

JTD Keywords: biological-membranes, bottom-up synthetic biology, chain, hybrid vesicles, hydroethidine, organization, polymersome, proteins, stability, synthetic cells, thickness, vesicle fusion, vesicle motility, vesicles, zwitterionic dendrimersomes, Biosensor, Biosensors, Bottom-up synthetic biology, Hybrid vesicles, Lipid-bilayers, Synthetic cells, Vesicle fusion, Vesicle motility, Zwitterionic dendrimersomes


Molina, BG, Vasani, RB, Jarvis, KL, Armelin, E, Voelcker, NH, Aleman, C, (2022). Dual pH- and electro-responsive antibiotic-loaded polymeric platforms for effective bacterial detection and elimination Reactive & Functional Polymers 181, 105434

We describe a multi-tasking flexible system that is able to release a wide spectrum antibiotic (levofloxacin, LVX) under electrostimulation and act as a pH sensor for detecting bacterial infections. Combining anodic polymer-ization with plasma polymerization processes we engineered dual pH-and electro-responsive polymeric systems. Particularly, the manufactured devices consisted on a layer of poly(hydroxymethyl-3,4-ethylenedioxythiophene) (PHEDOT) loaded with the LVX antibiotic and coated with a plasma polymer layer of poly(acrylic acid) (PAA). The PHEDOT acted as conductive and electro-responsive agent, while the PAA provided pH responsiveness, changing from a compact globular conformation in acid environments to an expanded open coil conformation in alkaline environments. The assembly between the PHEDOT layer and the PAA coating affected the electro-chemical response of the former, becoming dependent on the pH detected by the latter. The conformational change experienced by the PAA layer as a function of the pH and the redox properties of PHEDOT were leveraged for the electrochemical detection of bacteria growth and for regulating the release of the LVX antibiotic, respectively. The effectiveness of the system as a stimulus-responsive antibiotic carrier and pH sensor was also investigated on strains of Escherichia coli and Streptococcus salivarius.

JTD Keywords: Conducting polymer, Delivery, Drug delivery, Electrostimulation, Levofloxacin, Ph sensor, Plasma, Poly(acrylic acid), Selective detection


Burgués, J, Doñate, S, Esclapez, MD, Saúco, L, Marco, S, (2022). Characterization of odour emissions in a wastewater treatment plant using a drone-based chemical sensor system Science Of The Total Environment 846, 157290

Conventionally, odours emitted by different sources present in wastewater treatment plants (WWTPs) are measured by dynamic olfactometry, where a human panel sniffs and analyzes air bags collected from the plant. Although the method is considered the gold standard, the process is costly, slow, and infrequent, which does not allow operators to quickly identify and respond to problems. To better monitor and map WWTP odour emissions, here we propose a small rotary-wing drone equipped with a lightweight (1.3-kg) electronic nose. The "sniffing drone" sucks in air via a ten-meter (33-foot) tube and delivers it to a sensor chamber where it is analyzed in real-time by an array of 21 gas sensors. From the sensor signals, machine learning (ML) algorithms predict the odour concentration that a human panel using the EN13725 methodology would report. To calibrate and validate the predictive models, the drone also carries a remotely controlled sampling device (compliant with EN13725:2022) to collect sample air in bags for post-flight dynamic olfactometry. The feasibility of the proposed system is assessed in a WWTP in Spain through several measurement campaigns covering diverse operating regimes of the plant and meteorological conditions. We demonstrate that training the ML algorithms with dynamic (transient) sensor signals measured in flight conditions leads to better performance than the traditional approach of using steady-state signals measured in the lab via controlled exposures to odour bags. The comparison of the electronic nose predictions with dynamic olfactometry measurements indicates a negligible bias between the two measurement techniques and 95 % limits of agreement within a factor of four. This apparently large disagreement, partly caused by the high uncertainty of olfactometric measurements (typically a factor of two), is more than offset by the immediacy of the predictions and the practical advantages of using a drone-based system.Copyright © 2022. Published by Elsevier B.V.

JTD Keywords: calibration, chemical sensors, drone, dynamic olfactometry, electronic nose, odourquantification, olfaction, volatile organic-compounds, wwtp, Calibration, Chemical sensors, Drone, Dynamic olfactometry, Electronic nose, Environmental monitoring, Odour quantification, Olfaction, Variable selection methods, Wwtp


Riedelová, Z, Pereira, AD, Svoboda, J, Pop-Georgievski, O, Májek, P, Pecánková, K, Dycka, F, Rodriguez-Emmenegger, C, Riedel, T, (2022). The Relation Between Protein Adsorption and Hemocompatibility of Antifouling Polymer Brushes Macromolecular Bioscience 22, 2200247

Whenever an artificial surface comes into contact with blood, proteins are rapidly adsorbed onto its surface. This phenomenon, termed fouling, is then followed by a series of undesired reactions involving activation of complement or the coagulation cascade and adhesion of leukocytes and platelets leading to thrombus formation. Thus, considerable efforts are directed towards the preparation of fouling-resistant surfaces with the best possible hemocompatibility. Herein, a comprehensive hemocompatibility study after heparinized blood contact with seven polymer brushes prepared by surface-initiated atom transfer radical polymerization is reported. The resistance to fouling is quantified and thrombus formation and deposition of blood cellular components on the coatings are analyzed. Moreover, identification of the remaining adsorbed proteins is performed via mass spectroscopy to elucidate their influence on the surface hemocompatibility. Compared with an unmodified glass surface, the grafting of polymer brushes minimizes the adhesion of platelets and leukocytes and prevents the thrombus formation. The fouling from undiluted blood plasma is reduced by up to 99%. Most of the identified proteins are connected with the initial events of foreign body reaction towards biomaterial (coagulation cascade proteins, complement component, and inflammatory proteins). In addition, several proteins that are not previously linked with blood-biomaterial interaction are presented and discussed.

JTD Keywords: antifouling surfaces, biosensor, blood-plasma, coagulation, coatings, compatibility, glycoprotein, hemocompatibility, identification, methacrylate), ms identification, polymer brushes, protein adsorption, surface-chemistry, Antifouling surfaces, High-density-lipoprotein, Protein adsorption


Mughal, S, Lopez-Munoz, GA, Fernandez-Costa, JM, Cortes-Resendiz, A, De Chiara, F, Ramon-Azcon, J, (2022). Organs-on-Chips: Trends and Challenges in Advanced Systems Integration Advanced Materials Interfaces 9,

Organ-on-chip platforms combined with high-throughput sensing technology allow bridging gaps in information presented by 2D cultures modeled on static microphysiological systems. While these platforms do not aim to replicate whole organ systems with all physiological nuances, they try to mimic relevant structural, physiological, and functional features of organoids and tissues to best model disease and/or healthy states. The advent of this platform has not only challenged animal testing but has also presented the opportunity to acquire real-time, high-throughput data about the pathophysiology of disease progression by employing biosensors. Biosensors allow monitoring of the release of relevant biomarkers and metabolites as a result of physicochemical stress. It, therefore, helps conduct quick lead validation to achieve personalized medicine objectives. The organ-on-chip industry is currently embarking on an exponential growth trajectory. Multiple pharmaceutical and biotechnology companies are adopting this technology to enable quick patient-specific data acquisition at substantially low costs.

JTD Keywords: A-chip, Biosensor, Biosensors, Cancer, Cells, Culture, Disease models, Epithelial electrical-resistance, Hydrogel, Microfabrication, Microphysiological systems, Models, Niches, Organ-on-a-chips, Platform


Hutson, TH, Hervera, A, (2022). Editorial: Biochemical and genetic tools to investigate the underlying mechanisms and treatment of sensorimotor pathologies Frontiers In Molecular Neuroscience 15, 1041458

Borras, N, Sanchez-Jimenez, M, Casanovas, J, Aleman, C, Perez-Madrigal, MM, (2022). Porous Poly(3,4-ethylenedioxythiophene)-Based Electrodes for Detecting Stress Biomarkers in Artificial Urine and Sweat Macromolecular Materials And Engineering 307, 2200269

When danger is perceived, the human body responds to overcome obstacles and survive a stressful situation; however, sustained levels of stress are associated with health disorders and diminished life quality. Hence, stress biomarkers are monitored to control stress quantitatively. Herein, a porous sensor (4l-COP/p) composed of poly(3,4-ethylenedioxythiophene) (PEDOT) and poly(3,4-ethylenedioxythiophene-co-N-methylpyrrole) (COP), which is prepared in a four-layered fashion to detect dopamine (DA) and serotonin (5-HT), is presented. Specifically, the detection is conducted in phosphate-buffered saline (PBS), as well as artificial urine and sweat, by applying cyclic voltammetry. The limit of detection values obtained are as low as 5.7 x 10(-6) and 1.4 x 10(-6) m for DA and 5-HT, respectively, when assessed individually in artificial urine. When mixed in PBS, 4l-COP/p detects both biomarkers with a resolution of 0.18 V and a sensitivity of 40 and 30 mu A mm(-1) for DA and 5-HT, respectively. Additionally, by theoretical calculations, the interaction pattern that each stress biomarker establishes with the PEDOT outer layer is elucidated. Whereas DA interacts with the pi-system of PEDOT, 5-HT forms specific hydrogen bonds with the conducting polymer chains. The resolution value obtained depends upon such interactions. Overall, 4l-COP/p electrodes display potential as stress sensing devices for healthcare technologies.

JTD Keywords: Artificial body fluids, Boron-doped diamond, Cortisol, Cyclic voltammetry, Dopamine, Multilayered films, Paper, Saliva, Selective detection, Sensor, Sensors, Serotonin, Serum


Fontana-Escartin, A, Lanzalaco, S, Bertran, O, Aleman, C, (2022). Electrochemical multi-sensors obtained by applying an electric discharge treatment to 3D-printed poly(lactic acid) Applied Surface Science 597, 153623

Electrochemical sensors for real-time detection of several bioanalytes have been prepared by additive manufacturing, shaping non-conductive poly(lactic acid) (PLA) filaments, and applying a physical treatment to create excited species. The latter process, which consists of the application of power discharge of 100 W during 2 min in a chamber at a low pressure of O-2, converts electrochemically inert PLA into an electrochemically responsive material. The electric discharge caused the oxidation of the PLA surface as evidenced by the increment in the quantity of oxygenated species detected by FTIR spectroscopy and X-ray photoelectron spectroscopy (XPS). Indeed, changes in the surface chemical composition became more pronounced with increasing O-2 pressure. After demonstrating the performance of the chemically modified material as individual dopamine and glucose sensors, multiplexed detection has been achieved by measuring simultaneously the two voltammetric signals. This has been performed by collecting the signals in two different regions, a naked chemically modified PLA for dopamine detection and a chemically modified PLA region functionalized with Glucose Oxidase. These outcomes led to define a new paradigm for manufacturing electrodes for electrochemical sensors based on 3D printing without using conducting materials at any stage of the process.

JTD Keywords: Additive manu f a c turing, Carbon, Conductivity, Degradation, Dopamine, Dopamine detection, Glucose detection, Glucose sensors, Immobilization, Multiplexed detect i o n, Oxidase, Plasma treatment


Amil, AF, Ballester, BR, Maier, M, Verschure, PFMJ, (2022). Chronic use of cannabis might impair sensory error processing in the cerebellum through endocannabinoid dysregulation Addictive Behaviors 131, 107297

Chronic use of cannabis leads to both motor deficits and the downregulation of CB1 receptors (CB1R) in the cerebellum. In turn, cerebellar damage is often related to impairments in motor learning and control. Further, a recent motor learning task that measures cerebellar-dependent adaptation has been shown to distinguish well between healthy subjects and chronic cannabis users. Thus, the deteriorating effects of chronic cannabis use in motor performance point to cerebellar adaptation as a key process to explain such deficits. We review the literature relating chronic cannabis use, the endocannabinoid system in the cerebellum, and different forms of cerebellar-dependent motor learning, to suggest that CB1R downregulation leads to a generalized underestimation and misprocessing of the sensory errors driving synaptic updates in the cerebellar cortex. Further, we test our hypothesis with a computational model performing a motor adaptation task and reproduce the behavioral effect of decreased implicit adaptation that appears to be a sign of chronic cannabis use. Finally, we discuss the potential of our hypothesis to explain similar phenomena related to motor impairments following chronic alcohol dependency. © 2022

JTD Keywords: adaptation, addiction, alcohol-abuse, cerebellum, chronic cannabis use, cognition, deficits, endocannabinoid system, error processing, explicit, modulation, motor learning, release, synaptic plasticity, Adaptation, Adaptation, physiological, Alcoholism, Article, Behavioral science, Cannabinoid 1 receptor, Cannabis, Cannabis addiction, Cerebellum, Cerebellum cortex, Cerebellum disease, Chronic cannabis use, Computer model, Down regulation, Endocannabinoid, Endocannabinoid system, Endocannabinoids, Error processing, Hallucinogens, Human, Humans, Motor dysfunction, Motor learning, Nerve cell plasticity, Nonhuman, Physiology, Psychedelic agent, Purkinje-cells, Regulatory mechanism, Sensation, Sensory dysfunction, Sensory error processing impairment, Synaptic transmission, Task performance


Engel, AK, Verschure, PFMJ, Kragic, D, Polani, D, Effenberg, AO, Konig, P, (2022). Editorial: Sensorimotor Foundations of Social Cognition Frontiers In Human Neuroscience 16, 971133-971133

Lopez-Muñoz, GA, Mughal, S, Ramón-Azcón, J, (2022). Sensors and Biosensors in Organs-on-a-Chip Platforms Advances In Experimental Medicine And Biology 1379, 55-80

Biosensors represent a powerful analytical tool for analyzing biomolecular interactions with the potential to achieve real-time quantitative analysis with high accuracy using low sample volumes, minimum sample pretreatment with high potential for the development of in situ and highly integrated monitoring platforms. Considering these advantages, their use in cell-culture systems has increased over the last few years. Between the different technologies for cell culture, organs-on-a-chip (OOCs) represent a novel technology that tries to mimic an organ's functionality by combining tissue engineering/organoid with microfluidics. Although there are still challenges to achieving OOC models with high organ mimicking relevance, these devices can offer effective models for drug treatment development by identifying drug targets, screening toxicity, and determining the potential effects of drugs in living beings. Consequently, in the future, we might replace animal studies by offering more ethical test models. Considering the relevance that different physiological and biochemical parameters have in the correct functionality of cells, sensing and biosensing platforms can offer an effective way for the real-time monitoring of physiological parameters and, in our opinion, more relevant, the secretion of biomarkers such as cytokines, growth factors, and others related with the influence of drugs or other types of stimulus in cell metabolism. Keeping this concept in mind, in this chapter, we focus on describing the potential use of sensors and biosensors in OOC devices to achieve fully integrated platforms that monitor physiological parameters and cell metabolism.© 2022. The Author(s), under exclusive license to Springer Nature Switzerland AG.

JTD Keywords: alignment, biosensors, cell, crystal microbalance biosensor, electrochemical biosensors, future, graphene oxide, label-free detection, organ-on-a-chip, oxygen, pre-clinical platforms, real-time analysis, screening, Biosensors, Organ-on-a-chip, Pre-clinical platforms, Screening, Sensors, Surface-plasmon resonance


Yang, BQ, Wang, YX, Vorobii, M, Sauter, E, Koenig, M, Kumar, R, Rodriguez-Emmenegger, C, Hirtz, M, (2022). Evaluation of Dibenzocyclooctyne and Bicyclononyne Click Reaction on Azido-Functionalized Antifouling Polymer Brushes via Microspotting Advanced Materials Interfaces 9, 2102325

Mir, M, Palma-Florez, S, Lagunas, A, López-Martínez, MJ, Samitier, J, (2022). Biosensors Integration in Blood-Brain Barrier-on-a-Chip: Emerging Platform for Monitoring Neurodegenerative Diseases Acs Sensors 7, 1237-1247

Over the most recent decades, the development of new biological platforms to study disease progression and drug efficacy has been of great interest due to the high increase in the rate of neurodegenerative diseases (NDDs). Therefore, blood-brain barrier (BBB) as an organ-on-a-chip (OoC) platform to mimic brain-barrier performance could offer a deeper understanding of NDDs as well as a very valuable tool for drug permeability testing for new treatments. A very attractive improvement of BBB-oC technology is the integration of detection systems to provide continuous monitoring of biomarkers in real time and a fully automated analysis of drug permeably, rendering more efficient platforms for commercialization. In this Perspective, an overview of the main BBB-oC configurations is introduced and a critical vision of the BBB-oC platforms integrating electronic read out systems is detailed, indicating the strengths and weaknesses of current devices, proposing the great potential for biosensors integration in BBB-oC. In this direction, we name potential biomarkers to monitor the evolution of NDDs related to the BBB and/or drug cytotoxicity using biosensor technology in BBB-oC.

JTD Keywords: biosensors, blood−brain barrier (bbb), neurodegenerative diseases (ndds), organ-on-a-chip (ooc), Bbb, Biosensors, Blood-brain barrier (bbb), Electrical-resistance, Electrochemical biosensors, Endothelial-cells, In-vitro model, Matrix metalloproteinases, Mechanisms, Neurodegenerative diseases (ndds), Organ-on-a-chip (ooc), Permeability, Stress, Transendothelial electrical resistance (teer), Transepithelial, Transepithelial/transendothelial electrical resistance (teer), Transport


Marti, D, Martin-Martinez, E, Torras, J, Betran, O, Turon, P, Aleman, C, (2022). In silico study of substrate chemistry effect on the tethering of engineered antibodies for SARS-CoV-2 detection: Amorphous silica vs gold Colloids And Surfaces B-Biointerfaces 213, 112400

The influence of the properties of different solid substrates on the tethering of two antibodies, IgG1-CR3022 and IgG1-S309, which were specifically engineered for the detection of SARS-CoV-2, has been examined at the molecular level using conventional and accelerated Molecular Dynamics (cMD and aMD, respectively). Two surfaces with very different properties and widely used in immunosensors for diagnosis, amorphous silica and the most stable facet of the face-centered cubic gold structure, have been considered. The effects of such surfaces on the structure and orientation of the immobilized antibodies have been determined by quantifying the tilt and hinge angles that describe the orientation and shape of the antibody, respectively, and the dihedrals that measure the relative position of the antibody arms with respect to the surface. Results show that the interactions with amorphous silica, which are mainly electrostatic due to the charged nature of the surface, help to preserve the orientation and structure of the antibodies, especially of the IgG1-CR3022, indicating that the primary sequence of those antibodies also plays some role. Instead, short-range van der Waals interactions with the inert gold surface cause a higher degree tilting and fraying of the antibodies with respect to amorphous silica. The interactions between the antibodies and the surface also affect the correlation among the different angles and dihedrals, which increases with their strength. Overall, results explain why amorphous silica substrates are frequently used to immobilize antibodies in immunosensors. © 2022 The Authors

JTD Keywords: amorphous silica, antibody immobilization, enzyme, gol d, gold, immobilization, immunosensor, molecu l a r dynamics, molecular dynamics, protein adsorption, sars-cov-2 immunosensor, simulations, spike protein, surface interactions, target, vaccine, Amorphous silica, Antibodies, Antibody engineering, Antibody immobilization, Antibody structure, Article, Chemical detection, Computer model, Controlled study, Dihedral angle, Gold, In-silico, Molecular dynamics, Molecular levels, Molecular-dynamics, Nonhuman, Property, Sars, Sars-cov-2 immunosensor, Severe acute respiratory syndrome coronavirus 2, Silica, Silico studies, Silicon dioxide, Solid substrates, Structure analysis, Substrate chemistry, Substrates, Van der waals forces, Virus detection


Ballester, BR, Winstein, C, Schweighofer, N, (2022). Virtuous and Vicious Cycles of Arm Use and Function Post-stroke Frontiers In Neurology 13, 804211

Large doses of movement practice have been shown to restore upper extremities' motor function in a significant subset of individuals post-stroke. However, such large doses are both difficult to implement in the clinic and highly inefficient. In addition, an important reduction in upper extremity function and use is commonly seen following rehabilitation-induced gains, resulting in “rehabilitation in vain”. For those with mild to moderate sensorimotor impairment, the limited spontaneous use of the more affected limb during activities of daily living has been previously proposed to cause a decline of motor function, initiating a vicious cycle of recovery, in which non-use and poor performance reinforce each other. Here, we review computational, experimental, and clinical studies that support the view that if arm use is raised above an effective threshold, one enters a virtuous cycle in which arm use and function can reinforce each other via self-practice in the wild. If not, one enters a vicious cycle of declining arm use and function. In turn, and in line with best practice therapy recommendations, this virtuous/vicious cycle model advocates for a paradigm shift in neurorehabilitation whereby rehabilitation be embedded in activities of daily living such that self-practice with the aid of wearable technology that reminds and motivates can enhance paretic limb use of those who possess adequate residual sensorimotor capacity. Altogether, this model points to a user-centered approach to recovery post-stroke that is tailored to the participant's level of arm use and designed to motivate and engage in self-practice through progressive success in accomplishing meaningful activities in the wild. Copyright © 2022 Ballester, Winstein and Schweighofer.

JTD Keywords: compensatory movement, computational neurorehabilitation, decision-making, individuals, learned non-use, learned nonuse, monkeys, neurorehabilitation, recovery, rehabilitation, stroke, stroke patients, wearable sensors, wrist, Arm movement, Article, Cerebrovascular accident, Clinical decision making, Clinical practice, Clinical study, Compensatory movement, Computational neurorehabilitation, Computer model, Daily life activity, Decision-making, Experimental study, Human, Induced movement therapy, Learned non-use, Musculoskeletal function, Neurorehabilitation, Paresis, Sensorimotor function, Stroke, Stroke rehabilitation, User-centered design, Vicious cycle, Virtuous cycle, Wearable sensors


Solorzano, A, Eichmann, J, Fernandez, L, Ziems, B, Jimenez-Soto, JM, Marco, S, Fonollosa, J, (2022). Early fire detection based on gas sensor arrays: Multivariate calibration and validation Sensors And Actuators B-Chemical 352, 130961

Smoldering fires are characterized by the production of early gas emissions that can include high levels of CO and Volatile Organic Compounds (VOCs) due to pyrolysis or thermal degradation. Nowadays, standalone CO sensors, smoke detectors, or a combination of these, are standard components for fire alarm systems. While gas sensor arrays together with pattern recognition techniques are a valuable alternative for early fire detection, in practice they have certain drawbacks-they can detect early gas emissions, but can show low immunity to nuisances, and sensor time drift can render calibration models obsolete. In this work, we explore the performance of a gas sensor array for detecting smoldering and plastic fires while ensuring the rejection of a set of nuisances. We conducted variety of fire and nuisance experiments in a validated standard fire room (240 m(3)). Using PLS-DA and SVM, we evaluate the performance of different multivariate calibration models for this dataset. We show that calibration models remain predictive after several months, but perfect performance is not achieved. For example, 4 months after calibration, a PLS-DA model provides 100% specificity and 85% sensitivity since the system has difficulties in detecting plastic fires, whose signatures are close to nuisance scenarios. Nevertheless, our results show that systems based on gas sensor arrays are able to provide faster fire alarm response than conventional smoke-based fire alarms. We also propose the use of small-scale fire experiments to increase the number of calibration conditions at a reduced cost. Our results show that this is an effective way to increase the performance of the model, even when evaluated on a standard fire room. Finally, the acquired datasets are made publicly available to the community (doi: 10.5281/zenodo.5643074).

JTD Keywords: Calibration, Chemical sensors, Co2, Early fire, Early fire detection, En-54, Fire alarm, Fire detection, Fire room, Fires, Gas detectors, Gas emissions, Gas sensors, Pattern recognition, Public dataset, Sensor arrays, Sensors array, Signatures, Smoke, Smoke detector, Smoke detectors, Standard fire, Standard fire room, Support vector machines, Temperature, Toxicity, Volatile organic compounds


Boloix, A, Feiner-Gracia, N, Kober, M, Repetto, J, Pascarella, R, Soriano, A, Masanas, M, Segovia, N, Vargas-Nadal, G, Merlo-Mas, J, Danino, D, Abutbul-Ionita, I, Foradada, L, Roma, J, Cordoba, A, Sala, S, Toledo, JS, Gallego, S, Veciana, J, Albertazzi, L, Segura, MF, Ventosa, N, (2022). Engineering pH-Sensitive Stable Nanovesicles for Delivery of MicroRNA Therapeutics Small 18, 2101959

MicroRNAs (miRNAs) are small non-coding endogenous RNAs, which are attracting a growing interest as therapeutic molecules due to their central role in major diseases. However, the transformation of these biomolecules into drugs is limited due to their unstability in the bloodstream, caused by nucleases abundantly present in the blood, and poor capacity to enter cells. The conjugation of miRNAs to nanoparticles (NPs) could be an effective strategy for their clinical delivery. Herein, the engineering of non-liposomal lipid nanovesicles, named quatsomes (QS), for the delivery of miRNAs and other small RNAs into the cytosol of tumor cells, triggering a tumor-suppressive response is reported. The engineered pH-sensitive nanovesicles have controlled structure (unilamellar), size (<150 nm) and composition. These nanovesicles are colloidal stable (>24 weeks), and are prepared by a green, GMP compliant, and scalable one-step procedure, which are all unavoidable requirements for the arrival to the clinical practice of NP based miRNA therapeutics. Furthermore, QS protect miRNAs from RNAses and when injected intravenously, deliver them into liver, lung, and neuroblastoma xenografts tumors. These stable nanovesicles with tunable pH sensitiveness constitute an attractive platform for the efficient delivery of miRNAs and other small RNAs with therapeutic activity and their exploitation in the clinics.

JTD Keywords: cancer therapy, mirnas delivery, nanocarriers, nanovesicles, neuroblastoma, pediatric cancer, quatsomes, Biodistribution, Cancer therapy, Cell engineering, Cells, Cholesterol, Controlled drug delivery, Diseases, Dna, Dysregulated ph, Lipoplex, Microrna delivery, Mirnas delivery, Nanocarriers, Nanoparticles, Nanovesicle, Nanovesicles, Neuroblastoma, Neuroblastomas, Pediatric cancer, Ph sensitive, Ph sensors, Quatsome, Quatsomes, Rna, Sirna, Sirna delivery, Sirnas delivery, Small interfering rna, Small rna, Targeted drug delivery, Tumors, Vesicles


RIZZELO, L, DE MATTEIS, V, (2022). Identification of SARS-CoV-2 by Gold Nanoparticles Biocell 46, 2369-2380

The SARS-CoV-2 outbreaks highlighted the need for effective, reliable, fast, easy-to-do and cheap diagnostics procedures. We pragmatically experienced that an early positive-case detection, inevitably coupled with a mass vaccination campaign, is a milestone to control the COVID-19 pandemic. Gold nanoparticles (AuNPs) can indeed play a crucial role in this context, as their physicochemical, optics and electronics properties are being extensively used in photothermal therapy (PTT), radiation therapy (RT), drug delivery and diagnostic. AuNPs can be synthesized by several approaches to obtain different sizes and shapes that can be easily functionalized with many kinds of molecules such as antibodies, proteins, probes, and lipids. In addition, AuNPs showed high biocompatibility making them useful tool in medicine field. We thus reviewed here the most relevant evidence on AuNPs as effective way to detect the presence of SARS-CoV-2 antigens. We trust future diagnostic efforts must take this 'old-fashioned' nanotechnology tool into consideration for the development and commercialization of reliable and feasible detection kits.

JTD Keywords: Aggregation, Antibodies, Assay, Covid-19, Diagnosis, Enhanced raman-scattering, Gold nanoparticles, Immunoassay, Pandemic disease, Physicochemical properties, Rapid detection, Sars-cov-2, Sensors, Surface-plasmon resonance, Therapy


Dulay, S, Rivas, L, Pla, L, Berdún, S, Eixarch, E, Gratacós, E, Illa, M, Mir, M, Samitier, J, (2021). Fetal ischemia monitoring with in vivo implanted electrochemical multiparametric microsensors Journal Of Biological Engineering 15, 28

Under intrauterine growth restriction (IUGR), abnormal attainment of the nutrients and oxygen by the fetus restricts the normal evolution of the prenatal causing in many cases high morbidity being one of the top-ten causes of neonatal death. The current gold standards in hospitals to detect this relevant problem is the clinical observation by echography, cardiotocography and Doppler. These qualitative techniques are not conclusive and requires risky invasive fetal scalp blood testing and/or amniocentesis. We developed micro-implantable multiparametric electrochemical sensors for measuring ischemia in real time in fetal tissue and vascular. This implantable technology is designed to continuous monitoring for an early detection of ischemia to avoid potential fetal injury. Two miniaturized electrochemical sensors were developed based on oxygen and pH detection. The sensors were optimized in vitro under controlled concentration, to assess the selectivity and sensitivity required. The sensors were then validated in vivo in the ewe fetus model, by means of their insertion in the muscle leg and inside the iliac artery of the fetus. Ischemia was achieved by gradually obstructing the umbilical cord to regulate the amount of blood reaching the fetus. An important challenge in fetal monitoring is the detection of low levels of oxygen and pH changes under ischemic conditions, requiring high sensitivity sensors. Significant differences were observed in both; pH and pO(2) sensors under changes from normoxia to hypoxia states in the fetus tissue and vascular with both sensors. Herein, we demonstrate the feasibility of the developed sensors for future fetal monitoring in medical applications.

JTD Keywords: electrochemical biosensor, implantable sensor, in vivo validation, ischemia detection, tissue and vascular monitoring, Animal experiment, Animal model, Animal tissue, Article, Blood-gases, Brain, Classification, Controlled study, Diagnosis, Doppler, Early diagnosis, Electrochemical analysis, Electrochemical biosensor, Ewe, Feasibility study, Female, Fetus, Fetus disease, Fetus monitoring, Gestational age, Hypoxemia, Iliac artery, Implantable sensor, In vivo validation, Intrauterine growth restriction, Intrauterine growth retardation, Ischemia detection, Leg muscle, Management, Nonhuman, Oxygen consumption, Ph, Ph and oxygen detection, Ph measurement, Process optimization, Sheep, Tissue and vascular monitoring, Umbilical-cord occlusion


Burgués, J, Esclapez, MD, Doñate, S, Marco, S, (2021). RHINOS: A lightweight portable electronic nose for real-time odor quantification in wastewater treatment plants Iscience 24, 103371

Quantification of odor emissions in wastewater treatment plants (WWTPs) is key to minimize odor impact to surrounding communities. Odor measurements in WWTPs are usually performed via either expensive and discontinuous olfactometry hydrogen sulfide detectors or via fixed electronic noses. We propose a portable lightweight electronic nose specially designed for real-time odor monitoring in WWTPs using small drones. The so-called RHINOS e-nose allows odor measurements with high spatial resolution, and its accuracy is only slightly worse than that of dynamic olfactometry. The device has been calibrated using odor samples collected in a WWTP in Spain over a period of six months and validated in the same WWTP three weeks after calibration. The promising results obtained support the suitability of the proposed instrument to identify the odor sources having the highest emissions, which may give a useful indication to the plant managers as regards odor control and abatement.© 2021 The Author(s).

JTD Keywords: biofiltration, calibration transfer, chemical sensor arrays, chemistry, drift compensation, engineering, environmental chemical engineering, h2s, model, oxide gas sensors, removal, sensor, system, Chemistry, Engineering, Environmental chemical engineering, Sensor, Sensor system, Variable selection methods


Babeli, I, Puiggalí-Jou, A, Roa, JJ, Ginebra, MP, García-Torres, J, Alemán, C, (2021). Hybrid conducting alginate-based hydrogel for hydrogen peroxide detection from enzymatic oxidation of lactate International Journal Of Biological Macromolecules 193, 1237-1248

A conducting nanocomposite hydrogel is developed for the detection of L-lactate. The hydrogel is based on a mixture of alginate (Alg) and poly(3,4-ethylenedioxythiophene) (PEDOT), which is loaded with gold nanoparticles (GNP). In this novel hydrogel, Alg provides 3D structural support and flexibility, PEDOT confers conductivity and sensing capacity, and GNP provides signal amplification with respect to simple voltammetric and chronoamperometric response. The synergistic combination of the properties provided by each component results in a new flexible nanocomposite with outstanding capacity to detect hydrogen peroxide, which has been used to detect the oxidation of L-lactate. The hydrogel detects hydrogen peroxide with linear response and limits of detection of 0.91 ?M and 0.02 ?M by cyclic voltammetry and chronoamperometry, respectively. The hydrogel is functionalized with lactate oxidase, which catalyzes the oxidation of L-lactate to pyruvate, forming hydrogen peroxide. For L-lactate detection, the functionalized biosensor works in two linear regimes, one for concentrations lower than 5 mM with a limit of detection of 0.4 mM, and the other for concentrations up to 100 mM with a limit of detection of 3.5 mM. Because of its linear range interval, the developed biosensor could be suitable for a wide number of biological fluids. © 2021

JTD Keywords: biosensor, dehydrogenase, enzymatic oxidation, films, hardness, indentation, lactate oxidase, Biosensor, Elastic-modulus, Enzymatic oxidation, Lactate, Lactate oxidase, Reacciones enzimáticas


Vila, JC, Castro-Aguirre, N, Lopez-Munoz, GA, Ferret-Minana, A, De Chiara, F, Ramon-Azcon, J, (2021). Disposable Polymeric Nanostructured Plasmonic Biosensors for Cell Culture Adhesion Monitoring Frontiers In Bioengineering And Biotechnology 9, 799325

Over the last years, optical biosensors based on plasmonic nanomaterials have gained great scientific interest due to their unquestionable advantages compared to other biosensing technologies. They can achieve sensitive, direct, and label-free analysis with exceptional potential for multiplexing and miniaturization. Recently, it has been demonstrated the potential of using optical discs as high throughput nanotemplates for the development of plasmonic biosensors in a cost-effective way. This work is a pilot study focused on the development of an integrated plasmonic biosensor for the monitoring of cell adhesion and growth of human retinal pigmented cell line (ARPE-19) under different media conditions (0 and 2% of FBS). We observed an increase of the plasmonic band displacement under 2% FBS compared to 0% conditions over time (1, 3, and 5 h). These preliminary results show that the proposed plasmonic biosensing approach is a direct, non-destructive, and real-time tool that could be employed in the study of living cells behavior and culture conditions. Furthermore, this setup could assess the viability of the cells and their growth over time with low variability between the technical replicates improving the experimental replicability.

JTD Keywords: cell confluency, cell culture, nanocrystals, optical biosensor, Adhesion monitoring, Biosensing, Biosensors, Cell adhesion, Cell confluency, Cell culture, Cells, Condition, Cost effectiveness, Disposables, Nano-structured, Nanocrystals, Optical bio-sensors, Optical biosensor, Plasmonic biosensors, Plasmonic nanostructures, Plasmonics, Polylysine


Lopez-Muñoz, GA, Fernández-Costa, JM, Ortega, MA, Balaguer-Trias, J, Martin-Lasierra, E, Ramón-Azcón, J, (2021). Plasmonic nanocrystals on polycarbonate substrates for direct and label-free biodetection of Interleukin-6 in bioengineered 3D skeletal muscles Nanophotonics 10, 4477-4488

Abstract The development of nanostructured plasmonic biosensors has been widely widespread in the last years, motivated by the potential benefits they can offer in integration, miniaturization, multiplexing opportunities, and enhanced performance label-free biodetection in a wide field of applications. Between them, engineering tissues represent a novel, challenging, and prolific application field for nanostructured plasmonic biosensors considering the previously described benefits and the low levels of secreted biomarkers (?pM–nM) to detect. Here, we present an integrated plasmonic nanocrystals-based biosensor using high throughput nanostructured polycarbonate substrates. Metallic film thickness and incident angle of light for reflectance measurements were optimized to enhance the detection of antibody–antigen biorecognition events using numerical simulations. We achieved an enhancement in biodetection up to 3× as the incident angle of light decreases, which can be related to shorter evanescent decay lengths. We achieved a high reproducibility between channels with a coefficient of variation below 2% in bulk refractive index measurements, demonstrating a high potential for multiplexed sensing. Finally, biosensing potential was demonstrated by the direct and label-free detection of interleukin-6 biomarker in undiluted cell culture media supernatants from bioengineered 3D skeletal muscle tissues stimulated with different concentrations of endotoxins achieving a limit of detection (LOD) of ? 0.03 ng/mL (1.4 pM).

JTD Keywords: assay, crystals, drug, label-free biosensing, molecules, plasmonic nanostructures, sensors, skeletal muscle, tissue engineering, Biodetection, Biomarkers, Biosensors, Cell culture, Cells, Chemical detection, Histology, Interleukin-6, Interleukin6 (il6), Label free, Label-free biosensing, Muscle, Nano-structured, Nanocrystals, Plasmonic nanocrystals, Plasmonic nanostructures, Plasmonics, Polycarbonate substrates, Polycarbonates, Refractive index, Sensitivity, Skeletal muscle, Tissue engineering, Tissues engineerings


Grechuta, K, Costa, JD, Ballester, BR, Verschure, P, (2021). Challenging the Boundaries of the Physical Self: Distal Cues Impact Body Ownership Frontiers In Human Neuroscience 15, 704414

The unique ability to identify one's own body and experience it as one's own is fundamental in goal-oriented behavior and survival. However, the mechanisms underlying the so-called body ownership are yet not fully understood. Evidence based on Rubber Hand Illusion (RHI) paradigms has demonstrated that body ownership is a product of reception and integration of self and externally generated multisensory information, feedforward and feedback processing of sensorimotor signals, and prior knowledge about the body. Crucially, however, these designs commonly involve the processing of proximal modalities while the contribution of distal sensory signals to the experience of ownership remains elusive. Here we propose that, like any robust percept, body ownership depends on the integration and prediction across all sensory modalities, including distal sensory signals pertaining to the environment. To test our hypothesis, we created an embodied goal-oriented Virtual Air Hockey Task, in which participants were to hit a virtual puck into a goal. In two conditions, we manipulated the congruency of distal multisensory cues (auditory and visual) while preserving proximal and action-driven signals entirely predictable. Compared to a fully congruent condition, our results revealed a significant decrease on three dimensions of ownership evaluation when distal signals were incongruent, including the subjective report as well as physiological and kinematic responses to an unexpected threat. Together, these findings support the notion that the way we represent our body is contingent upon all the sensory stimuli, including distal and action-independent signals. The present data extend the current framework of body ownership and may also find applications in rehabilitation scenarios.



JTD Keywords: active perception, body ownership, distal sensory cues, embodied cognition, forward model, Active perception, Adult, Article, Body ownership, Brain, Cortex, Distal sensory cues, Embodied cognition, Feel, Female, Forward model, Hockey, Human, Human experiment, Integration, Male, Models, Neurons, Perception, Peripersonal space, Prediction, Rehabilitation, Rubber hand illusion, Sensory prediction error, Touch


Illa, M, Pla, L, Berdún, S, Mir, M, Rivas, L, Dulay, S, Picard-Hagen, N, Samitier, J, Gratacós, E, Eixarch, E, (2021). Miniaturized electrochemical sensors to monitor fetal hypoxia and acidosis in a pregnant sheep model Biomedicines 9, 1344

Perinatal asphyxia is a major cause of severe brain damage and death. For its prenatal identification, Doppler ultrasound has been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. We have evaluated the performance of a miniaturized multiparametric sensor aiming to evaluate tissular oxygen and pH changes continuously in an umbilical cord occlusion (UCO) sheep model. The electrochemical sensors were inserted in fetal hindlimb skeletal muscle and electrochemical signals were recorded. Fetal hemodynamic changes and metabolic status were also monitored during the experiment. Additionally, histological assessment of the tissue surrounding the sensors was performed. Both electrochemical sensors detected the pO2 and pH changes induced by the UCO and these changes were correlated with hemodynamic parameters as well as with pH and oxygen content in the blood. Finally, histological assessment revealed no signs of alteration on the same day of insertion. This study provides the first evidence showing the application of miniaturized multiparametric electrochemical sensors detecting changes in oxygen and pH in skeletal muscular tissue in a fetal sheep model.

JTD Keywords: continuous monitoring of acid-base status, diagnosis, doppler, electrochemical sensors, growth restriction, high-risk pregnancies, human-fetus, management, responses, tissue ph, Continuous monitoring of acid-base status, Electrochemical sensors, High-risk pregnancies, Umbilical cord occlusion, Umbilical-cord occlusion


Veronika Magdanz, Arnau Llobera, Judith Fuentes, Dalia Mahdy, Islam S. M. Khalil, Maria Guix, Samuel Sanchez, (2021). 3D printed magnet robots for cell delivery with tuned flexibility 25th International Conference On Miniaturized Systems For Chemistry And Life Sciences, µTas 2021 ,

Magnetically actuated microrobots have the potential to make medical operations less invasive, more precise and remotely controlled. Therefore, they are promising for many applications such as targeted therapy or minimally invasive surgeries. Current challenges in the field of magnetic microrobotics include efficient propulsion and biocompatibility. This article addresses both of these aspects and aims to optimize the flexibility of a soft magnetic swimmer by tuning its material properties, define different magnetic segments and investigate its biocompatibility and potential as cell delivery machine.

JTD Keywords: 3d printing, Elastómeros, Sensores remotos


de Oliveira, LF, Braga, SCGN, Augusto, F, Poppi, RJ, (2021). Correlating comprehensive two-dimensional gas chromatography volatile profiles of chocolate with sensory analysis Brazilian Journal Of Analytical Chemistry 8, 131-140

The identification of key components relevant to sensory perception of quality from commercial chocolate samples was accomplished after chemometric processing of GC×GC-MS (Comprehensive Two-dimensional Gas Chromatography with Mass Spectrometric Detection) profiles corresponding to HS-SPME (Headspace Solid Phase Microextraction) extracts of the samples. Descriptive sensory evaluation of samples was carried out using Optimized Descriptive Profile (ODP) procedures, where sensory attributes of 24 commercial chocolate samples were used to classify them in two classes (low and high chocolate flavor). 2D Fisher Ratio analysis was applied to four-way chromatographic data tensors (1st dimension retention time 1tR × 2nd dimension retention time 2tR × m/z × sample), to identify the crucial areas on the chromatograms that resulted on ODP class separation on Principal Component Analysis (PCA) scores plot. Comparing the relevant sections of the chromatograms to the analysis of the corresponding mass spectra, it was possible to assess that most of the information regarding the sample main sensory attributes can be related to only 14 compounds (2,5-dimethylpyrazine, 2,6-dimethyl-4-heptanol, 1-octen-3-ol, trimethylpyrazine, β-pinene, o-cimene, 2-ethyl-3,5-dimethylpyrazine, tetramethylpyrazine, benzaldehyde, 1,3,5-trimethylbenzene, 6-methyl-5-hepten-2-one, limonene, benzeneethanol and 1,1-dimethylbutylbenzene) among the complex blend of volatiles found on these extremely complex samples.

JTD Keywords: classification, cocoa, dark chocolate, feature-selection, fisher ratio, gcxgc-ms, impact, olfactometry, principal component analysis, sensorial analysis, Chocolate flavor, Fisher ratio, Flight mass-spectrometry, Gc×gc-ms, Principal component analysis, Sensorial analysis


Freire, R, Fernandez, L, Mallafré-Muro, C, Martín-Gómez, A, Madrid-Gambin, F, Oliveira, L, Pardo, A, Arce, L, Marco, S, (2021). Full workflows for the analysis of gas chromatography—ion mobility spectrometry in foodomics: Application to the analysis of iberian ham aroma Sensors 21, 6156

Gas chromatography—ion mobility spectrometry (GC-IMS) allows the fast, reliable, and inexpensive chemical composition analysis of volatile mixtures. This sensing technology has been successfully employed in food science to determine food origin, freshness and preventing alimentary fraud. However, GC-IMS data is highly dimensional, complex, and suffers from strong non-linearities, baseline problems, misalignments, peak overlaps, long peak tails, etc., all of which must be corrected to properly extract the relevant features from samples. In this work, a pipeline for signal pre-processing, followed by four different approaches for feature extraction in GC-IMS data, is presented. More precisely, these approaches consist of extracting data features from: (1) the total area of the reactant ion peak chromatogram (RIC); (2) the full RIC response; (3) the unfolded sample matrix; and (4) the ion peak volumes. The resulting pipelines for data processing were applied to a dataset consisting of two different quality class Iberian ham samples, based on their feeding regime. The ability to infer chemical information from samples was tested by comparing the classification results obtained from partial least-squares discriminant analysis (PLS-DA) and the samples’ variable importance for projection (VIP) scores. The choice of a feature extraction strategy is a trade-off between the amount of chemical information that is preserved, and the computational effort required to generate the data models.

JTD Keywords: authenticity, classification, electronic-nose, feature extraction, food analysis, gc-ims, headspace, least-squares, models, pld-da, pre-processing, quality, sensory analysis, wine, Discriminant analysis, Feature extraction, Food analysis, Gas chromatography-mass spectrometry, Gc-ims, Hs-gc-ims, Ion mobility spectrometry, Odorants, Pld-da, Pre-processing, Workflow


Demirel, B, Moulin-Frier, C, Arsiwalla, XD, Verschure, PFMJ, Sánchez-Fibla, M, (2021). Distinguishing Self, Other, and Autonomy From Visual Feedback: A Combined Correlation and Acceleration Transfer Analysis Frontiers In Human Neuroscience 15, 560657

In cognitive science, Theory of Mind (ToM) is the mental faculty of assessing intentions and beliefs of others and requires, in part, to distinguish incoming sensorimotor (SM) signals and, accordingly, attribute these to either the self-model, the model of the other, or one pertaining to the external world, including inanimate objects. To gain an understanding of this mechanism, we perform a computational analysis of SM interactions in a dual-arm robotic setup. Our main contribution is that, under the common fate principle, a correlation analysis of the velocities of visual pivots is shown to be sufficient to characterize the self (including proximo-distal arm-joint dependencies) and to assess motor to sensory influences, and the other by computing clusters in the correlation dependency graph. A correlational analysis, however, is not sufficient to assess the non-symmetric/directed dependencies required to infer autonomy, the ability of entities to move by themselves. We subsequently validate 3 measures that can potentially quantify a metric for autonomy: Granger causality (GC), transfer entropy (TE), as well as a novel “Acceleration Transfer” (AT) measure, which is an instantaneous measure that computes the estimated instantaneous transfer of acceleration between visual features, from which one can compute a directed SM graph. Subsequently, autonomy is characterized by the sink nodes in this directed graph. This study results show that although TE can capture the directional dependencies, a rectified subtraction operation denoted, in this study, as AT is both sufficient and computationally cheaper.

JTD Keywords: agency, attention, autonomy, cognitive development, computational cognition, developmental psychology, sensorimotor learning, Agency, Attention, Autonomy, Cognitive development, Computational cognition, Developmental psychology, Model, Sensorimotor learning, Theory of mind


Hidouri, S, Errachid, AH, Baussels, J, Korpan, YI, Ruiz-Sanchez, O, Baccar, ZM, (2021). Potentiometric sensing of histamine using immobilized enzymes on layered double hydroxides Journal Of Food Science And Technology-Mysore 58, 2936-2942

Diamine oxydase and peroxidase have been co-immobilized onto layered double hydroxide (LDH) thin films for the development of real-time histamine biosensors. The chosen LDH materials are Mg2AlCO3, Mg4FeCl and Ca2AlCl. Prepared bi-enzymatic hybrid nanomaterials are capable of detecting histamine through the electrochemical oxidation of H(2)O(2)and are used as the sensitive membrane for potentiometric microelectrode. Histamine biosensors developed in this work have fast response of less than 20 s, are sensitive and selective, with a large dynamic range of 10(-8)-10(-3) M and a limit of detection of less than 10(-8) M. The detection limit of the developed bi-enzymatic biosensors is relatively higher than those corresponding with gas and liquid chromatography, which are still considered as the reference methods. Finally, the reproducibility, the specificity and the storage stability of the biosensors were studied.

JTD Keywords: Biogenic-amines, Biosensor, Diamine oxidase, Film, Fish, Histamine, Hybrid nanomaterial, Immobilization, Layer double hydroxide, Potentiometric biosensor, Specificity


Molina, BG, Valle, LJ, Casanovas, J, Lanzalaco, S, Pérez-Madrigal, MM, Turon, P, Armelin, E, Alemán, C, (2021). Plasma-Functionalized Isotactic Polypropylene Assembled with Conducting Polymers for Bacterial Quantification by NADH Sensing Advanced Healthcare Materials 10, 2100425

Rapid detection of bacterial presence on implantable medical devices is essential to prevent biofilm formation, which consists of densely packed bacteria colonies able to withstand antibiotic-mediated killing. In this work, a smart approach is presented to integrate electrochemical sensors for detecting bacterial infections in biomedical implants made of isotactic polypropylene (i-PP) using chemical assembly. The electrochemical detection is based on the capacity of conducting polymers (CPs) to detect extracellular nicotinamide adenine dinucleotide (NADH) released from cellular respiration of bacteria, which allows distinguishing prokaryotic from eukaryotic cells. Oxygen plasma-functionalized free-standing i-PP, coated with a layer (≈1.1 µm in thickness) of CP nanoparticles obtained by oxidative polymerization, is used as working electrode for the anodic polymerization of a second CP layer (≈8.2 µm in thickness), which provides very high electrochemical activity and stability. The resulting layered material, i-PP /CP , detects the electro-oxidation of NADH in physiological media with a sensitivity 417 µA cm and a detection limit up to 0.14 × 10 m, which is below the concentration of extracellular NADH found for bacterial cultures of biofilm-positive and biofilm-negative strains. f 2 −2 −3

JTD Keywords: bacteria respiration, bacteria sensors, biomedical implants, flexible sensors, poly(3,4-ethylenedioxythiophene), Bacteria respiration, Bacteria sensors, Biomedical implants, Flexible sensors, Poly(3,4-ethylenedioxythiophene)


Covington, JA, Marco, S, Persaud, KC, Schiffman, SS, Nagle, HT, (2021). Artificial Olfaction in the 21st Century Ieee Sensors Journal 21, 12969-12990

The human olfactory system remains one of the most challenging biological systems to replicate. Humans use it without thinking, where it can equally offer protection from harm and bring enjoyment in equal measure. It is the system’s ability to detect and analyze complex odors, without the need for specialized infra-structure, that is the envy of many scientists. The field of artificial olfaction has recruited and stimulated interdisciplinary research and commercial development for several applications that include malodor measurement, medical diagnostics, food and beverage quality, environment and security. Over the last century, innovative engineers and scientists have been focused on solving a range of problems associated with measurement and control of odor. The IEEE Sensors Journal has published Special Issues on olfaction in 2002 and 2012. Here we continue that coverage. In this article, we summarize early work in the 20th Century that served as the foundation upon which we have been building our odor-monitoring instrumental and measurement systems. We then examine the current state of the art that has been achieved over the last two decades as we have transitioned into the 21st Century. Much has been accomplished, but great progress is needed in sensor technology, system design, product manufacture and performance standards. In the final section, we predict levels of performance and ubiquitous applications that will be realized during in the mid to late 21st Century.

JTD Keywords: air-quality, breath analysis, calibration transfer, chemical sensor arrays, chemosensor arrays, drift compensation, electronic nose, gas sensors, headspace sampling, machine learning, machine olfaction, odor detection, plume structure, voc analysis, Artificial olfaction, Electrodes, Electronic nose, Electronic nose technology, Headspace sampling, Instruments, Machine learning, Machine olfaction, Monitoring, Odor detection, Olfactory, Sensor phenomena and characterization, Sensors, Temperature sensors, Voc analysis


Fontana-Escartin, A, Puiggalí-Jou, A, Lanzalaco, S, Bertran, O, Aleman, C, (2021). Manufactured Flexible Electrodes for Dopamine Detection: Integration of Conducting Polymer in 3D-Printed Polylactic Acid Advanced Engineering Materials 23, 2100002

Flexible electrochemical sensors based on electroactive materials have emerged as powerful analytical tools for biomedical applications requiring bioanalytes detection. Within this context, 3D printing is a remarkable technology for developing electrochemical devices, due to no design constraints, waste minimization, and batch manufacturing with high reproducibility. However, the fabrication of 3D printed electrodes is still limited by the in-house fabrication of conductive filaments, which requires the mixture of the electroactive material with melted of thermoplastic polymer (e.g., polylactic acid, PLA). Herein, a simple approach is presented for preparing electrochemical dopamine (DA) biosensors. Specifically, the surface of 3D-printed PLA specimens, which exhibit an elastic modulus and a tensile strength of 3.7 +/- 0.3 GPa and 47 +/- 1 MPa, respectively, is activated applying a 0.5 m NaOH solution for 30 min and, subsequently, poly(3,4-ethylenedioxythiophene) is polymerized in situ using aqueous solvent. The detection of DA with the produced sensors has been demonstrated by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. In summary, the obtained results reflect that low-cost electrochemical sensors, which are widely used in medicine and biotechnology, can be rapidly fabricated using the proposed approach that, although based on additive manufacturing, does not require the preparation of conductive filaments.

JTD Keywords: 3d printers, Additive manufacturing, Amines, Batch manufacturing, Biomedical applications, Chronoamperometry, Conducting polymer, Conducting polymers, Conductive filaments, Conservation, Cyclic voltammetry, Differential pulse voltammetry, Electroactive material, Electrochemical biosensor, Electrochemical devices, Electrochemical sensors, Electrodes, Electron emission, Flexible electrode, High reproducibility, Medical applications, Neurophysiology, Poly-3 ,4-ethylenedioxythiophene, Polyesters, Polylactic aci, Sodium hydroxide, Tensile strength, Thermoplastic polymer


Dulay, S, Rivas, L, Miserere, S, Pla, L, Berdún, S, Parra, J, Eixarch, E, Gratacós, E, Illa, M, Mir, M, Samitier, J, (2021). in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis Talanta 226, 122045

© 2020 Elsevier B.V. Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4–9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications.

JTD Keywords: biocompatibility, blood-flow, clinical monitoring, electrochemical biosensor, electrodes, hypoxia, implantable sensor, in vivo tissue monitoring, ischemia, lactate, ph, ph sensor, rabbits, responses, vitro, Clinical monitoring, Dual signal outputs, Hypoxia, Implantable sensor, In vivo tissue monitoring, Ischemia, Ph sensor


Badiola-Mateos, M, Di Giuseppe, D, Paoli, R, Lopez-Martinez, MJ, Mencattini, A, Samitier, J, Martinelli, E, (2021). A novel multi-frequency trans-endothelial electrical resistance (MTEER) sensor array to monitor blood-brain barrier integrity Sensors And Actuators B-Chemical 334, 129599

© 2021 Elsevier B.V. The blood-brain barrier (BBB) is a dynamic cellular barrier that regulates brain nutrient supply, waste efflux, and paracellular diffusion through specialized junctional complexes. Finding a system to mimic and monitor BBB integrity (i.e., to be able to assess the effect of certain compounds on opening or closing the barrier) is of vital importance in several pathologies. This work aims to overcome some limitations of current barrier integrity measuring techniques thanks to a multi-layer microfluidic platform with integrated electrodes and Multi-frequency Trans-Endothelial Electrical Resistance (MTEER) in synergy with machine learning algorithms. MTEER measurements are performed across the barrier in a range of frequencies up to 10 MHz highlighting the presence of information on different frequency ranges. Results show that the proposed platform can detect barrier formation, opening, and regeneration afterwards, correlating with the results obtained from immunostaining of junctional complexes. This model presents novel techniques for a future biological barrier in-vitro studies that could potentially help on elucidating barrier opening or sealing on treatments with different drugs.

JTD Keywords: blood-brain barrier, cellular barrier integrity monitoring, impedance sensors, machine learning, microelectrodes, mteer, rapid prototyping, Blood-brain barrier, Cellular barrier integrity monitoring, Electrical impedance spectroscopy, Impedance sensors, Machine learning, Microelectrodes, Mteer, Rapid prototyping


Hirsch, T, Barthel, M, Aarts, P, Chen, YA, Freivogel, S, Johnson, MJ, Jones, TA, Jongsma, MLA, Maier, M, Punt, D, Sterr, A, Wolf, SL, Heise, KF, (2021). A First Step Toward the Operationalization of the Learned Non-Use Phenomenon: A Delphi Study Neurorehabilitation And Neural Repair 35, 383-392

© The Author(s) 2021. Background: The negative discrepancy between residual functional capacity and reduced use of the contralesional hand, frequently observed after a brain lesion, has been termed Learned Non-Use (LNU) and is thought to depend on the interaction of neuronal mechanisms during recovery and learning-dependent mechanisms. Objective: Albeit the LNU phenomenon is generally accepted to exist, currently, no transdisciplinary definition exists. Furthermore, although therapeutic approaches are implemented in clinical practice targeting LNU, no standardized diagnostic routine is described in the available literature. Our objective was to reach consensus regarding a definition as well as synthesize knowledge about the current diagnostic procedures. Methods: We used a structured group communication following the Delphi method among clinical and scientific experts in the field, knowledge from both, the work with patient populations and with animal models. Results: Consensus was reached regarding a transdisciplinary definition of the LNU phenomenon. Furthermore, the mode and strategy of the diagnostic process, as well as the sources of information and outcome parameters relevant for the clinical decision making, were described with a wide range showing the current lack of a consistent universal diagnostic approach. Conclusions: The need for the development of a structured diagnostic procedure and its implementation into clinical practice is emphasized. Moreover, it exists a striking gap between the prevailing hypotheses regarding the mechanisms underlying the LNU phenomenon and the actual evidence. Therefore, basic research is needed to bridge between bedside and bench and eventually improve clinical decision making and further development of interventional strategies beyond the field of stroke rehabilitation.

JTD Keywords: diagnosis, experience-dependent non-use, perceptual disorders, rehabilitation, sensorimotor learning, Diagnosis, Experience-dependent non-use, Perceptual disorders, Rehabilitation, Sensorimotor learning


Ortega, MA, Rodríguez-Comas, J, Velasco-Mallorquí, F, Balaguer-Trias, J, Parra, V, Ramón-Azcón, J, Yavas, O, Quidant, R, Novials, A, Servitja, JM, (2021). In Situ LSPR Sensing of Secreted Insulin in Organ-on-Chip Biosensors 11, 138

Organ-on-a-chip (OOC) devices offer new approaches for metabolic disease modeling and drug discovery by providing biologically relevant models of tissues and organs in vitro with a high degree of control over experimental variables for high-content screening applications. Yet, to fully exploit the potential of these platforms, there is a need to interface them with integrated non-labeled sensing modules, capable of monitoring, in situ, their biochemical response to external stimuli, such as stress or drugs. In order to meet this need, we aim here to develop an integrated technology based on coupling a localized surface plasmon resonance (LSPR) sensing module to an OOC device to monitor the insulin in situ secretion in pancreatic islets, a key physiological event that is usually perturbed in metabolic diseases such as type 2 diabetes (T2D). As a proof of concept, we developed a biomimetic islet-on-a-chip (IOC) device composed of mouse pancreatic islets hosted in a cellulose-based scaffold as a novel approach. The IOC was interfaced with a state-of-the-art on-chip LSPR sensing platform to monitor the in situ insulin secretion. The developed platform offers a powerful tool to enable the in situ response study of microtissues to external stimuli for applications such as a drug-screening platform for human models, bypassing animal testing.

JTD Keywords: biosensor, cytoarchitecture, dna hybridization, gelatin, in situ insulin monitoring, langerhans, lspr sensors, microfluidic device, organ-on-a-chip, parallel, platform, scaffold, Animals, Biosensing techniques, Diabetes mellitus, type 2, Drug discovery, Drug evaluation, preclinical, Human pancreatic-islets, Humans, In situ insulin monitoring, Insulin secretion, Insulins, Lab-on-a-chip devices, Lspr sensors, Oligonucleotide array sequence analysis, Organ-on-a-chip, Surface plasmon resonance


Burgués, J, Esclapez, MD, Doñate, S, Pastor, L, Marco, S, (2021). Aerial mapping of odorous gases in a wastewater treatment plant using a small drone Remote Sensing 13, 1757

Wastewater treatment plants (WWTPs) are sources of greenhouse gases, hazardous air pollutants and offensive odors. These emissions can have negative repercussions in and around the plant, degrading the quality of life of surrounding neighborhoods, damaging the environment, and reducing employee’s overall job satisfaction. Current monitoring methodologies based on fixed gas detectors and sporadic olfactometric measurements (human panels) do not allow for an accurate spatial representation of such emissions. In this paper we use a small drone equipped with an array of electrochemical and metal oxide (MOX) sensors for mapping odorous gases in a mid-sized WWTP. An innovative sampling system based on two (10 m long) flexible tubes hanging from the drone allowed near-source sampling from a safe distance with negligible influence from the downwash of the drone’s propellers. The proposed platform is very convenient for monitoring hard-toreach emission sources, such as the plant’s deodorization chimney, which turned out to be responsible for the strongest odor emissions. The geo-localized measurements visualized in the form of a two-dimensional (2D) gas concentration map revealed the main emission hotspots where abatement solutions were needed. A principal component analysis (PCA) of the multivariate sensor signals suggests that the proposed system can also be used to trace which emission source is responsible for a certain measurement.

JTD Keywords: air pollution, environmental monitoring, gas sensors, industrial emissions, mapping, odour, uav, Air pollution, Drone, Environmental monitoring, Gas sensors, Industrial emissions, Mapping, Odour, Sensors, Uav


Enshaei, H, Puiggalí-Jou, A, del Valle, LJ, Turon, P, Saperas, N, Alemán, C, (2021). Nanotheranostic Interface Based on Antibiotic-Loaded Conducting Polymer Nanoparticles for Real-Time Monitoring of Bacterial Growth Inhibition Advanced Healthcare Materials 10, 2001636

© 2020 Wiley-VCH GmbH Conducting polymers have been increasingly used as biologically interfacing electrodes for biomedical applications due to their excellent and fast electrochemical response, reversible doping–dedoping characteristics, high stability, easy processability, and biocompatibility. These advantageous properties can be used for the rapid detection and eradication of infections associated to bacterial growth since these are a tremendous burden for individual patients as well as the global healthcare system. Herein, a smart nanotheranostic electroresponsive platform, which consists of chloramphenicol (CAM)-loaded in poly(3,4-ethylendioxythiophene) nanoparticles (PEDOT/CAM NPs) for concurrent release of the antibiotic and real-time monitoring of bacterial growth is presented. PEDOT/CAM NPs, with an antibiotic loading content of 11.9 ± 1.3% w/w, are proved to inhibit the growth of Escherichia coli and Streptococcus sanguinis due to the antibiotic release by cyclic voltammetry. Furthermore, in situ monitoring of bacterial activity is achieved through the electrochemical detection of β-nicotinamide adenine dinucleotide, a redox active specie produced by the microbial metabolism that diffuse to the extracellular medium. According to these results, the proposed nanotheranostic platform has great potential for real-time monitoring of the response of bacteria to the released antibiotic, contributing to the evolution of the personalized medicine.

JTD Keywords: bacterial detection, chloramphenicol, conducting polymers, drug, drug release, electrochemical sensors, electrochemistry, electrostimulated release, mechanism, peptide, polythiophene, sensor, sulfonate, Bacterial detection, Chloramphenicol, Conducting polymers, Controlled-release, Drug release, Electrochemical sensors, Electrostimulated release, Polythiophene


López-Ortiz, M, Zamora, RA, Antinori, ME, Gorostiza, P, Remesh, V, van Hulst, NF, Hu, C, Croce, R, (2021). Fast Photo-Chrono-Amperometry of Photosynthetic Complexes for Biosensors and Electron Transport Studies Acs Sensors 6, 581-587

© 2021 American Chemical Society. Photosynthetic reactions in plants, algae, and cyanobacteria are driven by photosystem I and photosystem II complexes, which specifically reduce or oxidize partner redox biomolecules. Photosynthetic complexes can also bind synthetic organic molecules, which inhibit their photoactivity and can be used both to study the electron transport chain and as herbicides and algicides. Thus, their development, characterization, and sensing bears fundamental and applied interest. Substantial efforts have been devoted to developing photosensors based on photosystem II to detect compounds that bind to the plastoquinone sites of this complex. In comparison, photosystem I based sensors have received less attention and could be used to identify novel substances displaying phytotoxic effects, including those obtained from natural product extracts. We have developed a robust procedure to functionalize gold electrodes with photo- and redox-active photosystem I complexes based on transparent gold and a thiolate self-assembled monolayer, and we have obtained reproducible electrochemical photoresponses. Chronoamperometric recordings have allowed us to measure photocurrents in the presence of the viologen derivative paraquat at concentrations below 100 nM under lock-in operation and a sensor dynamic range spanning six orders of magnitude up to 100 mM. We have modeled their time course to identify the main electrochemical processes and limiting steps in the electron transport chain. Our results allow us to isolate the contributions from photosystem I and the redox mediator, and evaluate photocurrent features (spectral and power dependence, fast transient kinetics) that could be used as a sensing signal to detect other inhibitors and modulators of photosystem I activity.

JTD Keywords: biosensor, herbicide, kinetic model, paraquat, photo-chrono-amperometry, photosystem i, self-assembled monolayer, transparent gold microelectrode, Biosensor, Herbicide, Kinetic model, Paraquat, Photo-chrono-amperometry, Photosystem i, Self-assembled monolayer, Transparent gold microelectrode


Pla, L, Berdún, S, Mir, M, Rivas, L, Miserere, S, Dulay, S, Samitier, J, Eixarch, E, Illa, M, Gratacós, E, (2021). Non-invasive monitoring of pH and oxygen using miniaturized electrochemical sensors in an animal model of acute hypoxia Journal Of Translational Medicine 19, 53

© 2021, The Author(s). Background: One of the most prevalent causes of fetal hypoxia leading to stillbirth is placental insufficiency. Hemodynamic changes evaluated with Doppler ultrasound have been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. As a first step, the present work aimed to evaluate the performance of miniaturized electrochemical sensors in the continuous monitoring of oxygen and pH changes in a model of acute hypoxia-acidosis. Methods: pH and oxygen electrochemical sensors were evaluated in a ventilatory hypoxia rabbit model. The ventilator hypoxia protocol included 3 differential phases: basal (100% FiO2), the hypoxia-acidosis period (10% FiO2) and recovery (100% FiO2). Sensors were tested in blood tissue (ex vivo sensing) and in muscular tissue (in vivo sensing). pH electrochemical and oxygen sensors were evaluated on the day of insertion (short-term evaluation) and pH electrochemical sensors were also tested after 5 days of insertion (long-term evaluation). pH and oxygen sensing were registered throughout the ventilatory hypoxia protocol (basal, hypoxia-acidosis, and recovery) and were compared with blood gas metabolites results from carotid artery catheterization (obtained with the EPOC blood analyzer). Finally, histological assessment was performed on the sensor insertion site. One-way ANOVA was used for the analysis of the evolution of acid-based metabolites and electrochemical sensor signaling results; a t-test was used for pre- and post-calibration analyses; and chi-square analyses for categorical variables. Results: At the short-term evaluation, both the pH and oxygen electrochemical sensors distinguished the basal and hypoxia-acidosis periods in both the in vivo and ex vivo sensing. However, only the ex vivo sensing detected the recovery period. In the long-term evaluation, the pH electrochemical sensor signal seemed to lose sensibility. Finally, histological assessment revealed no signs of alteration on the day of evaluation (short-term), whereas in the long-term evaluation a sub-acute inflammatory reaction adjacent to the implantation site was detected. Conclusions: Miniaturized electrochemical sensors represent a new generation of tools for the continuous monitoring of hypoxia-acidosis, which is especially indicated in high-risk pregnancies. Further studies including more tissue-compatible material would be required in order to improve long-term electrochemical sensing.

JTD Keywords: acute hypoxia-acidosis, continuous monitoring of acid-base status, continuous monitoring of acid–base status, electrochemical sensors, high-risk pregnancies, Acute hypoxia-acidosis, Continuous monitoring of acid–base status, Electrochemical sensors, High-risk pregnancies


Puiggalí-Jou, A, Wedepohl, S, Theune, LE, Alemán, C, Calderón, M, (2021). Effect of conducting/thermoresponsive polymer ratio on multitasking nanogels Materials Science & Engineering C-Materials For Biological Applications 119, 111598

© 2020 Elsevier B.V. Semi-interpenetrated nanogels (NGs) able to release and sense diclofenac (DIC) have been designed to act as photothermal agents with the possibility to ablate cancer cells using mild-temperatures (<45 °C). Combining mild heat treatments with simultaneous chemotherapy appears as a very promising therapeutic strategy to avoid heat resistance or damaging the surrounding tissues. Particularly, NGs consisted on a poly(N-isopropylacrylamide) (PNIPAM) and dendritic polyglycerol (dPG) mesh containing a semi-interpenetrating network (SIPN) of poly(hydroxymethyl 3,4-ethylenedioxythiophene) (PHMeEDOT). The PHMeEDOT acted as photothermal and conducting agent, while PNIPAM-dPG NG provided thermoresponsivity and acted as stabilizer. We studied how semi-interpenetration modified the physicochemical characteristics of the thermoresponsive SIPN NGs and selected the best condition to generate a multifunctional photothermal agent. The thermoswitchable conductiveness of the multifunctional NGs and the redox activity of DIC could be utilized for its electrochemical detection. Besides, as proof of the therapeutic concept, we investigated the combinatorial effect of photothermal therapy (PTT) and DIC treatment using the HeLa cancer cell line in vitro. Within 15 min NIR irradiation without surpassing 45 °C we were able to kill 95% of the cells, demonstrating the potential of SIPN NGs as drug carriers, sensors and agents for mild PTT.

JTD Keywords: cells, cellulose, conducting polymers, controlled delivery, diclofenac, efficiency, electrochemical oxidation, electrochemical sensors, nanogels, nanoparticles, photothermal therapy, pnipam, poly(3,4-ethylenedioxythiophene), Conducting polymers, Electrochemical sensors, Nanogels, Photothermal therapy


Pinheiro, ND, Freire, RT, Conrado, JAM, Batista, AD, Petruci, JFD, (2021). Paper-based optoelectronic nose for identification of indoor air pollution caused by 3D printing thermoplastic filaments Analytica Chimica Acta 1143, 1-8

Commercial printers based on fused deposition modeling (FDM) are widely adopted for 3D printing applications. This method consists of the heating of polymeric filaments over the melting point followed by their deposition onto a solid base to create the desirable 3D structure. Prior investigation using chromatographic techniques has shown that chemical compounds (e.g. VOCs), which can be harmful to users, are emitted during the printing process, producing adverse effects to human health and contributing to indoor air pollution. In this study, we present a simple, inexpensive and disposable paperbased optoelectronic nose (i.e. colorimetric sensor array) to identify the gaseous emission fingerprint of five different types of thermoplastic filaments (ABS, TPU, PETG, TRITAN and PLA) in the indoor environment. The optoelectronic nose is comprised of selected 15 dyes with different chemical properties deposited onto a microfluidic paper-based device with spots of 5 mm in diameter each. Digital images were obtained from an ordinary flatbed scanner, and the RGB information collected before and after air exposure was extracted by using an automated routine designed in MATLAB, in which the color changes provide a unique fingerprint for each filament in 5 min of printing. Reproducibility was obtained in the range of 2.5-10% (RSD). Hierarchical clustering analysis (HCA) and principal component analysis (PCA) were successfully employed, showing suitable discrimination of all studied filaments and the non-polluted air. Besides, air spiked with vapors of the most representative VOCs were analyzed by the optoelectronic nose and visually compared to each filament. The described study shows the potential of the paper-based optoelectronic nose to monitor possible hazard emissions from 3D printers. (C) 2020 Elsevier B.V. All rights reserved.

JTD Keywords: 3d printing, colorimetric sensor array, indoor air pollution, optoelectronic nose, paper-based, 3d printing, Colorimetric sensor array, Emissions, Indoor air pollution, Optoelectronic nose, Paper-based, Thermoplastic filaments


Marrugo-Ramírez, J, Rodríguez-Núñez, M, Marco, MP, Mir, M, Samitier, J, (2021). Kynurenic Acid Electrochemical Immunosensor: Blood-Based Diagnosis of Alzheimer's Disease Biosensors 11, 20

Alzheimer's disease (AD) is a neurodegenerative disorder, characterized by a functional deterioration of the brain. Currently, there are selected biomarkers for its diagnosis in cerebrospinal fluid. However, its extraction has several disadvantages for the patient. Therefore, there is an urgent need for a detection method using sensitive and selective blood-based biomarkers. Kynurenic acid (KYNA) is a potential biomarker candidate for this purpose. The alteration of the KYNA levels in blood has been related with inflammatory processes in the brain, produced as a protective function when neurons are damaged. This paper describes a novel electrochemical immunosensor for KYNA detection, based on successive functionalization multi-electrode array. The resultant sensor was characterized by cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS). The proposed biosensor detects KYNA within a linear calibration range from 10 pM to 100 nM using CA and EIS, obtaining a limit of detection (LOD) of 16.9 pM and 37.6 pM in buffer, respectively, being the lowest reported LOD for this biomarker. Moreover, to assess our device closer to the real application, the developed immunosensor was also tested under human serum matrix, obtaining an LOD of 391.71 pM for CA and 278.8 pM for EIS with diluted serum.

JTD Keywords: alzheimer’s disease (ad), blood analysis, chronoamperometry (ca), electrochemical biosensor, electrochemical impedance spectroscopy (eis), immunosensor, in vitro diagnosis (ivd), kynurenic acid (kyna), Alzheimer’s disease (ad), Blood analysis, Chronoamperometry (ca), Electrochemical biosensor, Electrochemical impedance spectroscopy (eis), Immunosensor, In vitro diagnosis (ivd), Kynurenic acid (kyna), Point of care diagnosis (poc)


Marti, D, Martin-Martinez, E, Torras, J, Bertran, O, Turon, P, Aleman, C, (2021). In silico antibody engineering for SARS-CoV-2 detection Computational And Structural Biotechnology Journal 19, 5525-5534

Engineered immunoglobulin-G molecules (IgGs) are of wide interest for the development of detection elements in protein-based biosensors with clinical applications. The strategy usually employed for the de novo design of such engineered IgGs consists on merging fragments of the three-dimensional structure of a native IgG, which is immobilized on the biosensor surface, and of an antibody with an exquisite target specificity and affinity. In this work conventional and accelerated classical molecular dynamics (cMD and aMD, respectively) simulations have been used to propose two IgG-like antibodies for COVID-19 detection. More specifically, the crystal structure of the IgG1 B12 antibody, which inactivates the human immunodeficiency virus-1, has been merged with the structure of the antibody CR3022 Fab tightly bounded to SARS-CoV-2 receptor-binding domain (RBD) and the structure of the 5309 antibody Fab fragment complexed with SARS-CoV-2 RBD. The two constructed antibodies, named IgG1-CR3022 and IgG1-S309, respectively, have been immobilized on a stable gold surface through a linker. Analyses of the influence of both the merging strategy and the substrate on the stability of the two constructs indicate that the IgG1-S309 antibody better preserves the neutralizing structure than the IgG1-CR3022 one. Overall, results indicate that the IgG1-S309 is appropriated for the generation of antibody based sensors for COVID-19 diagnosis. (C) 2021 The Author(s). Published by Elsevier B.V. on behalf of Research Network of Computational and Structural Biotechnology.

JTD Keywords: cr3022, igg1, molecular engineering, s309, Antibodies, Antibody engineering, Biosensors, Chemical detection, Clinical application, Cov, Cr3022, Crystal structure, Design, Diseases, Gold nanoparticles, Igg1, Igg1 antibody, Immobilization, Immunoglobulin g, Immunosensor, In-silico, Merging, Molecular dynamics, Molecular engineering, Orientation, Protein-based biosensors, Receptor-binding domains, S309, Sars, Sensor, Spike protein, Target, Vaccine, Viruses


Blancas, Maria, Maffei, Giovanni, Sánchez-Fibla, Martí, Vouloutsi, Vasiliki, Verschure, P., (2020). Collaboration variability in autism spectrum disorder Frontiers in Human Neuroscience 14, (412), 559793

This paper addresses how impairments in prediction in young adults with autism spectrum disorder (ASD) relate to their behavior during collaboration. To assess it, we developed a task where participants play in collaboration with a synthetic agent to maximize their score. The agent’s behavior changes during the different phases of the game, requiring participants to model the agent’s sensorimotor contingencies to play collaboratively. Our results (n = 30, 15 per group) show differences between autistic and neurotypical individuals in their behavioral adaptation to the other partner. Contrarily, there are no differences in the self-reports of that collaboration.

JTD Keywords: Autism, Prediction, Collaboration, Sensorimotor contingencies, Neurodiversity


Ruiz-Vega, G., Arias-Alpízar, K., de la Serna, E., Borgheti-Cardoso, L. N., Sulleiro, E., Molina, I., Fernàndez-Busquets, X., Sánchez-Montalvá, A., del Campo, F. J., Baldrich, E., (2020). Electrochemical POC device for fast malaria quantitative diagnosis in whole blood by using magnetic beads, Poly-HRP and microfluidic paper electrodes Biosensors and Bioelectronics 150, 111925

Malaria, a parasitic infection caused by Plasmodium parasites and transmitted through the bite of infected female Anopheles mosquitos, is one of the main causes of mortality in many developing countries. Over 200 million new infections and nearly half a million deaths are reported each year, and more than three billion people are at risk of acquiring malaria worldwide. Nevertheless, most malaria cases could be cured if detected early. Malaria eradication is a top priority of the World Health Organisation. However, achieving this goal will require mass population screening and treatment, which will be hard to accomplish with current diagnostic tools. We report an electrochemical point-of-care device for the fast, simple and quantitative detection of Plasmodium falciparum lactate dehydrogenase (PfLDH) in whole blood samples. Sample analysis includes 5-min lysis to release intracellular parasites, and stirring for 5 more min with immuno-modified magnetic beads (MB) along with an immuno-modified signal amplifier. The rest of the magneto-immunoassay, including sample filtration, MB washing and electrochemical detection, is performed at a disposable paper electrode microfluidic device. The sensor provides PfLDH quantitation down to 2.47 ng mL−1 in spiked samples and for 0.006–1.5% parasitemias in Plasmodium-infected cultured red blood cells, and discrimination between healthy individuals and malaria patients presenting parasitemias >0.3%. Quantitative malaria diagnosis is attained with little user intervention, which is not achieved by other diagnostic methods.

JTD Keywords: Electrochemical magneto-immunosensor, Malaria quantitative diagnosis, Paper microfluidic electrode, Plasmodium LDH, Point-of-care (POC) testing


Burgués, Javier, Marco, Santiago, (2020). Environmental chemical sensing using small drones: A review Science of The Total Environment 748, 141172

Recent advances in miniaturization of chemical instrumentation and in low-cost small drones are catalyzing exponential growth in the use of such platforms for environmental chemical sensing applications. The versatility of chemically sensitive drones is reflected by their rapid adoption in scientific, industrial, and regulatory domains, such as in atmospheric research studies, industrial emission monitoring, and in enforcement of environmental regulations. As a result of this interdisciplinarity, progress to date has been reported across a broad spread of scientific and non-scientific databases, including scientific journals, press releases, company websites, and field reports. The aim of this paper is to assemble all of these pieces of information into a comprehensive, structured and updated review of the field of chemical sensing using small drones. We exhaustively review current and emerging applications of this technology, as well as sensing platforms and algorithms developed by research groups and companies for tasks such as gas concentration mapping, source localization, and flux estimation. We conclude with a discussion of the most pressing technological and regulatory limitations in current practice, and how these could be addressed by future research.

JTD Keywords: Unmanned aircraft systems, Remotely piloted aircraft systems, Chemical sensors, Gas sensors, Environmental monitoring, Industrial emission monitoring


Burgués, Javier, Marco, Santiago, (2020). Feature extraction for transient chemical sensor signals in response to turbulent plumes: Application to chemical source distance prediction Sensors and Actuators B: Chemical 320, 128235

This paper describes the design of a linear phase low-pass differentiator filter with a finite impulse response (FIR) for extracting transient features of gas sensor signals (the so-called “bouts”). The detection of these bouts is relevant for estimating the distance of a gas source in a turbulent plume. Our current proposal addresses the shortcomings of previous ‘bout’ estimation methods, namely: (i) they were based in non-causal digital filters precluding real time operation, (ii) they used non-linear phase filters leading to waveform distortions and (iii) the smoothing action was achieved by two filters in cascade, precluding an easy tuning of filter performance. The presented method is based on a low-pass FIR differentiator, plus proper post-processing, allowing easy algorithmic implementation for real-time robotic exploration. Linear phase filters preserve signal waveform in the bandpass region for maximum reliability concerning both ‘bout’ detection and amplitude estimation. As a case study, we apply the proposed filter to predict the source distance from recordings obtained with metal oxide (MOX) gas sensors in a wind tunnel. We first perform a joint optimization of the cut-off frequency of the filter and the bout amplitude threshold, for different wind speeds, uncovering interesting relationships between these two parameters. We demonstrate that certain combinations of parameters can reduce the prediction error to 8 cm (in a distance range of 1.45 m) improving previously reported performances in the same dataset by a factor of 2.5. These results are benchmarked against traditional source distance estimators such as the mean, variance and maximum of the response. We also study how the length of the measurement window affects the performance of different signal features, and how to select the filter parameters to make the predictive models more robust to changes in wind speed. Finally, we provide a MATLAB implementation of the bout detection algorithm and all analysis code used in this study.

JTD Keywords: Gas sensors, Differentiator, Low pass filter, Metal oxide semiconductor, MOX sensors, Signal processing, Feature extraction, Gas source localization, Robotics


Sánchez-Fibla, M., Forestier, S., Moulin-Frier, C., Puigbò, J. Y., Verschure, P., (2020). From motor to visually guided bimanual affordance learning Adaptive Behavior 28, (2), 63-78

The mechanisms of how the brain orchestrates multi-limb joint action have yet to be elucidated and few computational sensorimotor (SM) learning approaches have dealt with the problem of acquiring bimanual affordances. We propose a series of bidirectional (forward/inverse) SM maps and its associated learning processes that generalize from uni- to bimanual interaction (and affordances) naturally, reinforcing the motor equivalence property. The SM maps range from a SM nature to a solely sensory one: full body control, delta SM control (through small action changes), delta sensory co-variation (how body-related perceptual cues covariate with object-related ones). We make several contributions on how these SM maps are learned: (1) Context and Behavior-Based Babbling: generalizing goal babbling to the interleaving of absolute and local goals including guidance of reflexive behaviors; (2) Event-Based Learning: learning steps are driven by visual, haptic events; and (3) Affordance Gradients: the vectorial field gradients in which an object can be manipulated. Our modeling of bimanual affordances is in line with current robotic research in forward visuomotor mappings and visual servoing, enforces the motor equivalence property, and is also consistent with neurophysiological findings like the multiplicative encoding scheme.

JTD Keywords: Affordances, Bimanual affordances, Goal babbling, Interlimb coordination, Motor equivalence, Sensorimotor learning


Burgués, Javier, Hernández, Victor, Lilienthal, Achim J., Marco, Santiago, (2020). Gas distribution mapping and source localization using a 3D grid of metal oxide semiconductor sensors Sensors and Actuators B: Chemical 304, 127309

The difficulty to obtain ground truth (i.e. empirical evidence) about how a gas disperses in an environment is one of the major hurdles in the field of mobile robotic olfaction (MRO), impairing our ability to develop efficient gas source localization strategies and to validate gas distribution maps produced by autonomous mobile robots. Previous ground truth measurements of gas dispersion have been mostly based on expensive tracer optical methods or 2D chemical sensor grids deployed only at ground level. With the ever-increasing trend towards gas-sensitive aerial robots, 3D measurements of gas dispersion become necessary to characterize the environment these platforms can explore. This paper presents ten different experiments performed with a 3D grid of 27 metal oxide semiconductor (MOX) sensors to visualize the temporal evolution of gas distribution produced by an evaporating ethanol source placed at different locations in an office room, including variations in height, release rate and air flow. We also studied which features of the MOX sensor signals are optimal for predicting the source location, considering different lengths of the measurement window. We found strongly time-varying and counter-intuitive gas distribution patterns that disprove some assumptions commonly held in the MRO field, such as that heavy gases disperse along ground level. Correspondingly, ground-level gas distributions were rarely useful for localizing the gas source and elevated measurements were much more informative. We make the dataset and the code publicly available to enable the community to develop, validate, and compare new approaches related to gas sensing in complex environments.

JTD Keywords: Mobile robotic olfaction, Metal oxide gas sensors, Signal processing, Sensor networks, Gas source localization, Gas distribution mapping


Rivas, L., Dulay, S., Miserere, S., Pla, L., Marin, S. B., Parra, J., Eixarch, E., Gratacós, E., Illa, M., Mir, M., Samitier, J., (2020). Micro-needle implantable electrochemical oxygen sensor: ex-vivo and in-vivo studies Biosensors and Bioelectronics 153, 112028

Oxygen is vital for energy metabolism in mammals and the variability of the concentration is considered a clinical alert for a wide range of metabolic malfunctions in medicine. In this article, we describe the development and application of a micro-needle implantable platinum-based electrochemical sensor for measuring partial pressure of oxygen in intramuscular tissue (in-vivo) and vascular blood (ex-vivo). The Pt-Nafion® sensor was characterized morphological and electrochemically showing a higher sensitivity of −2.496 nA/mmHg (−1.495 nA/μM) when comparing with its bare counterpart. Our sensor was able to discriminate states with different oxygen partial pressures (pO2) for ex-vivo (blood) following the same trend of the commercial gas analyzer used as standard. For in-vivo (intramuscular) experiments, since there is not a gold standard for measuring pO2 in tissue, it was not possible to correlate the obtained currents with the pO2 in tissue. However, our sensor was able to detect clear statistical differences of O2 between hyperoxia and hypoxia states in tissue.

JTD Keywords: Hypoxia, Implantable sensor, In-vivo test, Ischemia, Nafion, Oxygen sensor


Palacio, F., Fonollosa, J., Burgués, J., Gomez, J. M., Marco, S., (2020). Pulsed-temperature metal oxide gas sensors for microwatt power consumption IEEE Access 8, 70938-70946

Metal Oxide (MOX) gas sensors rely on chemical reactions that occur efficiently at high temperatures, resulting in too-demanding power requirements for certain applications. Operating the sensor under a Pulsed-Temperature Operation (PTO), by which the sensor heater is switched ON and OFF periodically, is a common practice to reduce the power consumption. However, the sensor performance is degraded as the OFF periods become larger. Other research works studied, generally, PTO schemes applying waveforms to the heater with time periods of seconds and duty cycles above 20%. Here, instead, we explore the behaviour of PTO sensors working under aggressive schemes, reaching power savings of 99% and beyond with respect to continuous heater stimulation. Using sensor sensitivity and the limit of detection, we evaluated four Ultra Low Power (ULP) sensors under different PTO schemes exposed to ammonia, ethylene, and acetaldehyde. Results show that it is possible to operate the sensors with total power consumption in the range of microwatts. Despite the aggressive power reduction, sensor sensitivity suffers only a moderate decline and the limit of detection may degrade up to a factor five. This is, however, gas-dependent and should be explored on a case-by-case basis since, for example, the same degradation has not been observed for ammonia. Finally, the run-in time, i.e., the time required to get a stable response immediately after switching on the sensor, increases when reducing the power consumption, from 10 minutes to values in the range of 10–20 hours for power consumptions smaller than 200 microwatts.

JTD Keywords: Robot sensing systems, Temperature sensors, Heating systems, Gas detectors, Power demand, Sensitivity, Electronic nose, gas sensors, low-power operation, machine olfaction, pulsed-temperature operation, temperature modulation


Lanzalaco, S., Fabregat, G., Muñoz-Galan, H., Cabrera, J., Muñoz-Pascual, X., Llorca, J., Alemán, C., (2020). Recycled low-density polyethylene for noninvasive glucose monitoring: A proposal for plastic recycling that adds technological value ACS Sustainable Chemistry and Engineering 8, (33), 12554-12560

In this work, we present a successful strategy to convert recycled LDPE films, which usually end up in landfills or leak into the environment, into an advanced biomedical product. More specifically, LDPE films for food packaging have been treated with atmosphere corona discharge plasma for electrochemical detection of glucose. Enzyme-functionalized sensors manufactured using such recycled materials, which act as a mediator capable of electrocommunicating with the glucose oxidase (GOx) enzyme, are able to detect glucose concentrations in sweat and are fully compatible with the levels of such bioanalytes in both healthy and diabetic patients. Covalent immobilization of the GOx enzyme on the plasma-treated LDPE films has been successfully performed using the carbodiimide method, as proved by X-ray photoelectron spectroscopy. Then, the electronic communication between the deeply buried active site of the GOx and the reactive excited species formed at the surface of the plasma-treated LDPE has been demonstrated by linear sweep voltammetry. Finally, cyclic voltammetry in artificial sweat has been used to show that the LDPE-functionalized sensor has a linear response in the concentration of range of 50 μM to 1 mM with a limit of detection of 375 μA·μM–1·cm–2. Comparison of the performance of sensors prepared using recycled (i.e. with additives) and pristine (i.e. without additives) LDPE indicates that the utilization of the former does not require any pretreatment to eliminate additives. The present strategy demonstrates a facile approach for recycling LDPE waste into a high value-added product, which will potentially pave the way for the treatment of plastic waste in the future. Noninvasive glucose sensors based on recycled LDPE may play a crucial role in monitoring diabetes in underdeveloped regions.

JTD Keywords: Biosensors, Diabetes monitoring, High-value recycling, Plasma treatment, Sweat sensors


Moghimiardekani, A., Molina, B. G., Enshaei, H., del Valle, L. J., Pérez-Madrigal, M. M., Estrany, F., Alemán, C., (2020). Semi-interpenetrated hydrogels-microfibers electroactive assemblies for release and real-time monitoring of drugs Macromolecular Bioscience 20, (7), 2000074

Simultaneous drug release and monitoring using a single polymeric platform represents a significant advance in the utilization of biomaterials for therapeutic use. Tracking drug release by real-time electrochemical detection using the same platform is a simple way to guide the dosage of the drug, improve the desired therapeutic effect, and reduce the adverse side effects. The platform developed in this work takes advantage of the flexibility and loading capacity of hydrogels, the mechanical strength of microfibers, and the capacity of conducting polymers to detect the redox properties of drugs. The engineered platform is prepared by assembling two spin-coated layers of poly-γ-glutamic acid hydrogel, loaded with poly(3,4-ethylenedioxythiophene) (PEDOT) microparticles, and separated by a electrospun layer of poly-ε-caprolactone microfibers. Loaded PEDOT microparticles are used as reaction nuclei for the polymerization of poly(hydroxymethyl-3,4-ethylenedioxythiophene) (PHMeDOT), that semi-interpenetrate the whole three layered system while forming a dense network of electrical conduction paths. After demonstrating its properties, the platform is loaded with levofloxacin and its release monitored externally by UV–vis spectroscopy and in situ by using the PHMeDOT network. In situ real-time electrochemical monitoring of the drug release from the engineered platform holds great promise for the development of multi-functional devices for advanced biomedical applications.

JTD Keywords: Biosensors, Conducting polymers, Drug delivery, Poly-γ-glutamic acid, Poly-ε-caprolactone


Sierra, J., Marrugo-Ramírez, J., Rodriguez-Trujillo, R., Mir, M., Samitier, J., (2020). Sensor-integrated microfluidic approaches for liquid biopsies applications in early detection of cancer Sensors 20, (5), 1317

Cancer represents one of the conditions with the most causes of death worldwide. Common methods for its diagnosis are based on tissue biopsies—the extraction of tissue from the primary tumor, which is used for its histological analysis. However, this technique represents a risk for the patient, along with being expensive and time-consuming and so it cannot be frequently used to follow the progress of the disease. Liquid biopsy is a new cancer diagnostic alternative, which allows the analysis of the molecular information of the solid tumors via a body fluid draw. This fluid-based diagnostic method displays relevant advantages, including its minimal invasiveness, lower risk, use as often as required, it can be analyzed with the use of microfluidic-based platforms with low consumption of reagent, and it does not require specialized personnel and expensive equipment for the diagnosis. In recent years, the integration of sensors in microfluidics lab-on-a-chip devices was performed for liquid biopsies applications, granting significant advantages in the separation and detection of circulating tumor nucleic acids (ctNAs), circulating tumor cells (CTCs) and exosomes. The improvements in isolation and detection technologies offer increasingly sensitive and selective equipment’s, and the integration in microfluidic devices provides a better characterization and analysis of these biomarkers. These fully integrated systems will facilitate the generation of fully automatized platforms at low-cost for compact cancer diagnosis systems at an early stage and for the prediction and prognosis of cancer treatment through the biomarkers for personalized tumor analysis.

JTD Keywords: Cancer, Circulant tumor cells (CTC), Circulant tumor DNA (ctDNA), Exosomes, Liquid biopsy, Microfluidic, Sensors


Vouloutsi, V., Chesson, A., Blancas, M., Guerrero, O., Verschure, P., (2020). The use of social sensorimotor contingencies in humanoid robots Biomimetic and Biohybrid Systems 9th International Conference, Living Machines 2020 (Lecture Notes in Computer Science) , Springer International Publishing (Freiburg, Germany) 12413, 378-389

This pilot study investigates the role of social sensorimotor contingencies as exhibited from a humanoid robot to allow mutual understanding and social entrainment in a group social activity. The goal is to evaluate whether sensorimotor contingencies can lead to transparent and understandable interactions while we explore the dimension of personality. We propose the task of taking a selfie with a robot and a group of humans as the benchmark to evaluate the social sensorimotor contingencies displayed. We have constructed two models of interaction with an introverted and extroverted robot. We also seek to address the gap in research in context and personality of social sensorimotor contingencies in HRI and contribute to the field of personality in social robotics by determining what type of behaviour of the robot attracts certain personalities in humans in group settings. Although the sample size was small, and there were no significant differences between conditions, results suggest that the expression of sensorimotor contingencies can lead to successful coupling and interactions.

JTD Keywords: Human-robot interaction, Personality, Social robots, Social sensorimotor contingencies


Vouloutsi, Vasiliki, Mura, Anna, Tauber, F., Speck, T., Prescott, T. J., Verschure, P., (2020). Biomimetic and Biohybrid Systems 9th International Conference, Living Machines 2020, Freiburg, Germany, July 28–30, 2020, Proceedings , Springer, Cham (Lausanne, Switzerland) 12413, 1-428

This book constitutes the proceedings of the )th International Conference on Biomimetic and Biohybrid Systems, Living Machines 2020, held in Freiburg, Germany, in July 2020. Due to COVID-19 pandemic the conference was held virtually. The 32 full and 7 short papers presented in this volume were carefully reviewed and selected from 45 submissions. They deal with research on novel life-like technologies inspired by the scientific investigation of biological systems, biomimetics, and research that seeks to interface biological and artificial systems to create biohybrid systems.

JTD Keywords: Artificial intelligence, Soft robotics, Biomimetics, Insect navigation, Synthetic nervous system, Computer vision, Bio-inspired materials, Visual homing, Locomotion+, Image processing, Intelligent robots, Human-robot interaction, Machine learning, Snake robot, Mobile robots, Robotic systems, Drosophila, Robots, Sensors, Signal processing


Hernández-Albors, Alejandro, Castaño, Albert G., Fernández-Garibay, Xiomara, Ortega, María Alejandra, Balaguer, Jordina, Ramón-Azcón, Javier, (2019). Microphysiological sensing platform for an in-situ detection of tissue-secreted cytokines Biosensors and Bioelectronics: X 2, 100025

Understanding the protein-secretion dynamics from single, specific tissues is critical toward the advancement of disease detection and treatments. However, such secretion dynamics remain difficult to measure in vivo due to the uncontrolled contributions from other tissue populations. Here, we describe an integrated platform designed for the reliable, near real-time measurements of cytokines secreted from an in vitro single-tissue model. In our setup, we grow 3D biomimetic tissues to discretize cytokine source, and we separate them from a magnetic microbead-based biosensing system using a Transwell insert. This design integrates physiochemically controlled biological activity, high-sensitivity protein detection (LOD < 20 pg mL−1), and rapid protein diffusion to enable non-invasive, near real-time measurements. To showcase the specificity and sensitivity of the system, we use our setup to probe the inflammatory process related to the protein Interleukine 6 (IL-6) and to the Tumor Necrosis Factor (TNF-α). We show that our setup can monitor the time-dependence profile of IL-6 and TNF-α secretion that results from the electrical and chemical stimulation of 3D skeletal muscle tissues. We demonstrate a novel and affordable methodology for discretizing the secretion kinetics of specific tissues for advancing metabolic-disorder studies and drug-screening applications.

JTD Keywords: Microphysiological tissues, Tissue engineering, Electrochemical, biosensors, Magnetic particles, Skeletal muscle, Electric stimulation


Patiño, Tania, Porchetta, Alessandro, Jannasch, Anita, Lladó, Anna, Stumpp, Tom, Schäffer, Erik, Ricci, Francesco, Sánchez, Samuel, (2019). Self-sensing enzyme-powered micromotors equipped with pH-responsive DNA nanoswitches Nano Letters 19, (6), 3440-3447

Biocatalytic micro- and nanomotors have emerged as a new class of active matter self-propelled through enzymatic reactions. The incorporation of functional nanotools could enable the rational design of multifunctional micromotors for simultaneous real-time monitoring of their environment and activity. Herein, we report the combination of DNA nanotechnology and urease-powered micromotors as multifunctional tools able to swim, simultaneously sense the pH of their surrounding environment, and monitor their intrinsic activity. With this purpose, a FRET-labeled triplex DNA nanoswitch for pH sensing was immobilized onto the surface of mesoporous silica-based micromotors. During self-propulsion, urea decomposition and the subsequent release of ammonia led to a fast pH increase, which was detected by real-time monitoring of the FRET efficiency through confocal laser scanning microscopy at different time points (i.e., 30 s, 2 and 10 min). Furthermore, the analysis of speed, enzymatic activity, and propulsive force displayed a similar exponential decay, matching the trend observed for the FRET efficiency. These results illustrate the potential of using specific DNA nanoswitches not only for sensing the micromotors’ surrounding microenvironment but also as an indicator of the micromotor activity status, which may aid to the understanding of their performance in different media and in different applications.

JTD Keywords: Micromotors, DNA-nanoswitch, pH detection, Self-propulsion, Nanosensors, Nanomotors


Roux, Anabel-Lise Lee, Quiroga, Xarxa, Walani, Nikhil, Arroyo, Marino, Roca-Cusachs, Pere, (2019). The plasma membrane as a mechanochemical transducer Philosophical Transactions of the Royal Society B: Biological Sciences 374, (1779), 20180221

Cells are constantly submitted to external mechanical stresses, which they must withstand and respond to. By forming a physical boundary between cells and their environment that is also a biochemical platform, the plasma membrane (PM) is a key interface mediating both cellular response to mechanical stimuli, and subsequent biochemical responses. Here, we review the role of the PM as a mechanosensing structure. We first analyse how the PM responds to mechanical stresses, and then discuss how this mechanical response triggers downstream biochemical responses. The molecular players involved in PM mechanochemical transduction include sensors of membrane unfolding, membrane tension, membrane curvature or membrane domain rearrangement. These sensors trigger signalling cascades fundamental both in healthy scenarios and in diseases such as cancer, which cells harness to maintain integrity, keep or restore homeostasis and adapt to their external environment.

JTD Keywords: Plasma membrane, Mechanotransduction, Membrane tension, Mechanosensor


Castillo-Escario, Y., Ferrer-Lluis, I., Montserrat, J. M., Jané, R., (2019). Entropy analysis of acoustic signals recorded with a smartphone for detecting apneas and hypopneas: A comparison with a commercial system for home sleep apnea diagnosis IEEE Access 7, 128224-128241

Obstructive sleep apnea (OSA) is a prevalent disease, but most patients remain undiagnosed and untreated. Here we propose analyzing smartphone audio signals for screening OSA patients at home. Our objectives were to: (1) develop an algorithm for detecting silence events and classifying them into apneas or hypopneas; (2) evaluate the performance of this system; and (3) compare the information provided with a type 3 portable sleep monitor, based mainly on nasal airflow. Overnight signals were acquired simultaneously by both systems in 13 subjects (3 healthy subjects and 10 OSA patients). The sample entropy of audio signals was used to identify apnea/hypopnea events. The apnea-hypopnea indices predicted by the two systems presented a very high degree of concordance and the smartphone correctly detected and stratified all the OSA patients. An event-by-event comparison demonstrated good agreement between silence events and apnea/hypopnea events in the reference system (Sensitivity = 76%, Positive Predictive Value = 82%). Most apneas were detected (89%), but not so many hypopneas (61%). We observed that many hypopneas were accompanied by snoring, so there was no sound reduction. The apnea/hypopnea classification accuracy was 70%, but most discrepancies resulted from the inability of the nasal cannula of the reference device to record oral breathing. We provided a spectral characterization of oral and nasal breathing to correct this effect, and the classification accuracy increased to 82%. This novel knowledge from acoustic signals may be of great interest for clinical practice to develop new non-invasive techniques for screening and monitoring OSA patients at home.

JTD Keywords: Sleep apnea, Acoustics, Monitoring, Entropy, Sensors, Microphones, Acoustics, Biomedical signal processing, mHealth, Monitoring, Sleep apnea, Smartphone


Burgués, J., Marco, S., (2019). Wind-independent estimation of gas source distance from transient features of metal oxide sensor signals IEEE Access 7, 140460-140469

The intermittency of the instantaneous concentration of a turbulent chemical plume is a fundamental cue for estimating the chemical source distance using chemical sensors. Such estimate is useful in applications such as environmental monitoring or localization of fugitive gas emissions by mobile robots or sensor networks. However, the inherent low-pass filtering of metal oxide (MOX) gas sensors-typically used in odor-guided robots and dense sensor networks due to their low cost, weight and size-hinders the quantification of concentration intermittency. In this paper, we design a digital differentiator to invert the low-pass dynamics of the sensor response, thus obtaining a much faster signal from which the concentration intermittency can be effectively computed. Using a fast photo-ionization detector as a reference instrument, we demonstrate that the filtered signal is a good approximation of the instantaneous concentration in a real turbulent plume. We then extract transient features from the filtered signal-the so-called “bouts”-to predict the chemical source distance, focusing on the optimization of the filter parameters and the noise threshold to make the predictions robust against changing wind conditions. This represents an advantage over previous bout-based models which require wind measurements-typically taken with expensive and bulky anemometers-to produce accurate predictions. The proposed methodology is demonstrated in a wind tunnel scenario where a MOX sensor is placed at various distances downwind of an emitting chemical source and the wind speed varies in the range 10-34 cm/s. The results demonstrate that models optimized with our methodology can provide accurate source distance predictions at different wind speeds.

JTD Keywords: Gas detectors, Chemical sensors, Signal processing, Machine learning, Time series analysis


Palacín, J., Martínez, D., Clotet, E., Pallejà, T., Burgués, J., Fonollosa, J., Pardo, A., Marco, Santiago, (2019). Application of an array of metal-oxide semiconductor gas sensors in an assistant personal robot for early gas leak detection Sensors 19, (9), 1957

This paper proposes the application of a low-cost gas sensor array in an assistant personal robot (APR) in order to extend the capabilities of the mobile robot as an early gas leak detector for safety purposes. The gas sensor array is composed of 16 low-cost metal-oxide (MOX) gas sensors, which are continuously in operation. The mobile robot was modified to keep the gas sensor array always switched on, even in the case of battery recharge. The gas sensor array provides 16 individual gas measurements and one output that is a cumulative summary of all measurements, used as an overall indicator of a gas concentration change. The results of preliminary experiments were used to train a partial least squares discriminant analysis (PLS-DA) classifier with air, ethanol, and acetone as output classes. Then, the mobile robot gas leak detection capabilities were experimentally evaluated in a public facility, by forcing the evaporation of (1) ethanol, (2) acetone, and (3) ethanol and acetone at different locations. The positive results obtained in different operation conditions over the course of one month confirmed the early detection capabilities of the proposed mobile system. For example, the APR was able to detect a gas leak produced inside a closed room from the external corridor due to small leakages under the door induced by the forced ventilation system of the building.

JTD Keywords: Metal-oxide semiconductor, Gas sensor, Gas leak detection, Assistant personal robot, Mobile robot


Martinez, Dominique, Burgués, Javier, Marco, Santiago, (2019). Fast measurements with MOX sensors: A least-squares approach to blind deconvolution Sensors 19, (18), 4029

Metal oxide (MOX) sensors are widely used for chemical sensing due to their low cost, miniaturization, low power consumption and durability. Yet, getting instantaneous measurements of fluctuating gas concentration in turbulent plumes is not possible due to their slow response time. In this paper, we show that the slow response of MOX sensors can be compensated by deconvolution, provided that an invertible, parametrized, sensor model is available. We consider a nonlinear, first-order dynamic model that is mathematically tractable for MOX identification and deconvolution. By transforming the sensor signal in the log-domain, the system becomes linear in the parameters and these can be estimated by the least-squares techniques. Moreover, we use the MOX diversity in a sensor array to avoid training with a supervised signal. The information provided by two (or more) sensors, exposed to the same flow but responding with different dynamics, is exploited to recover the ground truth signal (gas input). This approach is known as blind deconvolution. We demonstrate its efficiency on MOX sensors recorded in turbulent plumes. The reconstructed signal is similar to the one obtained with a fast photo-ionization detector (PID). The technique is thus relevant to track a fast-changing gas concentration with MOX sensors, resulting in a compensated response time comparable to that of a PID.

JTD Keywords: MOX sensors, Blind deconvolution, Blind identification, Least-squares, Turbulent plumes.


Burgués, Javier, Hernández, Victor, Lilienthal, Achim J., Marco, Santiago, (2019). Smelling nano aerial vehicle for gas source localization and mapping Sensors 19, (3), 478

This paper describes the development and validation of the currently smallest aerial platform with olfaction capabilities. The developed Smelling Nano Aerial Vehicle (SNAV) is based on a lightweight commercial nano-quadcopter (27 g) equipped with a custom gas sensing board that can host up to two in situ metal oxide semiconductor (MOX) gas sensors. Due to its small form-factor, the SNAV is not a hazard for humans, enabling its use in public areas or inside buildings. It can autonomously carry out gas sensing missions of hazardous environments inaccessible to terrestrial robots and bigger drones, for example searching for victims and hazardous gas leaks inside pockets that form within the wreckage of collapsed buildings in the aftermath of an earthquake or explosion. The first contribution of this work is assessing the impact of the nano-propellers on the MOX sensor signals at different distances to a gas source. A second contribution is adapting the ‘bout’ detection algorithm, proposed by Schmuker et al. (2016) to extract specific features from the derivative of the MOX sensor response, for real-time operation. The third and main contribution is the experimental validation of the SNAV for gas source localization (GSL) and mapping in a large indoor environment (160 m2) with a gas source placed in challenging positions for the drone, for example hidden in the ceiling of the room or inside a power outlet box. Two GSL strategies are compared, one based on the instantaneous gas sensor response and the other one based on the bout frequency. From the measurements collected (in motion) along a predefined sweeping path we built (in less than 3 min) a 3D map of the gas distribution and identified the most likely source location. Using the bout frequency yielded on average a higher localization accuracy than using the instantaneous gas sensor response (1.38 m versus 2.05 m error), however accurate tuning of an additional parameter (the noise threshold) is required in the former case. The main conclusion of this paper is that a nano-drone has the potential to perform gas sensing tasks in complex environments.

JTD Keywords: Robotics, Signal processing, Electronics, Gas source localization, Gas distribution mapping, Gas sensors, Drone, UAV, MOX sensor, Quadcopter


Grechuta, Klaudia, Ulysse, Laura, Rubio Ballester, Belén, Verschure, Paul, (2019). Self beyond the body: Action-driven and task-relevant purely distal cues modulate performance and body ownership Frontiers in Human Neuroscience 13, Article 91

Our understanding of body ownership largely relies on the so-called Rubber Hand Illusion (RHI). In this paradigm, synchronous stroking of the real and the rubber hands leads to an illusion of ownership of the rubber hand provided that it is physically, anatomically, and spatially plausible. Self-attribution of an artificial hand also occurs during visuomotor synchrony. In particular, participants experience ownership over a virtual or a rubber hand when the visual feedback of self-initiated movements follows the trajectory of the instantiated motor commands, such as in the Virtual Hand Illusion (VHI) or the moving Rubber Hand Illusion (mRHI). Evidence yields that both when the cues are triggered externally (RHI) and when they result from voluntary actions (VHI and mRHI), the experience of ownership is established through bottom-up integration and top-down prediction of proximodistal cues (visuotactile or visuomotor) within the peripersonal space. It seems, however, that depending on whether the sensory signals are externally (RHI) or self-generated (VHI and mRHI), the top-down expectation signals are qualitatively different. On the one hand, in the RHI the sensory correlations are modulated by top-down influences which constitute empirically induced priors related to the internal (generative) model of the body. On the other hand, in the VHI and mRHI body ownership is actively shaped by processes which allow for continuous comparison between the expected and the actual sensory consequences of the actions. Ample research demonstrates that the differential processing of the predicted and the reafferent information is addressed by the central nervous system via an internal (forward) model or corollary discharge. Indeed, results from the VHI and mRHI suggest that, in action-contexts, the mechanism underlying body ownership could be similar to the forward model. Crucially, forward models integrate across all self-generated sensory signals including not only proximodistal (i.e., visuotactile or visuomotor) but also purely distal sensory cues (i.e., visuoauditory). Thus, if body ownership results from a consistency of a forward model, it will be affected by the (in)congruency of purely distal cues provided that they inform about action-consequences and are relevant to a goal-oriented task. Specifically, they constitute a corrective error signal. Here, we explicitly addressed this question. To test our hypothesis, we devised an embodied virtual reality-based motor task where action outcomes were signaled by distinct auditory cues. By manipulating the cues with respect to their spatial, temporal and semantic congruency, we show that purely distal (visuoauditory) feedback which violates predictions about action outcomes compromises both performance and body ownership. These results demonstrate, for the first time, that body ownership is influenced by not only externally and self-generated cues which pertain to the body within the peripersonal space but also those arising outside of the body. Hence, during goal-oriented tasks body ownership may result from the consistency of forward models.

JTD Keywords: Body ownership, Internal forward model, Goal-oriented behavior, Multisensory integration, Top-down prediction


Burgues, J., Marco, S., (2019). Feature extraction of gas sensor signals for gas source localization ISOEN 2019 18th International Symposium on Olfaction and Electronic Nose , IEEE (Fukuoka, Japan) , 1-3

This paper explores which signal features of a gas sensor are optimum for assessing the proximity to a gas source in an open environment. Specifically, we compare three statistical descriptors of the signal (mean, variance and maximum response) against the 'bout' frequency, a feature computed in the derivative of the response. The experimental setup includes a generator of turbulent plumes and a sensing board composed of three metal oxide (MOX) sensors of different types. The main conclusion is that the maximum response is the most robust feature across the three sensors. The 'bout' frequency can be very sensitive to an additional parameter (the noise threshold).

JTD Keywords: Feature extraction, Gas plume, Gas sensors, Gas source localization, MOX, Signal processing


Burgues, J., Valdez, L. F., Marco, S., (2019). High-bandwidth e-nose for rapid tracking of turbulent plumes ISOEN 2019 18th International Symposium on Olfaction and Electronic Nose , IEEE (Fukuoka, Japan) , 1-3

The low bandwidth of metal oxide semiconductor (MOX) sensors (<0.1 Hz) is a major hurdle to gas source localization (GSL) in turbulent environments where detection of intermittent odor patches is key. We present a fast-response miniaturized electronic nose (Fast-eNose) composed of four naked MOX sensors and a digital band-pass filter that can boost the bandwidth of the system close to 1 Hz. The device was attached to a fast photo-ionization detector (330 Hz) to quantify the response time during exposure to turbulent gas plumes. The results indicate that the digital filter can improve the response time by at least a factor of 4, bringing new possibilities to mobile robot olfaction.

JTD Keywords: CFD, Gas plume, Gas sensors, MOX, Response time, Signal processing


Martinez-Hernandez, Uriel, Vouloutsi, Vasiliki, Mura, Anna, Mangan, Michael, Asada, Minoru, Prescott, T. J., Verschure, P., (2019). Biomimetic and Biohybrid Systems 8th International Conference, Living Machines 2019, Nara, Japan, July 9–12, 2019, Proceedings , Springer, Cham (Lausanne, Switzerland) 11556, 1-384

This book constitutes the proceedings of the 8th International Conference on Biomimetic and Biohybrid Systems, Living Machines 2019, held in Nara, Japan, in July 2019. The 26 full and 16 short papers presented in this volume were carefully reviewed and selected from 45 submissions. They deal with research on novel life-like technologies inspired by the scientific investigation of biological systems, biomimetics, and research that seeks to interface biological and artificial systems to create biohybrid systems.

JTD Keywords: Artificial intelligence, Biomimetics, Computer architecture, Human robot interaction, Human-Computer Interaction (HCI), Humanoid robot, Image processing, Learning algorithms, Mobile robots, Multipurpose robots, Neural networks, Quadruped robots, Reinforcement learning, Robot learning, Robotics, Robots, Sensor, Sensors, Swarm robotics, User interfaces


Samitier, Josep, Correia, A., (2019). Biomimetic Nanotechnology for Biomedical Applications (NanoBio&Med 2018) Biomimetics MDPI

Emerging nanobiotechnologies can offer solutions to the current and future challenges in medicine. By covering topics from regenerative medicine, tissue engineering, drug delivery, bionanofabrication, and molecular biorecognition, this Special Issue aims to provide an update on the trends in nanomedicine and drug delivery using biomimetic approaches, and the development of novel biologically inspired devices for the safe and effective diagnosis, prevention, and treatment of disease.

JTD Keywords: Bioinspired nanotechnologies, Bionanofabrication, Bio-nano measurement and microscopy, Nanomaterials for biological and medical applications, Nanoassemblies, Nanostructured surfaces, Drug delivery, Nanobioelectronics, Integrated systems/nanobiosensors, Nanotoxicology, Graphene-based applications


Pérez, Judit, Dulay, Samuel, Mir, M., Samitier, Josep, (2018). Molecular architecture for DNA wiring Biosensors and Bioelectronics 121, 54-61

Detection of the hybridisation events is of great importance in many different biotechnology applications such as diagnosis, computing, molecular bioelectronics, and among others. However, one important drawback is the low current of some redox reporters that limits their application. This paper demonstrates the powerful features of molecular wires, in particular the case of S-[4-[2-[4-(2-Phenylethynyl)phenyl]ethynyl]phenyl] thiol molecule and the key role that play the nanometric design of the capture probe linkers to achieve an efficient couple of the DNA complementary ferrocene label with the molecular wire for an effective electron transfer in co-immobilised self-assembled monolayers (SAMs) for DNA hybridisation detection. In this article, the length of the linker capture probe was studied for electron transfer enhancement from the ferrocene-motifs of immobilised molecules towards the electrode surface to obtain higher kinetics in the presence of thiolated molecular wires. The use of the right couple of capture probe linker and molecular wire has found to be beneficial as it helps to amplify eightfold the signal obtained.

JTD Keywords: DNA hybridisation, Bioelectronics, Electron transfer rate constant, Molecular wires, Electrochemistry, Ferrocene, Biosensor


Romeo, Agostino, Moya, Ana, Leung, Tammy S., Gabriel, Gemma, Villa, Rosa, Sánchez, Samuel, (2018). Inkjet printed flexible non-enzymatic glucose sensor for tear fluid analysis Applied Materials Today 10, 133-141

Here, we present a flexible and low-cost inkjet printed electrochemical sensor for enzyme-free glucose analysis. Versatility, short fabrication time and low cost make inkjet printing a valuable alternative to traditional sensor manufacturing techniques. We fabricated electro-chemical glucose sensors by inkjet printing electrodes on a flexible polyethylene terephthalate substrate. CuO microparticles were used to modify our electrodes, leading to a sensitive, stable and cost-effective platform for non-enzymatic detection of glucose. Selectivity, reproducibility, and life-time provided by the CuO functionalization demonstrated that these sensors are reliable tools for personalized diagnostics and self-assessment of an individual's health. The detection of glucose at concentrations matching that of tear fluid allows us to envisage applications in ocular diagnostics, where painless and non-invasive monitoring of diabetes can be achieved by analyzing glucose contained in tears.

JTD Keywords: Inkjet printing, Non-enzymatic sensor, Glucose, Copper oxide, Tear analysis


Solórzano, A., Rodríguez-Pérez, R., Padilla, M., Graunke, T., Fernandez, L., Marco, S., Fonollosa, J., (2018). Multi-unit calibration rejects inherent device variability of chemical sensor arrays Sensors and Actuators B: Chemical 265, 142-154

Inherent sensor variability limits mass-production applications for metal oxide (MOX) gas sensor arrays because calibration for replicas of a sensor array needs to be performed individually. Recently, calibration transfer strategies have been proposed to alleviate calibration costs of new replicas, but they still require the acquisition of transfer samples. In this work, we present calibration models that can be extended to uncalibrated replicas of sensor arrays without acquiring new samples, i.e., general or global calibration models. The developed methodology consists in including multiple replicas of a sensor array in the calibration process such that sensor variability is rejected by the general model. Our approach was tested using replicas of a MOX sensor array in the classification task of six gases and synthetic air, presented at different background humidity and concentration levels. Results showed that direct transfer of individual calibration models provides poor classification accuracy. However, we also found that general calibration models kept predictive performance when were applied directly to new copies of the sensor array. Moreover, we explored, through feature selection, whether particular combinations of sensors and operating temperatures can provide predictive performances equivalent to the calibration model with the complete array, favoring thereby the existence of more robust calibration models.

JTD Keywords: Gas sensor array, MOX sensor, Robust calibration, Calibration transfer, Machine olfaction


Burgués, J., Jiménez-Soto, J. M., Marco, S., (2018). Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models Analytica Chimica Acta 1013, 13-25

The limit of detection (LOD) is a key figure of merit in chemical sensing. However, the estimation of this figure of merit is hindered by the non-linear calibration curve characteristic of semiconductor gas sensor technologies such as, metal oxide (MOX), gasFETs or thermoelectric sensors. Additionally, chemical sensors suffer from cross-sensitivities and temporal stability problems. The application of the International Union of Pure and Applied Chemistry (IUPAC) recommendations for univariate LOD estimation in non-linear semiconductor gas sensors is not straightforward due to the strong statistical requirements of the IUPAC methodology (linearity, homoscedasticity, normality). Here, we propose a methodological approach to LOD estimation through linearized calibration models. As an example, the methodology is applied to the detection of low concentrations of carbon monoxide using MOX gas sensors in a scenario where the main source of error is the presence of uncontrolled levels of humidity.

JTD Keywords: Semiconductor gas sensors, Metal-oxide sensors, Limit of detection, Non-linear, Humidity interference, Temperature modulation


Burgués, Javier, Marco, Santiago, (2018). Multivariate estimation of the limit of detection by orthogonal partial least squares in temperature-modulated MOX sensors Analytica Chimica Acta 1019, 49-64

Metal oxide semiconductor (MOX) sensors are usually temperature-modulated and calibrated with multivariate models such as Partial Least Squares (PLS) to increase the inherent low selectivity of this technology. The multivariate sensor response patterns exhibit heteroscedastic and correlated noise, which suggests that maximum likelihood methods should outperform PLS. One contribution of this paper is the comparison between PLS and maximum likelihood principal components regression (MLPCR) in MOX sensors. PLS is often criticized by the lack of interpretability when the model complexity increases beyond the chemical rank of the problem. This happens in MOX sensors due to cross-sensitivities to interferences, such as temperature or humidity and non-linearity. Additionally, the estimation of fundamental figures of merit, such as the limit of detection (LOD), is still not standardized in multivariate models. Orthogonalization methods, such as Orthogonal Projection to Latent Structures (O-PLS), have been successfully applied in other fields to reduce the complexity of PLS models. In this work, we propose a LOD estimation method based on applying the well-accepted univariate LOD formulas to the scores of the first component of an orthogonal PLS model. The resulting LOD is compared to the multivariate LOD range derived from error-propagation. The methodology is applied to data extracted from temperature-modulated MOX sensors (FIS SB-500-12 and Figaro TGS 3870-A04), aiming at the detection of low concentrations of carbon monoxide in the presence of uncontrolled humidity (chemical noise). We found that PLS models were simpler and more accurate than MLPCR models. Average LOD values of 0.79 ppm (FIS) and 1.06 ppm (Figaro) were found using the approach described in this paper. These values were contained within the LOD ranges obtained with the error-propagation approach. The mean LOD increased to 1.13 ppm (FIS) and 1.59 ppm (Figaro) when considering validation samples collected two weeks after calibration, which represents a 43% and 46% degradation, respectively. The orthogonal score-plot was a very convenient tool to visualize MOX sensor data and to validate the LOD estimates.

JTD Keywords: Metal oxide sensors, Partial least squares, Orthogonal projection to latent structures, Maximum likelihood principal component regression, Limit of detection, Temperature modulation


Fernandez, L., Yan, J., Fonollosa, J., Burgués, J., Gutierrez, A., Marco, S., (2018). A practical method to estimate the resolving power of a chemical sensor array: Application to feature selection Frontiers in Chemistry 6, Article 209

A methodology to calculate analytical figures of merit is not well established for detection systems that are based on sensor arrays with low sensor selectivity. In this work, we present a practical approach to estimate the Resolving Power of a sensory system, considering non-linear sensors and heteroscedastic sensor noise. We use the definition introduced by Shannon in the field of communication theory to quantify the number of symbols in a noisy environment, and its version adapted by Gardner and Barlett for chemical sensor systems. Our method combines dimensionality reduction and the use of algorithms to compute the convex hull of the empirical data to estimate the data volume in the sensor response space. We validate our methodology with synthetic data and with actual data captured with temperature-modulated MOX gas sensors. Unlike other methodologies, our method does not require the intrinsic dimensionality of the sensor response to be smaller than the dimensionality of the input space. Moreover, our method circumvents the problem to obtain the sensitivity matrix, which usually is not known. Hence, our method is able to successfully compute the Resolving Power of actual chemical sensor arrays. We provide a relevant figure of merit, and a methodology to calculate it, that was missing in the literature to benchmark broad-response gas sensor arrays.

JTD Keywords: Gas sensor array, MOX sensors, Resolving Power, Sensor resolution, Dimensionality reduction, Machine olfaction


Fonollosa, Jordi, Solórzano, Ana, Marco, Santiago, (2018). Chemical sensor systems and associated algorithms for fire detection: A review Sensors 18, (2), 553

Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm responses than conventional smoke-based fire detectors. Moreover, since it is known that most casualties in fires are produced from toxic emissions rather than actual burns, gas-based fire detection could provide an additional level of safety to building occupants. In this line, since the 2000s, electrochemical cells for carbon monoxide sensing have been incorporated into fire detectors. Even systems relying exclusively on gas sensors have been explored as fire detectors. However, gas sensors respond to a large variety of volatiles beyond combustion products. As a result, chemical-based fire detectors require multivariate data processing techniques to ensure high sensitivity to fires and false alarm immunity. In this paper, we the survey toxic emissions produced in fires and defined standards for fire detection systems. We also review the state of the art of chemical sensor systems for fire detection and the associated signal and data processing algorithms. We also examine the experimental protocols used for the validation of the different approaches, as the complexity of the test measurements also impacts on reported sensitivity and specificity measures. All in all, further research and extensive test under different fire and nuisance scenarios are still required before gas-based fire detectors penetrate largely into the market. Nevertheless, the use of dynamic features and multivariate models that exploit sensor correlations seems imperative

JTD Keywords: Fire detection, Gas sensor, Pattern recognition, Sensor fusion, Machine learning, Toxicants, Carbon monoxide, Hydrogen cyanide, Standard test fires, Transducers, Smoke


Burgués, J., Marco, S., (2018). Low power operation of temperature-modulated metal oxide semiconductor gas sensors Sensors 18, (2), 339

Mobile applications based on gas sensing present new opportunities for low-cost air quality monitoring, safety, and healthcare. Metal oxide semiconductor (MOX) gas sensors represent the most prominent technology for integration into portable devices, such as smartphones and wearables. Traditionally, MOX sensors have been continuously powered to increase the stability of the sensing layer. However, continuous power is not feasible in many battery-operated applications due to power consumption limitations or the intended intermittent device operation. This work benchmarks two low-power, duty-cycling, and on-demand modes against the continuous power one. The duty-cycling mode periodically turns the sensors on and off and represents a trade-off between power consumption and stability. On-demand operation achieves the lowest power consumption by powering the sensors only while taking a measurement. Twelve thermally modulated SB-500-12 (FIS Inc. Jacksonville, FL, USA) sensors were exposed to low concentrations of carbon monoxide (0–9 ppm) with environmental conditions, such as ambient humidity (15–75% relative humidity) and temperature (21–27 ◦C), varying within the indicated ranges. Partial Least Squares (PLS) models were built using calibration data, and the prediction error in external validation samples was evaluated during the two weeks following calibration. We found that on-demand operation produced a deformation of the sensor conductance patterns, which led to an increase in the prediction error by almost a factor of 5 as compared to continuous operation (2.2 versus 0.45 ppm). Applying a 10% duty-cycling operation of 10-min periods reduced this prediction error to a factor of 2 (0.9 versus 0.45 ppm). The proposed duty-cycling powering scheme saved up to 90% energy as compared to the continuous operating mode. This low-power mode may be advantageous for applications that do not require continuous and periodic measurements, and which can tolerate slightly higher prediction errors.

JTD Keywords: Smartphone, Metal-oxide semiconductor, Gas sensor, Low power, Temperature-modulation, Interferences


Burgués, Javier, Hernandez, Victor, Lilienthal, Achim J., Marco, Santiago, (2018). 3D Gas distribution with and without artificial airflow: An experimental study with a grid of metal oxide semiconductor gas sensors Proceedings EUROSENSORS 2018 , MDPI (Graz, Austria) 2, (13), 911

Gas distribution modelling can provide potentially life-saving information when assessing the hazards of gaseous emissions and for localization of explosives, toxic or flammable chemicals. In this work, we deployed a three-dimensional (3D) grid of metal oxide semiconductor (MOX) gas sensors deployed in an office room, which allows for novel insights about the complex patterns of indoor gas dispersal. 12 independent experiments were carried out to better understand dispersion patters of a single gas source placed at different locations of the room, including variations in height, release rate and air flow profiles. This dataset is denser and richer than what is currently available, i.e., 2D datasets in wind tunnels. We make it publicly available to enable the community to develop, validate, and compare new approaches related to gas sensing in complex environments.

JTD Keywords: MOX, Metal oxide, Flow visualization, Gas sensors, Gas distribution mapping, Sensor grid, 3D, Gas source localization, Indoor


Vouloutsi, Vasiliki, Halloy, José, Mura, Anna, Mangan, Michael, Lepora, Nathan, Prescott, T. J., Verschure, P., (2018). Biomimetic and Biohybrid Systems 7th International Conference, Living Machines 2018, Paris, France, July 17–20, 2018, Proceedings , Springer International Publishing (Lausanne, Switzerland) 10928, 1-551

This book constitutes the proceedings of the 7th International Conference on Biomimetic and Biohybrid Systems, Living Machines 2018, held in Paris, France, in July 2018. The 40 full and 18 short papers presented in this volume were carefully reviewed and selected from 60 submissions. The theme of the conference targeted at the intersection of research on novel life-like technologies inspired by the scientific investigation of biological systems, biomimetics, and research that seeks to interface biological and artificial systems to create biohybrid systems.

JTD Keywords: Artificial neural network, Bio-actuators, Bio-robotics, Biohybrid systems, Biomimetics, Bipedal robots, Earthoworm-like robots, Robotics, Decision-making, Tactile sensing, Soft robots, Locomotion, Insects, Sensors, Actuators, Robots, Artificial intelligence, Neural networks, Motion planning, Learning algorithms


Zaffino, R. L., Mir, M., Samitier, J., (2017). Oligonucleotide probes functionalization of nanogap electrodes Electrophoresis , 38, (21), 2712-2720

Nanogap electrodes have attracted a lot of consideration as promising platform for molecular electronic and biomolecules detection. This is mainly for their higher aspect ratio, and because their electrical properties are easily accessed by current-voltage measurements. Nevertheless, application of standard current-voltages measurements used to characterize nanogap response, and/or to modify specific nanogap electrodes properties, represents an issue. Since the strength of electrical fields in nanoscaled devices can reach high values, even at low voltages. Here, we analyzed the effects induced by different methods of surface modification of nanogap electrodes, in test-voltage application, employed for the electrical detection of a desoxyribonucleic acid (DNA) target. Nanogap electrodes were functionalized with two antisymmetric oligo-probes designed to have 20 terminal bases complementary to the edges of the target, which after hybridization bridges the nanogap, closing the electrical circuit. Two methods of functionalization were studied for this purpose; a random self-assembling of a mixture of the two oligo-probes (OPs) used in the platform, and a selective method that controls the position of each OP at selected side of nanogap electrodes. We used for this aim, the electrophoretic effect induced on negatively charged probes by the application of an external direct current voltage. The results obtained with both functionalization methods where characterized and compared in terms of electrode surface covering, calculated by using voltammetry analysis. Moreover, we contrasted the electrical detection of a DNA target in the nanogap platform either in site-selective and in randomly assembled nanogap. According to our results, a denser, although not selective surface functionalization, is advantageous for such kind of applications.

JTD Keywords: Biosensor bioelectronics, DNA electrophoresis, Nanogap electrodes, Self-assembled monolayers, Site-selective deposition


Pomareda, V., Magrans, R., Jiménez-Soto, J., Martínez, D., Tresánchez, M., Burgués, J., Palacín, J., Marco, S., (2017). Chemical source localization fusing concentration information in the presence of chemical background noise Sensors 17, (4), 904

We present the estimation of a likelihood map for the location of the source of a chemical plume dispersed under atmospheric turbulence under uniform wind conditions. The main contribution of this work is to extend previous proposals based on Bayesian inference with binary detections to the use of concentration information while at the same time being robust against the presence of background chemical noise. For that, the algorithm builds a background model with robust statistics measurements to assess the posterior probability that a given chemical concentration reading comes from the background or from a source emitting at a distance with a specific release rate. In addition, our algorithm allows multiple mobile gas sensors to be used. Ten realistic simulations and ten real data experiments are used for evaluation purposes. For the simulations, we have supposed that sensors are mounted on cars which do not have among its main tasks navigating toward the source. To collect the real dataset, a special arena with induced wind is built, and an autonomous vehicle equipped with several sensors, including a photo ionization detector (PID) for sensing chemical concentration, is used. Simulation results show that our algorithm, provides a better estimation of the source location even for a low background level that benefits the performance of binary version. The improvement is clear for the synthetic data while for real data the estimation is only slightly better, probably because our exploration arena is not able to provide uniform wind conditions. Finally, an estimation of the computational cost of the algorithmic proposal is presented.

JTD Keywords: Machine olfaction, Odor robots, Chemical sensors, Bayesian inference


Burgues, J., Fonollosa, J., Marco, S., (2017). Discontinuously operated MOX sensors for low power applications IEEE Conference Publications ISOCS/IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) , IEEE (Montreal, Canada) , 1-3

Metal oxide semiconductor sensors are limited by their low selectivity, high power consumption and temporal drift. This paper proposes a novel discontinuous temperature modulation operation mode characterized by on-demand measurements and periodic warm-up cycles. The performance of two sets of FIS SB-500-12 sensors, one group continuously operated and the other group discontinuously operated, was compared in a scenario of carbon monoxide detection at low concentrations for five consecutive days. Results showed that the discontinuous operating mode moderately increased the prediction error and the limit of detection but was advantageous in terms of energy savings (up to 60% with respect to the continuous temperature modulation mode).

JTD Keywords: Discontinuous operation, Duty-cycling, Low power, MOX sensors, Temperature modulation


Solorzano, A., Fonollosa, J., Fernandez, L., Eichmann, J., Marco, S., (2017). Fire detection using a gas sensor array with sensor fusion algorithms IEEE Conference Publications ISOCS/IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) , IEEE (Montreal, Canada) , 1-3

Conventional fire alarms are based on smoke detection. Nevertheless, in some fire scenarios volatiles are released before smoke. Fire detectors based only on chemical sensors have already been proposed as they may provide faster response, but they are still prone to false alarms in the presence of nuisances. These systems rely heavily on pattern recognition techniques to discriminate fires from nuisances. In this context, it is important to test the systems according to international standards for fires and testing the system against a diversity of nuisances. In this work, we investigate the behavior of a gas sensor array coupled to sensor fusion algorithms for fire detection when exposed to standardized fires and several nuisances. Results confirmed the ability to detect fires (97% Sensitivity), although the system still produces a significant rate of false alarms (35%) for nuisances not presented in the training set.

JTD Keywords: Fire alarm, Gas sensor array, Machine Olfaction, Multisensor system, Sensor fusion


Camara, M. A., Castillo, Y., Blanco-Almazan, D., Estrada, L., Jane, R., (2017). MHealth tools for monitoring Obstructive Sleep Apnea patients at home: Proof-of-concept Engineering in Medicine and Biology Society (EMBC) 39th Annual International Conference of the IEEE , IEEE (Seogwipo, South Korea) , 1555-1558

Obstructive Sleep Apnea (OSA) is a sleep disorder that affects mainly the adult and elderly population. Due to the high percentage of patients who remain undiagnosed and untreated because of limitations of current diagnosis methods, the management of OSA is an important social, scientific and economic problem that will be difficult to be assumed by health systems. On the other hand, smartphone platforms (mHealth systems) are being considered as an innovative solution, thanks to the integration of the essential sensors to obtain clinically relevant parameters in the same device or in combination with wireless wearable devices.

JTD Keywords: Sleep apnea, Microphones, Monitoring, Sensors, Accelerometers, Biomedical monitoring, Band-pass filters


Fonollosa, J., Fernández, L., Gutiérrez-Gálvez, A., Huerta, R., Marco, S., (2016). Calibration transfer and drift counteraction in chemical sensor arrays using Direct Standardization Sensors and Actuators B: Chemical 236, 1044-1053

Inherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and prevented mass-production for some applications. Here, aiming at exploring calibration transfer between chemical sensor arrays, we exposed five twin 8-sensor detection units to different concentration levels of ethanol, ethylene, carbon monoxide, or methane. First, we built calibration models using data acquired with a master unit. Second, to explore the transferability of the calibration models, we used Direct Standardization to map the signals of a slave unit to the space of the master unit in calibration. In particular, we evaluated the transferability of the calibration models to other detection units, and within the same unit measuring days apart. Our results show that signals acquired with one unit can be successfully mapped to the space of a reference unit. Hence, calibration models trained with a master unit can be extended to slave units using a reduced number of transfer samples, diminishing thereby calibration costs. Similarly, signals of a sensing unit can be transformed to match sensor behavior in the past to mitigate drift effects. Therefore, the proposed methodology can reduce calibration costs in mass-production and delay recalibrations due to sensor aging. Acquired dataset is made publicly available.

JTD Keywords: Calibration transfer, Chemical sensors, Direct Standardization, Electronic nose, MOX sensors, Public dataset


Fernandez, L., Guney, S., Gutierrez-Galvez, A., Marco, S., (2016). Calibration transfer in temperature modulated gas sensor arrays Sensors and Actuators B: Chemical 231, 276-284

Abstract Shifts in working temperature are an important issue that prevents the successful transfer of calibration models from one chemical instrument to another. This effect is of special relevance when working with gas sensor arrays modulated in temperature. In this paper, we study the use of multivariate techniques to transfer the calibration model from a temperature modulated gas sensor array to another when a global change of temperature occurs. To do so, we built 12 identical master sensor arrays composed of three different types of commercial Figaro sensors and acquired a dataset of sensor responses to three pure substances (ethanol, acetone and butanone) dosed at 7 concentrations. The master arrays are then shifted in temperature (from −50 to 50 °C, ΔT = 10 °C) and considered as slave arrays. Data correction is performed for an increasing number of transfer samples with 4 different calibration transfer techniques: Direct Standardization, Piece-wise Direct Standardization, Orthogonal Signal Correction and Generalized Least Squares Weighting. In order to evaluate the performance of the calibration transfer, we compare the Root Mean Square Error of Prediction (RMSEP) of master and slave arrays, for each instrument correction. Best results are obtained from Piece-wise Direct standardization, which exhibits the lower RMSEP values after correction for the smaller number of transfer samples.

JTD Keywords: Calibration transfer, Gas sensor array, MOX, Temperature modulation


Huerta, R., Mosqueiro, T., Fonollosa, J., Rulkov, N.F., Rodríguez-Lujan, I., (2016). Online decorrelation of humidity and temperature in chemical sensors for continuous monitoring Chemometrics and Intelligent Laboratory Systems , 157, 169-176

A method for online decorrelation of chemical sensor signals from the effects of environmental humidity and temperature variations is proposed. The goal is to improve the accuracy of electronic nose measurements for continuous monitoring by processing data from simultaneous readings of environmental humidity and temperature. The electronic nose setup built for this study included eight metal-oxide sensors, temperature and humidity sensors with a wireless communication link to external computer. This wireless electronic nose was used to monitor the air for two years in the residence of one of the authors and it collected data continuously during 537 days with a sampling rate of 1 sample per second. To estimate the effects of variations in air humidity and temperature on the chemical sensors' signals, we used a standard energy band model for an n-type metal-oxide (MOX) gas sensor. The main assumption of the model is that variations in sensor conductivity can be expressed as a nonlinear function of changes in the semiconductor energy bands in the presence of external humidity and temperature variations. Fitting this model to the collected data, we confirmed that the most statistically significant factors are humidity changes and correlated changes of temperature and humidity. This simple model achieves excellent accuracy with a coefficient of determination R2 close to 1. To show how the humidity–temperature correction model works for gas discrimination, we constructed a model for online discrimination among banana, wine and baseline response. This shows that pattern recognition algorithms improve performance and reliability by including the filtered signal of the chemical sensors.

JTD Keywords: Electronic nose, Chemical sensors, Humidity, Temperature, Decorrelation, Wireless e-nose, MOX sensors, Energy band model, Home monitoring


Estrada, L., Torres, A., Sarlabous, L., Jané, R., (2016). Evaluating respiratory muscle activity using a wireless sensor platform Engineering in Medicine and Biology Society (EMBC) 38th Annual International Conference of the IEEE , IEEE (Orlando, USA) , 5769-5772

Wireless sensors are an emerging technology that allows to assist physicians in the monitoring of patients health status. This approach can be used for the non-invasive recording of the electrical respiratory muscle activity of the diaphragm (EMGdi). In this work, we acquired the EMGdi signal of a healthy subject performing an inspiratory load test. To this end, the EMGdi activity was captured from a single channel of electromyography using a wireless platform which was compared with the EMGdi and the inspiratory mouth pressure (Pmouth) recorded with a conventional lab equipment. From the EMGdi signal we were able to evaluate the neural respiratory drive, a biomarker used for assessing the respiratory muscle function. In addition, we evaluated the breathing movement and the cardiac activity, estimating two cardio-respiratory parameters: the respiratory rate and the heart rate. The correlation between the two EMGdi signals and the Pmouth improved with increasing the respiratory load (Pearson's correlation coefficient ranges from 0.33 to 0.85). The neural respiratory drive estimated from both EMGdi signals showed a positive trend with an increase of the inspiratory load and being higher in the conventional EMGdi recording. The respiratory rate comparison between measurements revealed similar values of around 16 breaths per minute. The heart rate comparison showed a root mean error of less than 0.2 beats per minute which increased when incrementing the inspiratory load. In summary, this preliminary work explores the use of wireless devices to record the muscle respiratory activity to derive several physiological parameters. Its use can be an alternative to conventional measuring systems with the advantage of being portable, lightweight, flexible and operating at low energy. This technology can be attractive for medical staff and may have a positive impact in the way healthcare is being delivered.

JTD Keywords: Biomedical monitoring, Electrodes, Medical services, Monitoring, Muscles, Wireless communication, Wireless sensor networks


Ziyatdinov, Andrey, Fonollosa, Jordi, Fernández, Luis, Gutiérrez-Gálvez, Agustín, Marco, Santiago, Perera, Alexandre, (2015). Data set from gas sensor array under flow modulation Data in Brief 3, 131-136

Abstract Recent studies in neuroscience suggest that sniffing, namely sampling odors actively, plays an important role in olfactory system, especially in certain scenarios such as novel odorant detection. While the computational advantages of high frequency sampling have not been yet elucidated, here, in order to motivate further investigation in active sampling strategies, we share the data from an artificial olfactory system made of 16 MOX gas sensors under gas flow modulation. The data were acquired on a custom set up featured by an external mechanical ventilator that emulates the biological respiration cycle. 58 samples were recorded in response to a relatively broad set of 12 gas classes, defined from different binary mixtures of acetone and ethanol in air. The acquired time series show two dominant frequency bands: the low-frequency signal corresponds to a conventional response curve of a sensor in response to a gas pulse, and the high-frequency signal has a clear principal harmonic at the respiration frequency. The data are related to the study in [1], and the data analysis results reported there should be considered as a reference point.

JTD Keywords: Gas sensor array, MOX sensor, Flow modulation, Early detection, Biomimetics, Respiration, Sniffing


Galán, T., Prieto-Simón, B., Alvira, M., Eritja, R., Götz, G., Bäuerle, P., Samitier, J., (2015). Label-free electrochemical DNA sensor using "click"-functionalized PEDOT electrodes Biosensors and Bioelectronics 74, 751-756

Here we describe a label-free electrochemical DNA sensor based on poly(3,4-ethylenedioxythiophene)-modified (PEDOT-modified) electrodes. An acetylene-terminated DNA probe, complementary to a specific "Hepatitis C" virus sequence, was immobilized onto azido-derivatized conducting PEDOT electrodes using "click" chemistry. DNA hybridization was then detected by differential pulse voltammetry, evaluating the changes in the electrochemical properties of the polymer produced by the recognition event. A limit of detection of 0.13. nM was achieved using this highly selective PEDOT-based genosensor, without the need for labeling techniques or microelectrode fabrication processes. These results are promising for the development of label-free and reagentless DNA hybridization sensors based on conducting polymeric substrates. Biosensors can be easily prepared using any DNA sequence containing an alkyne moiety. The data presented here reveal the potential of this DNA sensor for diagnostic applications in the screening of diseases, such as "Hepatitis C", and genetic mutations.

JTD Keywords: Azido-EDOT, Click chemistry, Differential pulse voltammetry, DNA biosensor, Electrochemistry, Hepatitis C virus


Ziyatdinov, Andrey, Fonollosa, Jordi, Fernánndez, Luis, Gutierrez-Gálvez, Agustín, Marco, Santiago, Perera, Alexandre, (2015). Bioinspired early detection through gas flow modulation in chemo-sensory systems Sensors and Actuators B: Chemical 206, 538-547

Abstract The design of bioinspired systems for chemical sensing is an engaging line of research in machine olfaction. Developments in this line could increase the lifetime and sensitivity of artificial chemo-sensory systems. Such approach is based on the sensory systems known in live organisms, and the resulting developed artificial systems are targeted to reproduce the biological mechanisms to some extent. Sniffing behaviour, sampling odours actively, has been studied recently in neuroscience, and it has been suggested that the respiration frequency is an important parameter of the olfactory system, since the odour perception, especially in complex scenarios such as novel odourants exploration, depends on both the stimulus identity and the sampling method. In this work we propose a chemical sensing system based on an array of 16 metal-oxide gas sensors that we combined with an external mechanical ventilator to simulate the biological respiration cycle. The tested gas classes formed a relatively broad combination of two analytes, acetone and ethanol, in binary mixtures. Two sets of low-frequency and high-frequency features were extracted from the acquired signals to show that the high-frequency features contain information related to the gas class. In addition, such information is available at early stages of the measurement, which could make the technique suitable in early detection scenarios. The full data set is made publicly available to the community.11 http://archive.ics.uci.edu/ml/datasets/Gas+sensor+array+under+flow+modulation.

JTD Keywords: Gas sensor array, MOX sensor, Flow modulation, Early detection, Biomimetics, Sniffing


Fonollosa, J., Sheik, S., Huerta, R., Marco, S., (2015). Reservoir computing compensates slow response of chemosensor arrays exposed to fast varying gas concentrations in continuous monitoring Sensors and Actuators B: Chemical 215, 618-629

Metal oxide (MOX) gas sensors arrays are a predominant technological choice to perform fundamental tasks of chemical detection. Yet, their use has been mainly limited to relatively controlled instrument configurations where the sensor array is placed within a closed measurement chamber. Usually, the experimental protocol is defined beforehand and it includes three stages: the array is first exposed to a gas reference, then to the gas sample, and finally to the reference again to recover the initial state. Such sampling procedure requires signal acquisition during the complete experimental protocol and usually delays the output prediction until the predefined measurement duration is complete. Due to the slow time response of chemical sensors, the completion of the measurement typically requires minutes. In this paper we propose the use of reservoir computing (RC) algorithms to overcome the slow temporal dynamics of chemical sensor arrays, allowing identification and quantification of chemicals of interest continuously and reducing measurement delays. We generated two datasets to test the ability of RC algorithms to provide accurate and continuous prediction to fast varying gas concentrations in real time. Both datasets - one generated with synthetic data and the other acquired from actual gas sensors - provide time series of MOX sensors exposed to binary gas mixtures where concentration levels change randomly over time. Our results show that our approach improves the time response of the sensory system and provides accurate predictions in real time, making the system specifically suitable for online monitoring applications. Finally, the collected dataset and developed code are made publicly available to the research community for further studies.

JTD Keywords: Chemical sensors, Continuous gas prediction, Electronic nose, Real-time detection, Reservoir computing


Fernandez, L., Marco, S., Gutierrez-Galvez, A., (2015). Robustness to sensor damage of a highly redundant gas sensor array Sensors and Actuators B: Chemical 218, 296-302

Abstract In this paper we study the role of redundant sensory information to prevent the performance degradation of a chemical sensor array for different distributions of sensor failures across sensor types. The large amount of sensing conditions with two different types of redundancy provided by our sensor array makes possible a comprehensive experimental study. Particularly, our sensor array is composed of 8 different types of commercial MOX sensors modulated in temperature with two redundancy levels: (1) 12 replicates of each sensor type for a total of 96 sensors and (2) measurements using 16 load resistors per sensors for a total of 1536 redundant measures per second. We perform two experiments to determine the performance degradation of the array with increasing number of damaged sensors in two different scenarios of sensor faults distributions across sensor types. In the first experiment, we characterize the diversity and redundancy of the array for increasing number of damaged sensors. To measure diversity and redundancy, we proposed a functional definition based on clustering of sensor features. The second experiment is devoted to determine the performance degradation of the array for the effect of faulty sensors. To this end, the system is trained to separate ethanol, acetone and butanone at different concentrations using a PCA–LDA model. Test set samples are corrupted by means of three different simulated types of faults. To evaluate the performance of the array we used the Fisher score as a measure of odour separability. Our results show that to exploit to the utmost the redundancy of the sensor array faulty sensory units have to be distributed uniformly across the different sensor types.

JTD Keywords: Gas sensor arrays, Sensor redundancy, Sensor diversity, Sensor faults aging, Sensor damage, MOX sensors, Large sensor arrays


Barreiros dos Santos, M., Azevedo, S., Agusil, J. P., Prieto-Simón, B., Sporer, C., Torrents, E., Juárez, A., Teixeira, V., Samitier, J., (2015). Label-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria Bioelectrochemistry , 101, 146-152

Abstract Here we describe the fabrication of a highly sensitive and label-free ITO-based impedimetric immunosensor for the detection of pathogenic bacteria Escherichia coli O157:H7. Anti-E. coli antibodies were immobilized onto ITO electrodes using a simple, robust and direct methodology. First, the covalent attachment of epoxysilane on the ITO surface was demonstrated by Atomic Force Microscopy and cyclic voltammetry. The immobilization of antibody on the epoxysilane layer was quantified by Optical Waveguide Lightmode Spectroscopy, obtaining a mass variation of 12 ng cm− 2 (0.08 pmol cm− 2). Microcontact printing and fluorescence microscopy were used to demonstrate the specific binding of E. coli O157:H7 to the antibody-patterned surface. We achieved a ratio of 1:500 Salmonella typhimurium/E. coli O157:H7, thus confirming the selectivity of the antibodies and efficiency of the functionalization procedure. Finally, the detection capacity of the ITO-based immunosensor was evaluated by Electrochemical Impedance Spectroscopy. A very low limit of detection was obtained (1 CFU mL− 1) over a large linear working range (10–106 CFU mL− 1). The specificity of the impedimetric immunosensor was also examined. Less than 20% of non-specific bacteria (S. typhimurium and E. coli K12) was observed. Our results reveal the applicability of ITO for the development of highly sensitive and selective impedimetric immunosensors.

JTD Keywords: E. coli O157:H7, Electrochemical Impedance Spectroscopy, Immunosensor, Indium tin oxide, Label-free detection


Pardo, W. A., Mir, M., Samitier, J., (2015). Signal enhancement in ultraflat electrochemical DNA biosensors Electrophoresis , 36, (16), 1905-1911

The ability of holding back the undesired molecules, but at the same time to provide the right distribution and orientation of the bioreceptors, are critical targets to reach an efficient hybridization and enhanced detection in electrochemical DNA biosensors. The main actors responsible of these key functions are the substrate of the sensor and the interface auto-assembled on it. In this paper we present the annealing as a method to improve commercial gold evaporated substrates for biosensor applications. The restructuring of granulated gold surface by means of annealing heating treatment leads to the formation of ultraflat gold lamellar terraces. The formation of terraces was characterized with scanning tunneling microscopy and optical interferometry. The performance of the sensor sensitivity on granular substrates and ultraflat substrates was studied, concerning the orientation and surface coverage of the bioreceptor interface applied in electrochemical biosensor. The hybridization efficiency of ferrocene-labeled DNA amplified by PCR was characterized with surface plasmon resonance and electrochemistry. The experimental results demonstrate that annealing process, positive influence on optical and voltammetric readings, due to a structured organization of the bioreceptors on the flat substrate, gaining more efficient immobilization and DNA hybridization. The results suggest the annealing as a powerful tool for improving gold substrates in biosensors applications.

JTD Keywords: Annealing ultraflat surfaces, DNA biosensor, DNA hybridization, Electrochemistry, Self-assembled monolayer


Fonollosa, J., Neftci, E., Huerta, R., Marco, S., (2015). Evaluation of calibration transfer strategies between Metal Oxide gas sensor arrays Procedia Engineering EUROSENSORS 2015 , Elsevier (Freiburg, Germany) 120, 261-264

Abstract Inherent variability of chemical sensors makes necessary individual calibration of chemical detection systems. This shortcoming has traditionally limited usability of systems based on Metal Oxide (MOX) sensor arrays and prevented mass-production for some applications. Here, aiming at exploring transfer calibration between electronic nose systems, we exposed five identical 8-sensor detection units to controlled gas conditions. Our results show that a calibration model provides more accurate predictions when the tested board is included in the calibration dataset. However, we show that previously built calibration models can be extended to other units using a reduced number of measurements. While baseline correction seems imperative for successful baseline correction, among the different tested strategies, piecewise direct standardization provides more accurate predictions.

JTD Keywords: Electronic nose, Calibration, MOX sensor, Machine Olfaction


Palleja, T., Balsa, R., Tresanchez, M., Moreno, J., Teixido, M., Font, D., Marco, S., Pomareda, V., Palacin, J., (2014). Corridor gas-leak localization using a mobile Robot with a photo ionization detector sensor Sensor Letters , 12, (6-7), 974-977

The use of an autonomous mobile robot to locate gas-leaks and air quality monitoring in indoor environments are promising tasks that will avoid risky human operations. However, these are challenging tasks due to the chaotic gas profile propagation originated by uncontrolled air flows. This paper proposes the localization of an acetone gas-leak in a 44 m-length indoor corridor with a mobile robot equipped with a PID sensor. This paper assesses the influence of the mobile robot velocity and the relative height of the PID sensor in the profile of the measurements. The results show weak influence of the robot velocity and strong influence of the relative height of the PID sensor. An estimate of the gas-leak location is also performed by computing the center of mass of the highest gas concentrations.

JTD Keywords: Gas source detection, LIDAR sensor, Mobile robot, PID sensor, SLAM, Acetone, Air quality, Gases, Indoor air pollution, Mobile robots, Robots, Air quality monitoring, Autonomous Mobile Robot, Gas sources, Indoor environment, Leak localization, LIDAR sensors, Profile propagation, SLAM, Ionization of gases


Tahirbegi, I. B., Mir, M., Schostek, S., Schurr, M., Samitier, J., (2014). In vivo ischemia monitoring array for endoscopic surgery Biosensors and Bioelectronics 61, 124-130

An array with all-solid-state, potentiometric, miniaturized sensors for pH and potassium was developed to be introduced into the stomach or other sectors of the digestive tract by means of flexible endoscopy. These sensors perform continuous and simultaneous measurement of extracellular pH and potassium. This detection seeks to sense ischemia in the gastric mucosa inside the stomach, an event indicative of local microvascular perfusion and tissue oxygenation status. Our array is proposed as a medical tool to identify the occurrence of the ischemia after gastrointestinal or gastroesophageal anastomosis. The stability and feasibility of the miniaturized working and reference electrodes integrated in the array were studied under in vitro conditions, and the behavior of the potassium and pH ion-selective membranes were optimized to work under acidic gastric conditions with high concentrations of HCl. The array was tested in vivo in pigs to measure the ischemia produced by clamping the blood flow into the stomach. Our results indicate that ischemic and reperfusion states can be sensed in vivo and that information on tissue damage can be collected by this sensor array. The device described here provides a miniaturized, inexpensive, and mass producible sensor array for detecting local ischemia caused by unfavorable anastomotic perfusion and will thus contribute to preventing anastomotic leakage and failure caused by tissue necrosis.

JTD Keywords: Endoscopy, Surgery, Tissue, Gastric anastomosis, Gastric conditions, Ion selective sensors, Ischemia, pH detection, Reference electrodes, Simultaneous measurement, Tissue oxygenation, Sensors


Urbán, P., Fernàndez-Busquets, X., (2014). Nanomedicine against malaria Current Medicinal Chemistry , 21, (5), 605-629

Malaria is arguably one of the main medical concerns worldwide because of the numbers of people affected, the severity of the disease and the complexity of the life cycle of its causative agent, the protist Plasmodium sp. The clinical, social and economic burden of malaria has led for the last 100 years to several waves of serious efforts to reach its control and eventual eradication, without success to this day. With the advent of nanoscience, renewed hopes have appeared of finally obtaining the long sought-after magic bullet against malaria in the form of a nanovector for the targeted delivery of antimalarial drugs exclusively to Plasmodium-infected cells. Different types of encapsulating structure, targeting molecule, and antimalarial compound will be discussed for the assembly of Trojan horse nanocapsules capable of targeting with complete specificity diseased cells and of delivering inside them their antimalarial cargo with the objective of eliminating the parasite with a single dose. Nanotechnology can also be applied to the discovery of new antimalarials through single-molecule manipulation approaches for the identification of novel drugs targeting essential molecular components of the parasite. Finally, methods for the diagnosis of malaria can benefit from nanotools applied to the design of microfluidic-based devices for the accurate identification of the parasite's strain, its precise infective load, and the relative content of the different stages of its life cycle, whose knowledge is essential for the administration of adequate therapies. The benefits and drawbacks of these nanosystems will be considered in different possible scenarios, including cost-related issues that might be hampering the development of nanotechnology-based medicines against malaria with the dubious argument that they are too expensive to be used in developing areas.

JTD Keywords: Dendrimers, Liposomes, Malaria diagnosis, Nanobiosensors, Nanoparticles, Plasmodium, Polymers, Targeted drug delivery


Zaffino, R. L., Mir, M., Samitier, J., (2014). Label-free detection of DNA hybridization and single point mutations in a nano-gap biosensor Nanotechnology 25, (10), 105501 (8)

We describe a conductance-based biosensor that exploits DNA-mediated long-range electron transport for the label-free and direct electrical detection of DNA hybridization. This biosensor platform comprises an array of vertical nano-gap biosensors made of gold and fabricated through standard photolithography combined with focused ion beam lithography. The nano-gap walls are covalently modified with short, anti-symmetric thiolated DNA probes, which are terminated by 19 bases complementary to both the ends of a target DNA strand. The nano-gaps are separated by a distance of 50nm, which was adjusted to fit the length of the DNA target plus the DNA probes. The hybridization of the target DNA closes the gap circuit in a switch on/off fashion, in such a way that it is readily detected by an increase in the current after nano-gap closure. The nano-biosensor shows high specificity in the discrimination of base-pair mismatching and does not require signal indicators or enhancing molecules. The design of the biosensor platform is applicable for multiplexed detection in a straightforward manner. The platform is well-suited to mass production, point-of-care diagnostics, and wide-scale DNA analysis applications.

JTD Keywords: Biosensor, DNA hybridization, Labelfree, Nanogap, Single nucleotide mutation


Marco, Santiago, (2014). The need for external validation in machine olfaction: emphasis on health-related applications Analytical and Bioanalytical Chemistry Springer Berlin Heidelberg 406, (16), 3941-3956

Over the last two decades, electronic nose research has produced thousands of research works. Many of them were describing the ability of the e-nose technology to solve diverse applications in domains ranging from food technology to safety, security, or health. It is, in fact, in the biomedical field where e-nose technology is finding a research niche in the last years. Although few success stories exist, most described applications never found the road to industrial or clinical exploitation. Most described methodologies were not reliable and were plagued by numerous problems that prevented practical application beyond the lab. This work emphasizes the need of external validation in machine olfaction. I describe some statistical and methodological pitfalls of the e-nose practice and I give some best practice recommendations for researchers in the field.

JTD Keywords: Chemical sensor arrays, Pattern recognition, Chemometrics, Electronic noses, Robustness, Signal and data processing


Bennetts, Victor, Schaffernicht, Erik, Pomareda, Victor, Lilienthal, Achim, Marco, Santiago, Trincavelli, Marco, (2014). Combining non selective gas sensors on a mobile robot for identification and mapping of multiple chemical compounds Sensors 14, (9), 17331-17352

In this paper, we address the task of gas distribution modeling in scenarios where multiple heterogeneous compounds are present. Gas distribution modeling is particularly useful in emission monitoring applications where spatial representations of the gaseous patches can be used to identify emission hot spots. In realistic environments, the presence of multiple chemicals is expected and therefore, gas discrimination has to be incorporated in the modeling process. The approach presented in this work addresses the task of gas distribution modeling by combining different non selective gas sensors. Gas discrimination is addressed with an open sampling system, composed by an array of metal oxide sensors and a probabilistic algorithm tailored to uncontrolled environments. For each of the identified compounds, the mapping algorithm generates a calibrated gas distribution model using the classification uncertainty and the concentration readings acquired with a photo ionization detector. The meta parameters of the proposed modeling algorithm are automatically learned from the data. The approach was validated with a gas sensitive robot patrolling outdoor and indoor scenarios, where two different chemicals were released simultaneously. The experimental results show that the generated multi compound maps can be used to accurately predict the location of emitting gas sources.

JTD Keywords: Environmental monitoring, Gas discrimination, Gas distribution mapping, Service robots, Open sampling systems, PID, Metal oxide sensors


Juanola-Feliu, E., Miribel-Català, P. L., Avilés, C. P., Colomer-Farrarons, J., González-Piñero, M., Samitier, J., (2014). Design of a customized multipurpose nano-enabled implantable system for in-vivo theranostics Sensors 14, (10), 19275-19306

The first part of this paper reviews the current development and key issues on implantable multi-sensor devices for in vivo theranostics. Afterwards, the authors propose an innovative biomedical multisensory system for in vivo biomarker monitoring that could be suitable for customized theranostics applications. At this point, findings suggest that cross-cutting Key Enabling Technologies (KETs) could improve the overall performance of the system given that the convergence of technologies in nanotechnology, biotechnology, micro&nanoelectronics and advanced materials permit the development of new medical devices of small dimensions, using biocompatible materials, and embedding reliable and targeted biosensors, high speed data communication, and even energy autonomy. Therefore, this article deals with new research and market challenges of implantable sensor devices, from the point of view of the pervasive system, and time-to-market. The remote clinical monitoring approach introduced in this paper could be based on an array of biosensors to extract information from the patient. A key contribution of the authors is that the general architecture introduced in this paper would require minor modifications for the final customized bio-implantable medical device.

JTD Keywords: Biocompatible, Biosensor, Biotelemetry, Implantable multi-sensor, Innovation, KET, Nanomedicine, Personalized medicine, Biotelemetry, Innovation, Medical nanotechnology, Biocompatible, Implantable system, In-vivo, KET, Multi sensor, Personalized medicines, Theranostics, Biosensors


Mir, M., Lugo, R., Tahirbegi, I. B., Samitier, J., (2014). Miniaturizable ion-selective arrays based on highly stable polymer membranes for biomedical applications Sensors 14, (7), 11844-11854

Poly(vinylchloride) (PVC) is the most common polymer matrix used in the fabrication of ion-selective electrodes (ISEs). However, the surfaces of PVC-based sensors have been reported to show membrane instability. In an attempt to overcome this limitation, here we developed two alternative methods for the preparation of highly stable and robust ion-selective sensors. These platforms are based on the selective electropolymerization of poly(3,4-ethylenedioxythiophene) (PEDOT), where the sulfur atoms contained in the polymer covalently interact with the gold electrode, also permitting controlled selective attachment on a miniaturized electrode in an array format. This platform sensor was improved with the crosslinking of the membrane compounds with poly(ethyleneglycol) diglycidyl ether (PEG), thus also increasing the biocompatibility of the sensor. The resulting ISE membranes showed faster signal stabilization of the sensor response compared with that of the PVC matrix and also better reproducibility and stability, thus making these platforms highly suitable candidates for the manufacture of robust implantable sensors.

JTD Keywords: Biomedicine, Electrochemistry, Endoscope, Implantable device, Ion-selective electrode (ISE) sensor, Ischemia, pH detection, Biocompatibility, Chemical sensors, Electrochemistry, Electrodes, Electropolymerization, Endoscopy, Functional polymers, Implants (surgical), Ion selective electrodes, Medical applications, Polyvinyl chlorides, Stabilization, Biomedical applications, Biomedicine, Implantable devices, Ion selective sensors, Ischemia, Membrane instability, pH detection, Poly(3 ,4 ethylenedioxythiophene) (PEDOT), Ion selective membranes


Tahirbegi, I. B., Alvira, M., Mir, M., Samitier, J., (2014). Simple and fast method for fabrication of endoscopic implantable sensor arrays Sensors 14, (7), 11416-11426

Here we have developed a simple method for the fabrication of disposable implantable all-solid-state ion-selective electrodes (ISE) in an array format without using complex fabrication equipment or clean room facilities. The electrodes were designed in a needle shape instead of planar electrodes for a full contact with the tissue. The needle-shape platform comprises 12 metallic pins which were functionalized with conductive inks and ISE membranes. The modified microelectrodes were characterized with cyclic voltammetry, scanning electron microscope (SEM), and optical interferometry. The surface area and roughness factor of each microelectrode were determined and reproducible values were obtained for all the microelectrodes on the array. In this work, the microelectrodes were modified with membranes for the detection of pH and nitrate ions to prove the reliability of the fabricated sensor array platform adapted to an endoscope.

JTD Keywords: Chemical sensors, Cyclic voltammetry, Electrochemistry, Endoscopy, Fabrication, Implants (surgical), Microelectrodes, Needles, Nitrates, Scanning electron microscopy, Biomedicine, Fabricated sensors, Fabrication equipment, Implantable devices, Implantable sensors, Optical interferometry, Planar electrode, Roughness factor, Ion selective electrodes


Sheik, S., Marco, S., Huerta, R., Fonollosa, J., (2014). Continuous prediction in chemoresisitive gas sensors using reservoir computing Procedia Engineering 28th European Conference on Solid-State Transducers (EUROSENSORS 2014) , Eurosensors (Brescia, Italy) 87, 843-846

Although Metal Oxide (MOX) sensors are predominant choices to perform fundamental tasks of chemical detection, their use has been mainly limited to relatively controlled scenarios where a gas sensor array is first exposed to a reference, then to the gas sample, and finally to the reference again to recover the initial state. In this paper we propose the use of MOX sensors along with Reservoir Computing algorithms to identify chemicals of interest. Our approach allows continuous gas monitoring in simple experimental setups without the requirement of acquiring recovery transient of the sensors, thereby making the system specifically suitable for online monitoring applications.

JTD Keywords: Chemical sensing, Reservoir computing, Gas sensors, Dynamic gas mixtures, Electronic nose


Fernandez, L., Gutierrez-Galvez, A., Marco, S., (2014). Robustness to sensor damage of a highly redundant gas sensor array Procedia Engineering 28th European Conference on Solid-State Transducers (EUROSENSORS 2014) , Eurosensors (Brescia, Italy) 87, 851-854

Abstract In this paper we study the role of redundant sensory information to prevent the performance degradation of a chemical sensor array as the number of faulty sensors increases. The large amount of sensing conditions with two different types of redundancy provided by our sensor array makes possible a comprehensive experimental study. Particularly, our sensor array is composed of 8 different types of commercial MOX sensors modulated in temperature with two redundancy levels: 1) 12 replicates of each sensor type for a total of 96 sensors, and 2) measurements using 16 load resistors per sensors for a total of 1536 redundant measures per second. The system is trained to identify ethanol, acetone and butanone using a PCA-LDA model. Test set samples are corrupted by means of three different simulated types of faults. To evaluate the tolerance of the array against sensor failure, the Fisher Score is used as a figure of merit for the corrupted test set samples projected on the PCA-LDA model.

JTD Keywords: Gas ensor arrays, sensor redundancy, MOX sensors, large sensor arrays.


Martínez, Dani, Pallejà, T., Moreno, Javier, Tresanchez, Marcel, Teixidó, M., Font, Davinia, Pardo, Antonio, Marco, Santiago, Palacín, Jordi, (2014). A mobile robot agent for gas leak source detection Advances in Intelligent Systems and Computing Trends in Practical Applications of Heterogeneous Multi-Agent Systems. The PAAMS Collection (ed. Bajo Perez, Javier, Corchado Rodríguez, Juan M., Mathieu, Philippe, Campbell, Andrew, Ortega, Alfonso, Adam, Emmanuel, Navarro, Elena M., Ahrndt, Sebastian, Moreno, Maríaa N., Julián, Vicente), Springer International Publishing 293, 19-25

This paper presents an autonomous agent for gas leak source detection. The main objective of the robot is to estimate the localization of the gas leak source in an indoor environment without any human intervention. The agent implements an SLAM procedure to scan and map the indoor area. The mobile robot samples gas concentrations with a gas and a wind sensor in order to estimate the source of the gas leak. The mobile robot agent will use the information obtained from the onboard sensors in order to define an efficient scanning path. This paper describes the measurement results obtained in a long corridor with a gas leak source placed close to a wall.

JTD Keywords: Gas detection, Mobile robot agent, Laser sensor, Self-localization


Juanola-Feliu, Esteve, Colomer-Farrarons, Jordi, Miribel-Català, Pere, González-Piñero, Manel, Samitier, Josep, (2014). Nano-enabled implantable device for glucose monitoring Implantable Bioelectronics (ed. Katz, Evgeny), Wiley-VCH Verlag GmbH & Co. KGaA (Weinheim, Germany) , 247-263

This chapter contains sections titled: * Introduction * Biomedical Devices for In Vivo Analysis * Conclusions and Final Recommendations * References

JTD Keywords: Technology transfer, Innovation management, Nanotechnology, Nanobiosensor, Diabetes, Biomedical device, Implantable biosensors


Gorostiza, Pau, Arosio, Daniele, Bregestovski, Piotr, (2013). Molecular probes and switches for functional analysis of receptors, ion channels and synaptic networks Frontiers in Molecular Neuroscience 6, (Article 48), 1-2

Gustavsson, J., Planell, J., Engel, E., (2013). Ion-selective electrodes to monitor osteoblast-like cellular influence on the extracellular concentration of calcium Journal of Tissue Engineering and Regenerative Medicine 7, (8), 609-620

In bone tissue engineering, the composition of the ionic extracellular environment (IEE) can determine both cellular fate and a biomaterial's development and performance. Therefore, precise control of the IEE and a perfect understanding of the dynamic changes that it can be subject to due to cellular activity is highly desired. To achieve this, we initially monitored how two standard osteoblast-like cell models that expressed either high or low alkaline phosphatase activity - SAOS-2 and MG63 cells, respectively - affected the extracellular concentrations of calcium and phosphate during long-term cultures. It was observed that cellular influence on the IEE varied greatly between the two models and could be linked to the capacity of cells to deposit calcium in the extracellular matrix. Miniaturized ion-selective electrodes that could allow for real-time monitoring of calcium in a minimally invasive way were then constructed. The electrodes were characterized in standard in vitro cell culture environments, prior to being successfully applied for periods of 24h, to record the dynamics of cell-induced deposition of calcium in the extracellular matrix, while using osteogenic media of either high or low concentrations of phosphate. As a result, this study provides the background and technological means for the non-destructive evaluation of the IEE in vitro and allows for the optimization and development of better models of bone tissue construction.

JTD Keywords: Extracellular ions, Ion-selective electrode, MG63, Mineralization, Osteoblasts, Saos-2, Sensor, Tissue engineering


Ziyatdinov, A., Diaz, E. Fernández, Chaudry, A., Marco, S., Persaud, K., Perera, A., (2013). A software tool for large-scale synthetic experiments based on polymeric sensor arrays Sensors and Actuators B: Chemical 177, 596-604

This manuscript introduces a software tool that allows for the design of synthetic experiments in machine olfaction. The proposed software package includes both, a virtual sensor array that reproduces the diversity and response of a polymer array and tools for data generation. The synthetic array of sensors allows for the generation of chemosensor data with a variety of characteristics: unlimited number of sensors, support of multicomponent gas mixtures and full parametric control of the noise in the system. The artificial sensor array is inspired from a reference database of seventeen polymeric sensors with concentration profiles for three analytes. The main features in the sensor data, like sensitivity, diversity, drift and sensor noise, are captured by a set of models under simplified assumptions. The generator of sensor signals can be used in applications related to test and benchmarking of signal processing methods, neuromorphic simulations in machine olfaction and educational tools. The software is implemented in R language and can be freely accessed.

JTD Keywords: Gas Sensor Array, Conducting Polymers, Electronic Nose, Sensor Simulation, Synthetic Dataset, Benchmark, Educational Tool


Fonollosa, Jordi, Fernérndez, Luis, Huerta, Ramón, Gutiérrez-Gálvez, Agustín, Marco, Santiago, (2013). Temperature optimization of metal oxide sensor arrays using Mutual Information Sensors and Actuators B: Chemical Elsevier 187, (0), 331-339

The sensitivity and selectivity of metal oxide (MOX) gas sensors change significantly when the sensors operate at different temperatures. While previous investigations have presented systematic approaches to optimize the operating temperature of a single MOX sensor, in this paper we present a methodology to select the optimal operating temperature of all the MOX sensors constituent of a gas sensor array based on the multivariate response of all the sensing elements. Our approach estimates a widely used Information Theory measure, the so-called Mutual Information (MI), which quantifies the amount of information that the state of one random variable (response of the gas sensor array) can provide from the state of another random variable representing the gas quality. More specifically, our methodology builds sensor models from experimental data to solve the technical problem of populating the joint probability distribution for the MI estimation. We demonstrate the relevance of our approach by maximizing the MI and selecting the best operating temperatures of a four-sensor array sampled at 94 different temperatures to optimize the discrimination task of ethanol, acetic acid, 2-butanone, and acetone. In addition to being applicable in principle to sensor arrays of any size, our approach gives precise information on the ability of the system to discriminate odors according to the temperature of the MOX sensors, for either the optimal set of temperatures or the temperatures that may render inefficient operation of the system itself.

JTD Keywords: MOX gas sensor, Temperature optimization, Limit of detection, Mutual Information, E-nose, Sensor array, Information Theory, Chemical sensing


Marco, S., Gutiérrez-Gálvez, A., Lansner, A., Martinez, D., Rospars, J. P., Beccherelli, R., Perera, A., Pearce, T., Vershure, P., Persaud, K., (2013). Biologically inspired large scale chemical sensor arrays and embedded data processing Proceedings of SPIE - The International Society for Optical Engineering Smart Sensors, Actuators, and MEMS VI , SPIE Digital Library (Grenoble, France) 8763, 1-15

Biological olfaction outperforms chemical instrumentation in specificity, response time, detection limit, coding capacity, time stability, robustness, size, power consumption, and portability. This biological function provides outstanding performance due, to a large extent, to the unique architecture of the olfactory pathway, which combines a high degree of redundancy, an efficient combinatorial coding along with unmatched chemical information processing mechanisms. The last decade has witnessed important advances in the understanding of the computational primitives underlying the functioning of the olfactory system. EU Funded Project NEUROCHEM (Bio-ICT-FET- 216916) has developed novel computing paradigms and biologically motivated artefacts for chemical sensing taking inspiration from the biological olfactory pathway. To demonstrate this approach, a biomimetic demonstrator has been built featuring a large scale sensor array (65K elements) in conducting polymer technology mimicking the olfactory receptor neuron layer, and abstracted biomimetic algorithms have been implemented in an embedded system that interfaces the chemical sensors. The embedded system integrates computational models of the main anatomic building blocks in the olfactory pathway: The olfactory bulb, and olfactory cortex in vertebrates (alternatively, antennal lobe and mushroom bodies in the insect). For implementation in the embedded processor an abstraction phase has been carried out in which their processing capabilities are captured by algorithmic solutions. Finally, the algorithmic models are tested with an odour robot with navigation capabilities in mixed chemical plumes.

JTD Keywords: Antennal lobes, Artificial olfaction, Computational neuroscience, Olfactory bulbs, Plume tracking, Abstracting, Actuators, Algorithms, Biomimetic processes, Chemical sensors, Conducting polymers, Data processing, Flavors, Odors, Robots, Smart sensors, Embedded systems


Fernandez, L., Gutierrez-Galvez, A., Marco, S., (2013). Multi-way analysis of diversity and redundancy factors in large MOX gas sensor data Metal Oxide-based Sensors 14th International Meeting on Chemical Sensors - IMCS 2012 , AMA Science Portal (Nuremberg, Germany) P2.07, 1279-1280

We propose the use of multi-way methods to analyze the contribution of diversity and redundancy to odor identification and concentration estimation in a large chemical sensor array. We use a chemical sensing system based on a large array of metal oxide sensors (MOX) and inspired on the diversity and redundancy of the olfactory epithelium. In order to analyze the role of diversity (different sensor type and temperature modulation) and redundancy (replicates of sensors and different load resistors) in odor quantification and discrimination tasks, we have acquired two datasets and modeled the data using multi-way techniques.

JTD Keywords: Artificial Olfaction, Large array, MOX gas sensor, Multi-way methods


Diéguez, Lorena, Caballero, David, Calderer, Josep, Moreno, Mauricio, Martínez, Elena, Samitier, Josep, (2012). Optical gratings coated with thin Si3N4 layer for efficient immunosensing by optical waveguide lightmode spectroscopy Biosensors , 2, (2), 114-126

New silicon nitride coated optical gratings were tested by means of Optical Waveguide Lightmode Spectroscopy (OWLS). A thin layer of 10 nm of transparent silicon nitride was deposited on commercial optical gratings by means of sputtering. The quality of the layer was tested by x-ray photoelectron spectroscopy and atomic force microscopy. As a proof of concept, the sensors were successfully tested with OWLS by monitoring the concentration dependence on the detection of an antibody-protein pair. The potential of the Si3N4 as functional layer in a real-time biosensor opens new ways for the integration of optical waveguides with microelectronics.

JTD Keywords: Silicon nitride, Optical gratings, Waveguide, Biosensor


Gustavsson, J., Ginebra, M. P., Planell, J., Engel, E., (2012). Electrochemical microelectrodes for improved spatial and temporal characterization of aqueous environments around calcium phosphate cements Acta Biomaterialia 8, (1), 386-393

Calcium phosphate compounds can potentially influence cellular fate through ionic substitutions. However, to be able to turn such solution-mediated processes into successful directors of cellular response, a perfect understanding of the material-induced chemical reactions in situ is required. We therefore report on the application of home-made electrochemical microelectrodes, tested as pH and chloride sensors, for precise spatial and temporal characterization of different aqueous environments around calcium phosphate-based biomaterials prepared from α-tricalcium phosphate using clinically relevant liquid to powder ratios. The small size of the electrodes allowed for online measurements in traditionally inaccessible in vitro environments, such as the immediate material-liquid interface and the interior of curing bone cement. The kinetic data obtained has been compared to theoretical sorption models, confirming that the proposed setup can provide key information for improved understanding of the biochemical environment imposed by chemically reactive biomaterials.

JTD Keywords: Calcium phosphate, Hydroxyapatite, Ion sorption, Iridium oxide, Sensors, Animals, Biocompatible Materials, Bone Cements, Calcium Phosphates, Cells, Cultured, Chlorides, Electrochemical Techniques, Gold, Hydrogen-Ion Concentration, Hydroxyapatites, Iridium, Materials Testing, Microelectrodes, Powders, Silver, Silver Compounds, Water


Tort, N., Salvador, J. P., Avino, A., Eritja, R., Comelles, J., Martinez, E., Samitier, J., Marco, M. P., (2012). Synthesis of steroid-oligonucleotide conjugates for a DNA site-encoded SPR immunosensor Bioconjugate Chemistry , 23, (11), 2183-2191

The excellent self-assembling properties of DNA and the excellent specificity of the antibodies to detect analytes of small molecular weight under competitive conditions have been combined in this study. Three oligonucleotide sequences (N(1)up, N(2)up, and N(3)up) have been covalently attached to three steroidal haptens (8, hG, and 13) of three anabolic-androgenic steroids (AAS), stanozolol (ST), tetrahydrogestrinone (THG), and boldenone (B), respectively. The synthesis of steroid oligonucleotide conjugates has been performed by the reaction of oligonucleotides carrying amino groups with carboxyl acid derivatives of steroidal haptens. Due to the chemical nature of the steroid derivatives, two methods for coupling the haptens and the ssDNA have been studied: a solid-phase coupling strategy and a solution-phase coupling strategy. Specific antibodies against ST, THG, and B have been used in this study to asses the possibility of using the self-assembling properties of the DNA to prepare biofunctional SPR gold chips based on the immobilization of haptens, by hybridization with the complementary oligonucleotide strands possessing SH groups previously immobilized. The capture of the steroid oligonucleotide conjugates and subsequent binding of the specific antibodies can be monitored on the sensogram due to variations produced on the refractive index on top of the gold chip. The resulting steroid oligonucleotide conjugates retain the hybridization and specific binding properties of oligonucleotides and haptens as demonstrated by thermal denaturation experiments and surface plasmon resonance (SPR).

JTD Keywords: Directed protein immobilization, Plasmon resonance biosensor, Self-assembled monolayers, Label-free, Serum samples, Assay, Immunoassays, Antibodies, Progress, Binding


Caballero, D., Martinez, E., Bausells, J., Errachid, A., Samitier, J., (2012). Impedimetric immunosensor for human serum albumin detection on a direct aldehyde-functionalized silicon nitride surface Analytica Chimica Acta 720, 43-48

In this work we report the fabrication and characterization of a label-free impedimetric immunosensor based on a silicon nitride (Si 3N 4) surface for the specific detection of human serum albumin (HSA) proteins. Silicon nitride provides several advantages compared with other materials commonly used, such as gold, and in particular in solid-state physics for electronic-based biosensors. However, few Si 3N 4-based biosensors have been developed; the lack of an efficient and direct protocol for the integration of biological elements with silicon-based substrates is still one of its the main drawbacks. Here, we use a direct functionalization method for the direct covalent binding of monoclonal anti-HSA antibodies on an aldehyde-functionalized Si-p/SiO 2/Si 3N 4 structure. This methodology, in contrast with most of the protocols reported in literature, requires less chemical reagents, it is less time-consuming and it does not need any chemical activation. The detection capability of the immunosensor was tested by performing non-faradaic electrochemical impedance spectroscopy (EIS) measurements for the specific detection of HSA proteins. Protein concentrations within the linear range of 10 -13-10 -7M were detected, showing a sensitivity of 0.128ΩμM -1 and a limit of detection of 10 -14M. The specificity of the sensor was also addressed by studying the interferences with a similar protein, bovine serum albumin. The results obtained show that the antibodies were efficiently immobilized and the proteins detected specifically, thus, establishing the basis and the potential applicability of the developed silicon nitride-based immunosensor for the detection of proteins in real and more complex samples.

JTD Keywords: Aldehyde, Electrochemical impedance spectroscopy, Human serum albumin, Immunosensor, Silicon nitride, Bovine serum albumins, Chemical reagents, Complex samples, Covalent binding, Detection capability, Electrochemical impedance, Electrochemical impedance spectroscopy measurements, Functionalizations, Human serum albumins, Impedimetric immunosensors, Label free, Limit of detection, Linear range, Protein concentrations, Silicon-based, Specific detection, Aldehydes


Baccar, Z.M., Caballero, D., Eritja, R., Errachid, A., (2012). Development of an impedimetric DNA-biosensor based on layered double hydroxide for the detection of long ssDNA sequences Electrochimica Acta 74, 123-129

DNA testing requires the development of sensitive and fast devices to measure the presence of nucleic acid sequences by DNA hybridization. In this paper, a simple and label-free DNA-biosensor has been investigated based on the detection of DNA hybridization on layered double hydroxide (LDH) nanomaterials with special emphasis on targeting long single stranded DNA sequences. First, the immobilization of a 20 bases long DNA probe on a thin layer of Mg2AlCO3 and Mg3AlCO3 LDH was studied. Then, DNA hybridization reaction was detected by means of Electrochemical Impedance Spectroscopy. The resulting biosensor showed a high sensitivity for the detection of 80 bases long DNA complementary sequences. The dynamic range was 18–270 ng/ml with a detection limit lower than 1.8 ng/ml.

JTD Keywords: DNA-biosensor, Nanomaterials, Layered double hydroxide, Self-assembly


Udina, S., Carmona, M., Pardo, A., Calaza, C., Santander, J., Fonseca, L., Marco, S., (2012). A micromachined thermoelectric sensor for natural gas analysis: Multivariate calibration results Sensors and Actuators B: Chemical 166-167, 338-348

The potential use of a micromachined thermopile based sensor device for analyzing natural gas is explored. The sensor consists of a thermally isolated hotplate which is heated by the application of a sequence of programmed voltages to an integrated heater. Once the hotplate reaches a stationary temperature, the thermopile provides a signal proportional to the hotplate temperature. These signals are processed in order to determine different natural gas properties. Sensor response is mainly dependent on the thermal conductivity of the surrounding gas at different temperatures. Seven predicted properties (normal density, Superior Heating Value, Wobbe index and the concentrations of methane, ethane, carbon dioxide and nitrogen) are calibrated against sensor signals by using multivariate regression, in particular Partial Least Squares. Experimental data have been used for calibration and validation. Results show property prediction capability with reasonable accuracy except for prediction of carbon dioxide concentration. A detailed uncertainty analysis is provided to better understand the metrological limits of the system. These results imply for the first time the possibility of designing unprecedented low-cost natural gas analyzers. The concept may be extended to other constrained gas mixtures (e.g. of a known number of components) to enable low-cost multicomponent gas analyzers.

JTD Keywords: Gas sensor, Natural gas, MEMS, Superior Heating Value, density, PLS


Kuphal, M., Mills, C.A., Korri-Youssoufi, H., Samitier, J., (2012). Polymer-based technology platform for robust electrochemical sensing using gold microelectrodes Sensors and Actuators B: Chemical 161, (1), 279-284

Rapid and inexpensive development of electrochemical sensors with good exploitation potential may be produced using a polymer as a substrate material. However, fabrication of polymer-based sensors is challenging. Using photolithography and etching of gold-coated poly(ethylene-2,6-naphthalate) (PEN), we have succeeded in fabricating disk-shaped and interdigitated microelectrodes (uEs). The electrodes have an excellent adhesion to the polymer and are encapsulated using a novel room-temperature process, applicable for low-cost, high-throughput fabrication. The PEN surface has been characterized in respect of wettability, surface energy and surface roughness. Finally, the electrodes give stable and reproducible electrochemical impedance spectroscopy and cyclic voltammetry responses, using the redox couple ferrocyanide and ruthenium hexamine. The results demonstrate the robustness and functionality of the polymer-based sensor platform with minimum feature sizes of 6 um.

JTD Keywords: Poly(ethylene naphthalate), Photolithography, Microelectrodes, Interdigitated electrodes, Electrochemical characterization, Electrochemical sensor


Juanola-Feliu, E., Colomer-Farrarons, J., Miribel-Català , P., Samitier, J., Valls-Pasola, J., (2012). Market challenges facing academic research in commercializing nano-enabled implantable devices for in-vivo biomedical analysis Technovation , 32, (3-4), 193-204

This article reports on the research and development of a cutting-edge biomedical device for continuous in-vivo glucose monitoring. This entirely public-funded process of technological innovation has been conducted at the University of Barcelona within a context of converging technologies involving the fields of medicine, physics, chemistry, biology, telecommunications, electronics and energy. The authors examine the value chain and the market challenges faced by in-vivo implantable biomedical devices based on nanotechnologies. In so doing, they trace the process from the point of applied research to the final integration and commercialization of the product, when the social rate of return from academic research can be estimated. Using a case-study approach, the paper also examines the high-tech activities involved in the development of this nano-enabled device and describes the technology and innovation management process within the value chain conducted in a University-Hospital-Industry-Administration-Citizens framework. Here, nanotechnology is seen to represent a new industrial revolution, boosting the biomedical devices market. Nanosensors may well provide the tools required for investigating biological processes at the cellular level in vivo when embedded into medical devices of small dimensions, using biocompatible materials, and requiring reliable and targeted biosensors, high speed data transfer, safely stored data, and even energy autonomy.

JTD Keywords: Biomedical device, Diabetes, Innovation management, Nanobiosensor, Nanotechnology, Research commercialization, Technology transfer, Academic research, Applied research, Barcelona, Biocompatible materials, Biological process, Biomedical analysis, Biomedical devices, Cellular levels, Converging technologies, Glucose monitoring, High-speed data transfer, Implantable biomedical devices, Implantable devices, In-vivo, Industrial revolutions, Innovation management, Medical Devices, Nanobiosensor, Rate of return, Research and development, Technological innovation, Value chains, Biological materials, Biomedical engineering, Biosensors, Commerce, Data transfer, Earnings, Engineering education, Glucose, Implants (surgical), Industrial research, Innovation, Medical problems, Nanosensors, Nanotechnology, Technology transfer, Equipment


Marco, S., Gutierrez-Galvez, A., (2012). Signal and data processing for machine olfaction and chemical sensing: A review IEEE Sensors Journal 12, (11), 3189-3214

Signal and data processing are essential elements in electronic noses as well as in most chemical sensing instruments. The multivariate responses obtained by chemical sensor arrays require signal and data processing to carry out the fundamental tasks of odor identification (classification), concentration estimation (regression), and grouping of similar odors (clustering). In the last decade, important advances have shown that proper processing can improve the robustness of the instruments against diverse perturbations, namely, environmental variables, background changes, drift, etc. This article reviews the advances made in recent years in signal and data processing for machine olfaction and chemical sensing.

JTD Keywords: Chemical sensors, Electronic nose, Intelligent sensors, Measurement techniques, Sensor arrays, Sensor systems


Azevedo, S., Diéguez, L., Carvalho, P., Carneiro, J. O., Teixeira, V., Martínez, Elena, Samitier, J., (2012). Deposition of ITO thin films onto PMMA substrates for waveguide based biosensing devices Journal of Nano Research , 17, 75-83

Biosensors' research filed has clearly been changing towards the production of multifunctional and innovative design concepts to address the needs related with sensitivity and selectivity of the devices. More recently, waveguide biosensors, that do not require any label procedure to detect biomolecules adsorbed on its surface, have been pointed out as one of the most promising technologies for the production of biosensing devices with enhanced performance. Moreover the combination of optical and electrochemical measurements through the integration of transparent and conducting oxides in the multilayer structures can greatly enhance the biosensors' sensitivity. Furthermore, the integration of polymeric substrates may bring powerful advantages in comparison with silicon based ones. The biosensors will have a lower production costs being possible to disposable them after use ("one use sensor chip"). This research work represents a preliminary study about the influence of substrate temperature on the overall properties of ITO thin films deposited by DC magnetron sputtering onto 0,5 mm thick PMMA sheets.

JTD Keywords: ITO thin films, PMMA sheets, Waveguide biosensing devices, Biosensing devices, Conducting oxides, Dc magnetron sputtering, Electrochemical measurements, Enhanced performance, Innovative design, ITO thin films, Multilayer structures, Overall properties, PMMA sheets, Polymeric substrate, Production cost, Sensor chips, Silicon-based, Substrate temperature, Biosensors, Deposition, Design, Film preparation, Optical multilayers, Thin films, Vapor deposition, Waveguides, Substrates


Amigo, L. E., Fernandez, Q., Giralt, X., Casals, A., Amat, J., (2012). Study of patient-orthosis interaction forces in rehabilitation therapies IEEE Conference Publications 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) , IEEE (Roma, Italy) , 1098-1103

The design of mechanical joints that kinematically behave as their biological counterparts is a challenge that if not addressed properly can cause inadequate forces transmission between robot and patient. This paper studies the interaction forces in rehabilitation therapies of the elbow joint. To measure the effect of orthosis-patient misalignments, a force sensor with a novel distributed architecture has been designed and used for this study. A test-bed based on an industrial robot acting as a virtual exoskeleton that emulates the action of a therapist has been developed and the interaction forces analyzed.

JTD Keywords: Force, Force measurement, Force sensors, Joints, Medical treatment, Robot sensing systems, Force sensors, Medical robotics, Patient rehabilitation, Biological counterparts, Distributed architecture, Elbow joint, Force sensor, Inadequate forces transmission, Industrial robot, Mechanical joints design, Orthosis-patient misalignments, Patient-orthosis interaction forces, Rehabilitation therapies, Robot, Test-bed, Virtual exoskeleton


Mir, Monica, Martinez-Rodriguez, Sergio, Castillo-Fernandez, Oscar, Homs-Corbera, Antoni, Samitier, Josep, (2011). Electrokinetic techniques applied to electrochemical DNA biosensors Electrophoresis , 32, (8), 811-821

Electrokinetic techniques are contact-free methods currently used in many applications, where precise handling of biological entities, such as cells, bacteria or nucleic acids, is needed. These techniques are based on the effect of electric fields on molecules suspended in a fluid, and the corresponding induced motion, which can be tuned according to some known physical laws and observed behaviours. Increasing interest on the application of such strategies in order to improve the detection of DNA strands has appeared during the recent decades. Classical electrode-based DNA electrochemical biosensors with combined electrokinetic techniques present the advantage of being able to improve the working electrode's bioactive part during their fabrication and also the hybridization yield during the sensor detection phase. This can be achieved by selectively manipulating, driving and directing the molecules towards the electrodes increasing the speed and yield of the floating DNA strands attached to them. On the other hand, this technique can be also used in order to make biosensors reusable, or reconfigurable, by simply inverting its working principle and pulling DNA strands away from the electrodes. Finally, the combination of these techniques with nanostructures, such as nanopores or nanochannels, has recently boosted the appearance of new types of electrochemical sensors that exploit the time-varying position of DNA strands in order to continuously scan these molecules and to detect their properties. This review gives an insight into the main forces involved in DNA electrokinetics and discusses the state of the art and uses of these techniques in recent years.

JTD Keywords: Electrochemical DNA biosensors, Lab-on-a-chip (LOC), Micro-total analysis systems (mu TAS), Nanopore


A. Mathur, P. Roca-Cusachs, O. M. Rossier, S. J. Wind, M. P. Sheetz, J. Hone, (2011). New approach for measuring protrusive forces in cells Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures , 29, (6), 06FA02

Pomareda, Victor, Marco, Santiago, (2011). Chemical plume source localization with multiple mobile sensors using bayesian inference under background signals Olfaction and Electronic Nose: Proceedings of the 14th International Symposium on Olfaction and Electronic Nose AIP Conference Proceedings (ed. Perena Gouma, SUNY Stony Brook), AIP (New York City, USA) 1362, (1), 149-150

This work presents the estimation of a likelihood map for the location of a source of chemical plume using multiple mobile sensors and Bayesian Inference. Previously described methods use a single sensor and just binary detections (concentrations above or below a certain threshold). The main contribution of this work is to extend previous proposals to use concentration information while at the same time being robust against the presence of background signals. The algorithm has two parts. The first part, concerning Adaptive Background Estimation, uses robust statistics measurements to estimate the background level despite the intermittent presence of high concentrations due to plume statistics. The second part of the algorithm estimates likelihood functions for background and for condition plus plume. Then, the algorithm sequentially builds a likelihood probability map for the location of the source. The algorithm allows the use of multiple mobile sensors. The simulation results demonstrate that our algorithm estimates better the source location and is much more robust in the presence of false alarms.

JTD Keywords: Sensors, Inference mechanisms, Probability, Simulation


Punter-Villagrasa, J., Colomer-Farrarons, J., Miribel-Catala, P., Puig-Vidal, M., Samitier, J., (2011). Discrete to full custom ASIC solutions for bioelectronic applications Proceedings of the SPIE - The International Society for Optical Engineering VLSI Circuits and Systems V , SPIE - The International Society for Optical Engineering (Prague, Czech Republic) 8067, 80670Q

This paper presents a first approach on multi-pathogen detection system for portable point-of-care applications on discrete electronics field. The main interest is focused on the development of custom built electronic solutions for bioelectronics applications, from discrete devices to ASICS solutions.

JTD Keywords: Application specific integrated circuits, Biomedical electronics, Biosensors


Colomer-Farrarons, Jordi , Miribel-Català, Pedro Luís, Samitier, Josep , (2011). Low-voltage µpower CMOS subcutaneous biomedical implantable device for true/false applications Biomedical Engineering IASTED International Conference Biomedical Engineering (Biomed 2011) (ed. Baumgartner, C.), ACTA Press (Innsbruck, Austria) Biomedical Engineering, 424-428

A ±1.2V / 350μW integrated front-end architecture for a true/false in-vivo subcutaneous detection device is presented. The detection is focused on using three electrodes amperometric sensors. The powering and AM transcutaneous communication are based on an inductively coupled link working at 13.56 MHz. A prototype device (5.5 mm x 29.5 mm) has been implemented and fully validated.

JTD Keywords: Implantable Device, Front-End architecture, Bioelectronics, Microelectronics Design, Biosensors


Gutierrez-Galvez, Agustin, Fernandez, Luis, Marco, Santiago, (2011). Study of sensory diversity and redundancy to encode for chemical mixtures Olfaction and Electronic Nose: Proceedings of the 14th International Symposium on Olfaction and Electronic Nose AIP Conference Proceedings (ed. Perena Gouma, SUNY Stony Brook), AIP (New York City, USA) 1362, (1), 147-148

Inspired by sensory diversity and redundancy at the olfactory epithelium, we have built a large chemical sensor array based on commercial MOX sensors. Different sensor families along with temperature modulation accounts for sensory diversity, whereas sensors of the same family combined with different load resistors provide redundancy to the system. To study the encoding of odor mixtures, a data collection consisting on the response of the array to 3 binary mixtures of ethanol, acetone, and butanone with 18 different concentration ratios is obtained.

JTD Keywords: Chemioception, Sensors, Data acquisition, Temperature measurement


Mir, M., (2011). Aptamers: The new biorecognition element for proteomic biosensing Biochemistry Research Updates (ed. Baginski, Simon J.), Nova Science Publishers, Inc (Hauppauge, USA) , -----

Aptamers are single stranded artificial nucleic acid ligands that can be generated against almost any kind of target, such as ions, metabolites aminoacids, drugs, toxins, proteins or whole cells. They are isolated from combinatorial libraries of synthetic nucleic acids by an iterative process of adsorption, recovery and amplification, know as SELEX (Systematic Evolution of Ligands by EXponential enrichment) process. Aptamers, the nucleic acid equivalent to antibodies, are easy to synthesise, is not required the use of animals for its synthesis, for this reason it can be developed again toxins and small molecules that do not produce immune response in animals and can be tuned for affinity in closer to assay conditions permitting recognition out of the physiological state. So, aptamers posses numerous advantages that make them preferred candidates as biorecognition elements. In view of the advantages and simple structure of aptamers, they have been used in a wide range of applications such as therapeutics, diagnosis, chromatography, environmental detection, among other.

JTD Keywords: Aptamers, Biosensors, Protein recognition


Colomer-Farrarons, Jordi, Miribel-Català, Pere LI., Rodríguez-Villarreal, A. Ivón, Samitier, Josep, (2011). Portable bio-devices: Design of electrochemical instruments from miniaturized to implantable devices New perspectives in biosensors technology and applications (ed. Andrea Serra, Pier), InTech (Rijeka, Croatia) Biomedical Engineering, 373-400

A biosensor is a detecting device that combines a transducer with a biologically sensitive and selective component. Biosensors can measure compounds present in the environment, chemical processes, food and human body at low cost if compared with traditional analytical techniques. This book covers a wide range of aspects and issues related to biosensor technology, bringing together researchers from 12 different countries. The book consists of 20 chapters written by 69 authors and divided in three sections: Biosensors Technology and Materials, Biosensors for Health and Biosensors for Environment and Biosecurity.

JTD Keywords: Bio-Devices, Electrochemical Instruments, Miniaturized Devices, Nanobiosensor


Prieto-Simón, B., Campà s, M., Marty, J. L., (2010). Electrochemical aptamer-based sensors Bioanalytical Reviews , 1, (2), 141-157

The valuable properties of aptamers, such as specificity, sensitivity, stability, cost-effectiveness and design flexibility, have favoured their use as biorecognition elements in biosensor development. These synthetic affinity probes can be developed for almost any target molecule, covering a wide range of applications in fields such as clinical diagnosis and therapy, environmental monitoring and food control. The combination of aptamers with high-performance electrochemical transducers, with their inherent high sensitivities, fast response times and simple equipment, has already provided several electrochemical aptamer-based sensors. Moreover, the small size and versatility of aptamers allow efficient immobilisations in high-density monolayers, an important feature towards miniaturisation and integration of compact electrochemical devices. This review describes the state-of-the-art of electrochemical aptamer-based sensors, entering into the details of the different strategies and types of electrochemical transduction and also considering their advantages when applied to the analysis of complex matrices.

JTD Keywords: Aptabeacon, Aptamer, Biosensor, Electrochemical detection, Redox label


Ziyatdinov, A., Marco, S., Chaudry, A., Persaud, K., Caminal, P., Perera, A., (2010). Drift compensation of gas sensor array data by common principal component analysis Sensors and Actuators B: Chemical 146, (2), 460-465

A new drift compensation method based on Common Principal Component Analysis (CPCA) is proposed. The drift variance in data is found as the principal components computed by CPCA. This method finds components that are common for all gasses in feature space. The method is compared in classification task with respect to the other approaches published where the drift direction is estimated through a Principal Component Analysis (PCA) of a reference gas. The proposed new method - employing no specific reference gas, but information from all gases -has shown the same performance as the traditional approach with the best-fitted reference gas. Results are shown with data lasting 7-months including three gases at different concentrations for an array of 17 polymeric sensors.

JTD Keywords: Gas sensor array, Drift, Common principal component, Analysis, Component correction, Electronic nose


Perera, A., Pardo, A., Barrettino, D., Hierlermann, A., Marco, S., (2010). Evaluation of fish spoilage by means of a single metal oxide sensor under temperature modulation Sensors and Actuators B: Chemical 146, (2), 477-482

In this paper the feasibility of using metal oxide gas sensor technology for evaluating spoilage process for sea bream (Sparus aurata) is explored. It is shown that a single sensor under temperature modulation is able to find a correlation with the fish spoilage process. Results are obtained in real frigorific storage conditions: that is, at low measurement temperatures with variations of relative humidity.

JTD Keywords: Gas sensors, Electronic nose, Spoilage process, Temperature modulation, Bream sparus-aurata, Electronic nose, Freshness, Quality, Sardines, Storage


Montoliu, I., Tauler, R., Padilla, M., Pardo, A., Marco, S., (2010). Multivariate curve resolution applied to temperature modulated metal oxide gas sensors Sensors and Actuators B: Chemical 145, (1), 464-473

Metal oxide (MOX) gas sensors have been widely used for years. Temperature modulation of gas sensors is as an alternative to increase their sensitivity and selectivity to different gas species. In order to enhance the extraction of useful information from this kind of signals, data processing techniques are needed. In this work, the use of self-modelling curve resolution techniques, in particular multivariate curve resolution-alternating least squares (MCR-ALS), is presented for the analysis of these signals. First, the performance of MCR in a synthetic dataset generated from temperature-modulated gas sensor response models has been evaluated, showing good results both in the resolution of gas mixtures and in the determination of concentration/sensitivity profiles. Secondly, experimental confirmation of previously obtained conclusions is attempted using temperature-modulated MOX sensors together with MCR-ALS for the analysis of carbon monoxide (CO) and methane (CH4) gas mixtures in dry air. Results allow confirming the possibility of using the proposed approach as a quantitative technique for gas mixtures analysis, and also reveal some limitations.

JTD Keywords: Temperature modulation, Multivariate curve resolution, MCR-ALS, Metal oxide sensors


Padilla, M., Perera, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2010). Drift compensation of gas sensor array data by orthogonal signal correction Chemometrics and Intelligent Laboratory Systems , 100, (1), 28-35

Drift is an important issue that impairs the reliability of gas sensing systems. Sensor aging, memory effects and environmental disturbances produce shifts in sensor responses that make initial statistical models for gas or odor recognition useless after a relatively short period (typically few weeks). Frequent recalibrations are needed to preserve system accuracy. However, when recalibrations involve numerous samples they become expensive and laborious. An interesting and lower cost alternative is drift counteraction by signal processing techniques. Orthogonal Signal Correction (OSC) is proposed for drift compensation in chemical sensor arrays. The performance of OSC is also compared with Component Correction (CC). A simple classification algorithm has been employed for assessing the performance of the algorithms on a dataset composed by measurements of three analytes using an array of seventeen conductive polymer gas sensors over a ten month period.

JTD Keywords: Gas sensor array, Drift, Orthogonal signal correction, Component correction, Cross-validation, Electronic nose, Data shift


Padilla, M., Perera, A., Montoliu, I., Chaudry, A., Persaud, K., Marco, S., (2010). Fault detection, identification, and reconstruction of faulty chemical gas sensors under drift conditions, using Principal Component Analysis and Multiscale-PCA Theoretical or Mathematical; Experimental The 2010 International Joint Conference on Neural Networks (IJCNN 2010) , IEEE, Piscataway, NJ, USA (Barcelona, Spain) , 7 pp.

Statistical methods like Principal Components Analysis (PCA) or Partial Least Squares (PLS) and multiscale approaches, have been reported to be very useful in the task of fault diagnosis of malfunctioning sensors for several types of faults. In this work, we compare the performance of PCA and Multiscale-PCA on a fault based on a change of sensor sensitivity. This type of fault affects chemical gas sensors and it is one of the effects of the sensor poisoning. These two methods will be applied on a dataset composed by the signals of 17 conductive polymer gas sensors, measuring three analytes at several concentration levels during 10 months. Therefore, additionally to performance's comparison, both method's stability along the time will be tested. The comparison between both techniques will be made regarding three aspects; detection, identification of the faulty sensors and correction of faulty sensors response.

JTD Keywords: Fault diagnosis, Gas sensors, Principal component analysis


Fernandez, L., Gutierrez-Galvez, A., Marco, S., (2010). Gas sensor array system inspired on the sensory diversity and redundancy of the olfactory epithelium Procedia Engineering Eurosensor XXIV Conference (ed. Jakoby, B., Vellekoop, M.J.), Elsevier Science BV (Linz, Austria) 5, (0), 25-28

This paper presents a chemical sensing system that takes inspiration from the combination of sensory diversity and redundancy at the olfactory epithelium to enhance the chemical information obtained from the odorants. The system is based on commercial MOS sensors and achieves, first, diversity trough different types of MOS along with modulation of their temperatures, and second redundancy including 12 MOS sensors for each type (12×8) combined with a high-speed multiplexing system that allows connecting 16 load resistors with each and every one of the 96 sensors in about two seconds. Exposition of the system to ethanol, ammonia, and acetone at different concentrations shows how the system is able to capture a large amount of information of the identity and the concentration of the odorant.

JTD Keywords: Gas sensor array, Biologically inspired system, Redundancy, Diversity, MOX sensors, Temperature modulation


Sanmarti, M., Iavicoli, P., Pajot-Augy, E., Gomila, G., Samitier, J., (2010). Human olfactory receptors immobilization on a mixed self assembled monolayer for the development of a bioelectronic nose Procedia Engineering (EUROSENSOR XXIV CONFERENCE) 24th Eurosensor Conference (ed. Jakoby, B., Vellekoop, M.J.), Elsevier Science (Linz, Austria) 5, 786-789

The present work focuses on the development of an immunosensing surface to build a portable olfactory system for the detection of complex mixture of odorants. Homogeneous cell derived vesicles expressing the olfactory receptors were produced and immobilized with efficiency onto a gold substrate through an optimized surface functionalization method.

JTD Keywords: Bioelectronic noses, Biosensors, Nanoproteoliposomes, Nanosomes, Olfactory receptors, SAMs


Caballero, D., Samitier, J., Bausells, J., Errachid, A., (2009). Direct patterning of anti-human serum albumin antibodies on aldehyde-terminated silicon nitride surfaces for HSA protein detection Small 5, (13), 1531-1534

Silicon nitride surfaces are modified with a triethoxysilane aldehyde self-assembled monolayer for the direct immobilization of monoclonal antibodies and the detection of human serum albumin proteins, without any activation requirements. Surface modification and the specific recognition interaction between the HSA protein and its associated antibody are studied by fluorescence microscopy and atomic force microscopy.

JTD Keywords: Aldehyde, Human serum albumin, Immunosensors, Microcontact printing, Silicon nitride


Mir, M., Homs, A., Samitier, J., (2009). Integrated electrochemical DNA biosensors for lab-on-a-chip devices Electrophoresis , 30, (19), 3386-3397

Analytical devices able to perform accurate and fast automatic DNA detection or sequencing procedures have many potential benefits in the biomedical and environmental fields. The conversion of biological or biochemical responses into quantifiable optical, mechanical or electronic signals is achieved by means of biosensors. Most of these transducing elements can be miniaturized and incorporated into lab-on-a-chip devices, also known as Micro Total Analysis Systems. The use of multiple DNA biosensors integrated in these miniaturized laboratories, which perform several analytical operations at the microscale, has many cost and efficiency advantages. Tiny amounts of reagents and samples are needed and highly sensitive, fast and parallel assays can be done at low cost. A particular type of DNA biosensors are the ones used based on electrochemical principles. These sensors offer several advantages over the popular fluorescence-based detection schemes. The resulting signal is electrical and can be processed by conventional electronics in a very cheap and fast manner. Furthermore, the integration and miniaturization of electrochemical transducers in a microsystem makes easier its fabrication in front of the most common currently used detection method. In this review, different electrochemical DNA biosensors integrated in analytical microfluidic devices are discussed and some early stage commercial products based on this strategy are presented.

JTD Keywords: DNA, Electrochemical DNA biosensors, Electrochemistry, Lab-on-a-chip, Micro Total Analysis systems, Field-effect transistors, Sequence-specific detection, Chemical-analysis systems, Solid-state nanopores, Carbon nanotubes, Microfluidic device, Electrical detection, Hybridization, Molecules, Sensor


Fonollosa, J., Carmona, M., Santander, J., Fonseca, L., Moreno, M., Marco, S., (2009). Limits to the integration of filters and lenses on thermoelectric IR detectors by flip-chip techniques Sensors and Actuators A: Physical , 149, (1), 65-73

In the trend towards miniaturization, a detector module containing multiple IR sensor channels is being built and characterized. In its final form it contains thermopiles, narrow band filters and Fresnel lenses. An important feature of such module is the assembly by flip-chip of the IR filters on top of the thermopiles. The performance of the filter-thermopile ensemble has been assessed by physical simulation and experiments and it has been optimized by the use of an empirically validated model. It has been found that integration of filters (or lenses) too close to the IR detector may lead to degraded performance due to thermal coupling. The impact and extent of this degradation has been thoroughly explored, being the main parameter the distance between the IR sensor and the filter. To avoid such detrimental effects a possibility is to set the device in vacuum conditions, obtaining an improved output response and avoiding the influence of the filters. Another way is to increase the solder joint height. Beyond a certain height, the filter is considered to be isolated from the thermopile.

JTD Keywords: Assembly, Infrared sensor, Infrared filter, Fresnel lenses, FEM simulation, Optimization


Colomer-Farrarons, J., Miribel-Catala, P. L., Samitier, J., Arundell, M., Rodriguez, I., (2009). Design of a miniaturized electrochemical instrument for in-situ O/sub 2/ monitoring Sensors and Signal Conditioning VLSI Circuits and Systems IV , SPIE (Desdren, Germany) 7363, 73630A

The authors are working toward the design of a device for the detection of oxygen, following a discrete and an integrated instrumentation implementation. The discrete electronics are also used for preliminary analysis, to confirm the validity of the conception of system, and its set-up would be used in the characterization of the integrated device, waiting for the chip fabrication. This paper presents the design of a small and portable potentiostat integrated with electrodes, which is cheap and miniaturized, which can be applied for on-site measurements for the simultaneous detection of O/sub 2/ and temperature in water systems. As a first approach a discrete PCB has been designed based on commercial discrete electronics and specific oxygen sensors. Dissolved oxygen concentration (DO) is an important index of water quality and the ability to measure the oxygen concentration and temperature at different positions and depths would be an important attribute to environmental analysis. Especially, the objective is that the sensor and the electronics can be integrated in a single encapsulated device able to be submerged in environmental water systems and be able to make multiple measurements. For our proposed application a small and portable device is developed, where electronics and sensors are miniaturized and placed in close proximity to each other. This system would be based on the sensors and electronics, forming one module, and connected to a portable notebook to save and analyze the measurements on-line. The key electronics is defined by the potentiostat amplifier, used to fix the voltage between the working (WE) and reference (RE) electrodes following an input voltage (Vin). Vin is a triangular signal, programmed by a LabView/sup c / interface, which is also used to represent the CV transfers. To obtain a smaller and compact solution the potentiostat amplifier has also been integrated defining a full custom ASIC amplifier, which is in progress, looking for a point-of-care device. These circuits have been designed with a 0.13 mu m technology from ST Microelectronics through the CMP-TIMA service.

JTD Keywords: Amplifiers, Application specific integrated circuits, Chemical sensors, Electrodes, Portable instruments, Temperature measurement, Water sources


Barreiros dos Santos, M., Sporer, C., Sanvicens, N., Pascual, N., Errachid, A., Martinez, E., Marco, M. P., Teixeira, V., Samiter, J., (2009). Detection of pathogenic Bacteria by Electrochemical Impedance Spectroscopy: Influence of the immobilization strategies on the sensor performance Procedia Chemistry 23rd Eurosensors Conference (ed. Brugger, J., Briand, D.), Elsevier Science, BV (Lausanne, Switzerland) 1, 1291-1294

Electrochemical impedance spectroscopy (EIS) is applied to detect pathogenic E. coli O157:H7 bacteria via a label free immunoassay-based detection method. Polyclonal anti-E.coli antibodies (PAb) are immobilized onto gold electrodes following two different strategies, via chemical bond formation between antibody amino groups and a carboxylic acid containing self-assembled molecular monolayer (SAM) and alternatively by linking a biotinylated anti-E. coli to Neutravidin on a mixed-SAM. Impedance spectra for sensors of both designs for increasing concentrations of E. coli are recorded in phosphate buffered saline (PBS). The Nyquist plots can be modeled with a Randle equivalent circuit, identifying the charge transfer resistance RCT as the relevant concentration dependent parameter. Sensors fabricated from both designs are able to detect very low concentration of E. coli with limits of detection as low as 10-100 cfu/ml. The influence of the different immobilization protocols on the sensor performance is evaluated in terms of sensitivity, dynamic range and resistance against nonspecific absorption.

JTD Keywords: Bacteria detection, Biosensors, E-coli, Impedance spectroscopy


Perera, A., Pardo, A., Barrettino, D., Hierlermann, A., Marco, S., (2009). Evaluation of fish spoilage by means of a single metal oxide sensor under temperature modulation Olfaction and Electronic Nose: Proceedings of the 13th International Symposium on Olfaction and Electronic Nose 13th International Symposium on Olfaction and Electronic Nose (ed. Pardo, M., Sberveglieri, G.), Amer Inst Physics (Brescia, Italy) 1137, 483-486

In this paper the feasibility of using metal oxide gas sensor technology for evaluating spoilage process for sea bream (Sparus Aurata) is explored. It is shown that a single sensor under temperature modulation is able to find a correlation with the fish spoilage process

JTD Keywords: Gas sensors, Electrochemical sensors, Chromatography


Marco, S., Gutierrez-Galvez, A., (2009). Recent developments in the application of biologically inspired computation to chemical sensing Olfaction Electronic Nose: Proceedings of the 13th International Symposium on Olfaction and Electronic Nose 13th International Symposium on Olfaction and the Electronic Nose (ed. Pardo, M., Sberveglieri, G.), Amer Inst Physics (Brescia, Italy) 1137, 151-154

Biological olfaction outperforms chemical instrumentation in specificity, response time, detection limit, coding capacity, time stability, robustness, size, power consumption, and portability. This biological function provides outstanding performance due, to a large extent, to the unique architecture of the olfactory pathway, which combines a high degree of redundancy, an efficient combinatorial coding along with unmatched chemical information processing mechanisms. The last decade has witnessed important advances in the understanding of the computational primitives underlying the functioning of the olfactory system. In this work, the state of the art concerning biologically inspired computation for chemical sensing will be reviewed. Instead of reviewing the whole body of computational neuroscience of olfaction, we restrict this review to the application of models to the processing of real chemical sensor data.

JTD Keywords: Computational Intelligence, Chemical Sensors


Perera, A., Rock, F., Montoliu, I., Weimar, U., Marco, S., (2009). Total solvent amount and human panel test predictions using gas sensor fast chromatography and multivariate linear and non-linear processing Olfaction and Electronic Nose: Proceedings of the 13th International Symposium on Olfaction and Electronic Nose 13th International Symposium on Olfaction and the Electronic Nose (ed. Pardo, M., Sberveglieri, G.), Amer Inst Physics (Brescia, Italy) 1137, 572-573

Data from a Gas Sensor based Chromatography instrument is used in order to replicate output from a human panel and the estimation of the total solvent amount measured by and FID device in a packaging application. The system is trained on different packaging sample properties and validated with unseen combinations of materials, varnishes and production processes. This contribution will show the difficulties on the prediction of the output of the human panel, and the success on the prediction of the total amount of solvent in the sample

JTD Keywords: Gas sensors, Solvent prediction


Baccar, Z. M., Caballero, D., Zine, N., Jaffrezic-Renault, N., Errachid, A., (2009). Development of urease/layered double hydroxides nanohybrid materials for the urea detection: Synthesis, analytical and catalytic characterizations Sensor Letters 6th Maghreb-Europe Meeting on Materials and Their Applications for Devices and Physical, Chemical and Biological Sensors , AMER SCIENTIFIC PUBLISHERS (Rabat, Morocco) 7, (5), 676-682

We developed new hybrid nanomaterials, urease/LDH (layered double hydroxides), for the urea detection. The LDH that were prepared by co-precipitation in constant pH and in ambient temperature are hydrotalcites (Mg2Al, Mg3Al) and zaccagnaite (Zn2Al and Zn3Al). The immobilization of urease in these various layered hybrid materials is realized by auto-assembly. The structures of hosted matrices were studied by X-ray diffraction, Absorbance Infrared spectroscopy in ATR mode and Atomic Force Microscopy (AFM). These techniques allowed the characterisation of the urease immobilization and its interactions with LDH chemical groups. The urease was adsorbed and its morphology was conserved in its new environment. Furthermore, the study of catalytic parameters of Urease/LDH biomembranes and of the kinetics reaction of urea hydrolysis shows a good conformation of the enzyme in hydrotalcite matrices and that the affinity is similar to free urease.

JTD Keywords: Ldh hybrid nanomaterials, Surface properties, Urea biosensors, Urease thin films


Guaus, E., Torrent-Burgues, J., Zine, N., Errachid, A., (2009). Glassy carbon electrode modified with a langmuir-blodgett film of a thiomacrocyclic ionophore for Cu(II) recognition Sensor Letters 6th Maghreb-Europe Meeting on Materials and Their Applications for Devices and Physical, Chemical and Biological Sensors , AMER SCIENTIFIC PUBLISHERS (Rabat, Morocco) 7, (5), 1006-1011

Nanometric films of a thiomacrocyclic ionophore, 4-phenyl-4-sulfide-11(1- oxodecyl)-1,7-dithia-11-aza-4-phosphacyclotetradecane (ThM), have been deposited on the surface of a Glassy Carbon Electrode (GCE) by the Langmuir-Blodgett (LB) technique. The films have been characterised by using AFM. The influence of these modified electrodes (GCE-ThM) on the reduction of Cu(II) ions has been investigated by using Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS), and its sensor response has been checked. The CV and EIS responses of LB films on GCE indicate that these ThM films are sensitive to Cu(II) ions. The analysis by EIS of the interference of some other cations, as Mg(II) and Co(II), shows that LB films of ThM can be used for specific Cu(II) sensing applications.

JTD Keywords: Cu(II) sensor, Cyclic voltammetry, Electrochemical impedance spectroscopy, Langmuir-blodgett films


Baccar, Z. M., Hidouri, S., El Bari, N., Jaffrezic-Renault, N., Errachid, A., Zine, N., (2009). Stable immobilization of anti-beta casein antibody onto layered double hydroxides materials for biosensor applications Sensor Letters 6th Maghreb-Europe Meeting on Materials and Their Applications for Devices and Physical, Chemical and Biological Sensors , AMER SCIENTIFIC PUBLISHERS (Rabat, Morocco) 7, (5), 647-655

This review presents the development of new kind of antibody/LDH (layered double hydroxides) hybrid nanomaterials for beta casein detection. The preparation method of the LDH is described. It is based on the co-precipitation of metallic salts in constant pH and temperature. The chosen LDH are hydrotalcites (Mg2AICO3, Mg3AICO3), Zaccagnaite: Zn2AICO3 and hydrocalumite: Ca 2AICI. Finally, the antibody is immobilized into the LDH materials using Layer-by-Layer method by autoassembly. In this work, we studied the surface properties of the prepared hybrid biomembranes using X-ray diffraction, Infrared spectroscopy in ATR mode and Atomic Force Microscopy (AFM). These techniques allow describing the antibody immobilization and its interactions with LDH. The antibody was adsorbed and its morphology was conserved in its new environment after more than 15 days continuously in PBS solution, promising a constant biosensor performance.

JTD Keywords: Anti β-casein antibody, Antibody immobilization, Ldh hybrid biomaterials, Urea biosensors


Gutierrez, A., Marco, S., (2009). Biologically inspired signal processing for chemical sensing Studies in Computational Intelligence GOSPEL Workshop on Bio-inspired Signal Processing (ed. Gutierrez, A., Marco, S.), Springer (Barcelona, Spain) -----, (188), -----

This 167-page book is volume 188 in the series 'Studies in computational intelligence.' This volume contain 9 extensive chapters written in English. This volume presents a collection of research advances in biologically inspired signal processing for chemical sensing. The olfactory system, and the gustatory system to a minor extent, has been taken in the last decades as a source of inspiration to develop artificial sensing systems. The recognition of odors by the olfactory system entails a number of signal processing functions such as preprocessing, dimensionality reduction, contrast enhancement, and classification. Using mathematical models to mimic the architecture of the olfactory system, these processing functions can be applied to chemical sensor signals. This book provides background on the olfactory system including a review on information processing in the insect olfactory system along with a proposed signal processing architecture based on the mammalian cortex. It also provides some bio-inspired approaches to process chemical sensor signals such as an olfactory mucosa to improve odor separation and a model of olfactory receptor neuron convergence to correlated sensor responses to an odor and his organoleptic properties. This book will useful to those working or studying in the areas of sensory reception and computational biology.

JTD Keywords: Nervous System (Neural Coordination), Computer Applications (Computational Biology), Sense Organs (Sensory Reception)


Cho, S., Castellarnau, M., Samitier, J., Thielecke, H., (2008). Dependence of impedance of embedded single cells on cellular behaviour Sensors 8, (2), 1198-1211

Non-invasive single cell analyses are increasingly required for the medical diagnostics of test substances or the development of drugs and therapies on the single cell level. For the non-invasive characterisation of cells, impedance spectroscopy which provides the frequency dependent electrical properties has been used. Recently, microfludic systems have been investigated to manipulate the single cells and to characterise the electrical properties of embedded cells. In this article, the impedance of partially embedded single cells dependent on the cellular behaviour was investigated by using the microcapillary. An analytical equation was derived to relate the impedance of embedded cells with respect to the morphological and physiological change of extracellular interface. The capillary system with impedance measurement showed a feasibility to monitor the impedance change of embedded single cells caused by morphological and physiological change of cell during the addition of DMSO. By fitting the derived equation to the measured impedance of cell embedded at different negative pressure levels, it was able to extrapolate the equivalent gap and gap conductivity between the cell and capillary wall representing the cellular behaviour.

JTD Keywords: Frequency-domain, Spectroscopy, Erythrocytes, Biosensor, Membrane, System


Udina, S., Pardo, A., Marco, S., Santander, J., Fonseca, L., (2008). Thermoelectric MEMS sensors for natural gas analysis Electronic Proceedings of the Seventh IEEE Sensors Conference 2008 Sensors, 2008 IEEE (ed. Frech, P., Siciliano, P.), IEEE (Lecce, Italy) , 1364-1367

T Multivariate data analysis techniques have been used for the first time in thermoelectric MEMS sensors in order to determine the composition of natural gas mixtures. Experimental measurements with different thermoelectric devices have been performed, the gathered data have been used to calibrate the sensor responses to four main components of natural gas: CH4, C2H6, N2 and CO2. Presence of the three first components was predicted with good accuracy while CO2 prediction was poor. Presented results indicate that thremoelectric sensors operated at different heater temperatures open the possibility of low-cost natural gas analysis.

JTD Keywords: Natural gas, Multivariate calibration, Thermal conductivity, Thermal sensor


Zazoua, A., Kherrat, R., Samar, M. H., Errachid, A., Jaffrezic-Renault, N., Bessueille, F., Leonard, D., (2008). Characterization of TBP containing polysiloxane membrane/insulator/semiconductor structures for hexavalent chromium detection Materials Science and Engineering: C-Biomimetic and Supramolecular Systems 5th Maghreb/Europe Meeting on Materials and Their Applications for Devices and Physical, Chemical and Biological Sensors (MADICA 2006) (ed. -----), Elsevier Science BV (Mahdia, Tunisia) 28, (5-6), 1014-1019

A hexavalent chromium-sensitive EMIS sensor (electrolyte membrane insulator semiconductor sensor) is prepared by deposition of a tributylphosphate (TBP) ionophore-containing siloprene membrane on a Si/SiO2/Si3N4 structure. The developed EMIS sensor was studied by means of impedance spectroscopy, capacitance-voltage, X-ray photoelectron spectrometry and FT-IR spectroscopy. From the flat-band shift of the EMIS structure, the nersntian response to the anionic species Cr2O7- was demonstrated. The linear range of detection is 10(-4) M to 10(-1) M and the detection limit is 10(-5) M. Sulfate and chloride anions are shown not to be interfering whereas carbonate ions present a pK(pot) equal to 0.19.

JTD Keywords: Hexavalent chromium, EMIS sensor, Tributylphosphate, Siloprene membrane


Castellarnau, M., Zine, N., Bausells, J., Madrid, C., Juarez, A., Samitier, J., Errachid, A., (2008). ISFET-based biosensor to monitor sugar metabolism in bacteria Materials Science & Engineering C 5th Maghreb-Europe Meeting on Materials and their Applicatons for Devices and Physical, Chemical and Biological Sensors (ed. -----), Elsevier Science (Mahdia, Tunisia) 28, (5-6), 680-685

We report the use of ion-selective field effect transistor devices (ISFETs) with an integrated pseudo-reference electrode for on-line monitoring of bacterial metabolism by monitoring of the pH variation. As a model we tested the ability of Lactobacillus strains to ferment sugars, producing lactic acid, which results in a decrease in pH in the suspension medium. We have tested and compared sugar uptake by L. sakei and a L. curvatus strains. The results obtained show that it is possible to distinguish between both types of Lactobacillus strains through their pattern of ribose uptake. The use of ISFETs represents a non-invasive methodology that can be used to monitor biological activity in a wide variety of systems.

JTD Keywords: Lactobacillus-sakei, Technology, Sensors, System, Growth, Cells, State, Meat


Barhoumi, H., Haddad, R., Maaref, A., Bausells, J., Bessueille, F., Leonard, D., Jaffrezic-Renault, N., Martelet, C., Zine, N., Errachid, A., (2008). Na+-implanted membrane for a capacitive sodium electrolyte-Insulator-Semiconductor microsensors Sensor Letters International Conference of Thermal, Mechanical and Multiphysics Simulation and Experiments in Microelectronics and Microsystems (ed. -----), Amer Scientific Publishers (Lombardy, Italy) 6, (1), 204-208

Ion implanted Insulator-Semiconductor (IS) sensor that specifically detects Na+ ions have been developed using ion implantation technique. Na+ ions were directly implanted with ion energies 30, 45, and 60 keV into the IS (oxidized Si3N4/Si3N4/SiO2/P-Si) structures previously covered with a thin aluminum layer. X-ray photoelectron spectroscopy (XPS) characterization shows that sodium and aluminum ions were implanted into the oxidized Si3N4 insulating layer surface. Their atomic percentage depending on energy, fluence of the implanted ion and of the annealing temperature. The sen sitivity of the ion-implanted IS structure for Na+ and of some interfering (K+, Li+, H+, and NH4+) ions was investigated using high frequency capacitance-voltage measurements. Under optimal i mplantation conditions such as energy, fluence and annealing temperature, the developed sodium microsensor demonstrates quasi-nernstian sensitivity (50 +/- 2 mV/pNa) in the concentration range from 10(-3.7) to 10(-1) M and high lifetime greater than 16 months without any loss of sensitivity.

JTD Keywords: Na+ microsensor, Ion implantation, XPS, C-V measurements


Mills, C. A., Pla, M., Martin, C., Lee, M., Kuphal, M., Sisquella, X., Martinez, E., Errachid, A., Samitier, J., (2007). Structured thin organic active layers and their use in electrochemical biosensors Measurement & Control , 40, (3), 88-91

Rodriguez, Segui, Bucior, I., Burger, M. M., Samitier, J., Errachid, A., Fernàndez-Busquets, X., (2007). Application of a bio-QCM to study carbohydrates self-interaction in presence of calcium Transducers '07 & Eurosensors Xxi, Digest of Technical Papers 14th International Conference on Solid-State Sensors, Actuators and Microsystems , IEEE (Lyon, France) 1-2, 1995-1998

In the past years, the quartz crystal microbalance (QCM) has been successfully applied to follow interfacial physical chemistry phenomena in a label free and real time manner. However, carbohydrate self adhesion has only been addressed partially using this technique. Carbohydrates play an important role in cell adhesion, providing a highly versatile form of attachment, suitable for biologically relevant recognition events in the initial steps of adhesion. Here, we provide a QCM study of carbohydrates' self-recognition in the presence of calcium, based on a species-specific cell recognition model provided by marine sponges. Our results show a difference in adhesion kinetics when varying either the calcium concentration (with a constant carbohydrate concentration) or the carbohydrate concentration (with constant calcium concentration).

JTD Keywords: Biomedical materials, Calcium, Cellular biophysics, Microbalances, Porous materials, Quartz, Surface chemistry/ bio-QCM, Carbohydrates self-interaction, Quartz crystal microbalance, Interfacial physical chemistry phenomena, Carbohydrate self adhesion, Biologically relevant recognition events, Marine sponges, Adhesion kinetics, Calcium concentration, Carbohydrate concentration, Biosensors, Biomedical materials, Surface chemistry, Cellular biophysics